Etonogestrel implant versus the standard 52 mg levonorgestrel IUD for long-term pregnancy prevention (completion of live #1337): both under 1 pregnancy per 100 woman-years for years, no demonstrated difference

Shelf #6039 · Women’s health

POSSIBLE — the etonogestrel implant and the standard 52 mg levonorgestrel IUD are comparably effective for long-term pregnancy prevention (every carded long-term rate is under 1 per 100 woman-years; no pregnancies in 444 implant woman-years of extended use versus 0.25–0.43 per 100 woman-years for the IUD in years 6–7), with no demonstrated difference and no head-to-head pregnancy trial

Stamped: 2026-11-28.

Evidence published: 2008–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How does the etonogestrel implant compare with the levonorgestrel IUD for long-term pregnancy prevention?

Balance of the evidence

POSSIBLE — this pack is a completion of live shelf #1337, which homes the etonogestrel implant against the low-dose 13.5 mg levonorgestrel intrauterine system on discontinuation and bleeding (Apter 2016). The slice built here is different: pregnancy prevention over years of use, against the standard 52 mg levonorgestrel IUD. No trial has randomised women to implant versus 52 mg IUD and counted pregnancies as the primary outcome, so the comparison is assembled from the one head-to-head cohort and each method's own long-term record. In the head-to-head extended-use cohort, implant users had no pregnancies in 444 woman-years of use beyond the approved duration, and 52 mg IUD users had failure rates of 0.25–0.43 per 100 woman-years in years 6–7 (McNicholas 2017). In the Contraceptive CHOICE cohort, intrauterine devices and implants pooled failed at 0.27 per 100 participant-years versus 4.55 for pills, patch or ring (Winner 2012). The 52 mg IUD's own 7-year randomised record gives a cumulative pregnancy rate of 0.5 per 100 women (Rowe 2016), and the implant's integrated trial analysis recorded no in-treatment pregnancies in 923 women over 24,100 cycles (Graesslin 2008). POSSIBLE: both methods prevent pregnancy at well under 1 per 100 woman-years for years; no difference between them has been demonstrated, and none could be detected without an enormous trial.

MeSH: Adolescent · Adult · Body Mass Index · Cohort Studies · Contraceptive Agents, Female · Desogestrel · Drug Implants · Female · Humans · Intrauterine Devices, Medicated · Levonorgestrel · Middle Aged · Pregnancy · Pregnancy, Unplanned · Prospective Studies · Time Factors · United States · United States Food and Drug Administration · Young Adult

Cards (5)

Card 1 — McNicholas 2017: head-to-head in extended use — no pregnancies in 444 woman-years on the implant; 52 mg levonorgestrel IUD failure 0.25–0.43 per 100 woman-years in years 6–7

Study: Prospective head-to-head cohort (extended use)

Population: Prospective cohort (Contraceptive CHOICE programme, St Louis) of women continuing their method beyond its approved duration: 291 etonogestrel implant users contributing 444.0 woman-years in years 4–5 of use, and 496 users of the 52 mg levonorgestrel intrauterine device contributing 696.9 woman-years in years 6–7 of use.

Summary: McNicholas 2017: head-to-head in extended use — no pregnancies in 444 woman-years on the implant; 52 mg levonorgestrel IUD failure 0.25–0.43 per 100 woman-years in years 6–7

Result: No pregnancies were documented in implant users during the 2 years beyond approved duration (failure rate 0 per 100 woman-years in year 4, one-sided 97.5% CI 0–1.48; and 0 in year 5, CI 0–2.65). Two pregnancies occurred in levonorgestrel IUD users: failure rate 0.25 per 100 woman-years in year 6 (95% CI 0.04–1.42) and 0.43 per 100 woman-years in year 7 (95% CI 0.08–2.39). Median serum etonogestrel remained above the 90 pg/mL ovulation threshold in all BMI classes through year 5.

Watch out: This cohort compares the methods in different windows of use (implant years 4–5 versus IUD years 6–7) among women who had already kept their method for years — a selected, satisfied population; it shows both stay highly effective, not that one beats the other within the approved durations.

