Automated insulin delivery in insulin-treated type 2 diabetes outpatients (completion of live #955 and #561): HbA1c 0.6 points better than usual delivery with CGM in the one randomised trial

Shelf #6054 · Diabetes, glucose & metabolism

POSSIBLE (benefit) — automated insulin delivery lowered HbA1c by 0.6 percentage points more than continued usual insulin delivery with CGM in the one randomised trial (13 weeks), with single-arm switch studies in the same direction and hypoglycaemia remaining low

Stamped: 2026-11-28.

Evidence published: 2023–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with type 2 diabetes on multiple daily insulin injections, does automated insulin delivery improve glucose control compared with injections plus continuous glucose monitoring?

Balance of the evidence

Completion: live shelf #955 already homes fully closed-loop delivery in type 2 diabetes in hospital inpatients and in one small outpatient crossover trial (Daly 2023, 28 randomised adults, not re-carded here), and live shelf #561 homes closed-loop therapy predominantly in type 1 diabetes. This shelf answers the uncovered slice — modern outpatient automated insulin delivery (AID) systems in insulin-treated type 2 diabetes, most participants previously on multiple daily injections, against continued usual insulin delivery with continuous glucose monitoring (CGM). The one randomised trial (Kudva 2025, 319 adults, 13 weeks) found HbA1c fell 0.6 percentage points more with AID than with continued pretrial insulin delivery plus CGM (adjusted difference −0.6, 95% CI −0.8 to −0.4), with time in range 14 percentage points higher. Two single-arm studies point the same way: in 