Source: McNicholas C et al. Prolonged use of the etonogestrel implant and levonorgestrel intrauterine device: 2 years beyond Food and Drug Administration-approved duration. American journal of obstetrics and gynecology. 2017. PMID: 28147241. Registry ID: none in the record. MeSH: Adolescent · Adult · Body Mass Index · Cohort Studies · Contraceptive Agents, Female · Desogestrel · Drug Implants · Female · Humans · Intrauterine Devices, Medicated · Levonorgestrel · Middle Aged · Pregnancy · Pregnancy, Unplanned · Prospective Studies · Time Factors · United States · United States Food and Drug Administration · Young Adult

Card 2 — CHOICE 2012 (Winner): intrauterine devices and implants pooled failed at 0.27 per 100 participant-years, versus 4.55 for pills, patch or ring

Study: Prospective cohort (Contraceptive CHOICE Project)

Population: 7,486 participants in the Contraceptive CHOICE Project prospective cohort (St Louis), provided reversible contraception of their choice at no cost and followed for unintended pregnancy; long-acting methods were intrauterine devices (copper and levonorgestrel) and the etonogestrel implant.

Summary: CHOICE 2012 (Winner): intrauterine devices and implants pooled failed at 0.27 per 100 participant-years, versus 4.55 for pills, patch or ring

Result: 334 unintended pregnancies were identified. The failure rate among participants using pills, patch or ring was 4.55 per 100 participant-years, compared with 0.27 per 100 participant-years among participants using long-acting reversible contraception (adjusted hazard ratio 21.8, 95% CI 13.7 to 34.9). Rates of unintended pregnancy were similarly low among participants using depot medroxyprogesterone injection and those using an intrauterine device or implant, regardless of age, and among pill/patch/ring users under 21 the risk was almost twice that of older users.

Watch out: The headline rate pools intrauterine devices and the implant together — it proves the class performance both methods share, and cannot separate implant from IUD; women chose their own method, so the comparison with pills is observational.

Source: Winner B et al. Effectiveness of long-acting reversible contraception. The New England journal of medicine. 2012. PMID: 22621627. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Cohort Studies · Contraception · Contraceptive Devices, Female · Contraceptives, Oral · Drug Implants · Female · Humans · Injections · Intrauterine Devices · Medroxyprogesterone Acetate · Middle Aged · Multivariate Analysis · Pregnancy · Pregnancy, Unplanned · Transdermal Patch · Treatment Outcome · Young Adult

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Rowe 2016: the 52 mg levonorgestrel IUD's own 7-year record — cumulative pregnancy rate 0.5 per 100 women in a randomised trial of 1,884 users

Study: Randomised comparative trial, 7 years (WHO/HRP)

Population: 1,884 women with interval insertion of the 52 mg levonorgestrel intrauterine device (daily release 20 µg) in a 7-year open-label randomised comparative trial in 20 centres (11 in China), analysed with life tables; the comparator was the copper T380A IUD (1,871 women).

Summary: Rowe 2016: the 52 mg levonorgestrel IUD's own 7-year record — cumulative pregnancy rate 0.5 per 100 women in a randomised trial of 1,884 users

Result: The cumulative 7-year pregnancy rate with the levonorgestrel IUD was 0.5 (standard error 0.2) per 100 women, significantly lower than 2.5 (0.4) per 100 with the copper T380A. Cumulative method discontinuation at 7 years was higher with the levonorgestrel IUD (70.6 per 100) than the copper device (40.8 per 100), driven by removals for amenorrhea (26.1 per 100) and reduced bleeding (12.5 per 100).

Watch out: This trial benchmarks the standard levonorgestrel IUD against copper, not against the implant; it is carded as the IUD's own long-term efficacy record, and its population was parous women, with discontinuation patterns the authors note were culturally patterned.

Source: Rowe P et al. Safety and efficacy in parous women of a 52-mg levonorgestrel-medicated intrauterine device: a 7-year randomized comparative study with the TCu380A. Contraception. 2016. PMID: 26916172. Registry ID: none in the record. MeSH: Adult · Amenorrhea · Contraceptive Agents, Female · Device Removal · Female · Hemorrhage · Humans · Intrauterine Devices, Copper · Levonorgestrel · Patient Safety · Pregnancy · Pregnancy, Unplanned · Proportional Hazards Models · Time Factors

Card 4 — Graesslin 2008: the etonogestrel implant's integrated trial record — no in-treatment pregnancies in 923 women over 24,100 cycles (tested product: Implanon)

Study: Integrated analysis of 11 studies plus post-marketing surveillance

Population: Integrated efficacy analysis of 11 international studies of the etonogestrel-releasing subdermal implant (Implanon, Organon, part of Schering-Plough — the tested product named in the publication), including 923 non-breastfeeding women exposed for 24,100 cycles, plus nine years of marketing experience (1998–2007).

Summary: Graesslin 2008: the etonogestrel implant's integrated trial record — no in-treatment pregnancies in 923 women over 24,100 cycles (tested product: Implanon)

Result: No in-treatment or pretreatment pregnancies were reported in the integrated trial analysis. Over nine years of marketing, the overall pregnancy rate was 0.049 per 100 implants sold (estimated Pearl Index 0.031 counting all reported pregnancies), and 0.010 per 100 implants sold (estimated Pearl Index 0.006) counting only contraceptive method failures. Fifty post-treatment pregnancies were reported, six within 14 days of removal, showing fertility returns quickly.

Watch out: An industry-linked integrated analysis (market data were provided by the manufacturer, Organon) with no comparator; marketing-experience Pearl Indices depend on spontaneous reporting and implants sold, so they flatter the method relative to trial conditions.

Source: Graesslin O et al. The contraceptive efficacy of Implanon: a review of clinical trials and marketing experience. The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception. 2008. PMID: 18330813. Registry ID: none in the record. MeSH: Adult · Clinical Trials as Topic · Contraceptive Agents, Female · Desogestrel · Female · Humans · Practice Guidelines as Topic · Product Surveillance, Postmarketing

Card 5 — Synthesis: both methods sit well under 1 pregnancy per 100 woman-years for years of use; the only head-to-head cohort found no implant pregnancies and 0.25–0.43 per 100 woman-years for the IUD in extended use — POSSIBLE

Study: Synthesis

Population: The carded evidence: one prospective head-to-head extended-use cohort (291 implant and 496 IUD users), one large prospective cohort pooling the methods (7,486 women), one 7-year randomised trial benchmarking the 52 mg IUD (1,884 users), and one integrated analysis of the implant's trials (923 women). Total carded participants exceed 11,000, so no small-N stamp labelling applies.

Summary: Synthesis: both methods sit well under 1 pregnancy per 100 woman-years for years of use; the only head-to-head cohort found no implant pregnancies and 0.25–0.43 per 100 woman-years for the IUD in extended use — POSSIBLE

Result: Every long-term rate carded is below 1 pregnancy per 100 woman-years: implant 0 per 100 woman-years in extended use and no in-treatment pregnancies across its integrated trials; 52 mg levonorgestrel IUD 0.5 per 100 women cumulatively over 7 years and 0.25–0.43 per 100 woman-years in years 6–7; the pooled long-acting rate in CHOICE was 0.27 per 100 participant-years. POSSIBLE: the etonogestrel implant and the standard levonorgestrel IUD are comparably effective for long-term pregnancy prevention, with no demonstrated difference — the evidence is cohort and single-method records, not a head-to-head pregnancy trial. Discontinuation and bleeding against the low-dose 13.5 mg system stay homed on live shelf #1337.

Watch out: At failure rates this low, 'no demonstrated difference' is the strongest honest claim: ruling out even a twofold difference would need a trial far larger than any run, so counselling should turn on bleeding, hormones and placement preference — the ground #1337 covers for the low-dose device.

Source: Synthesis of McNicholas C et al. American journal of obstetrics and gynecology. 2017 (PMID: 28147241); Winner B et al. The New England journal of medicine. 2012 (PMID: 22621627); Rowe P et al. Contraception. 2016 (PMID: 26916172); Graesslin O et al. The European journal of contraception & reproductive health care. 2008 (PMID: 18330813).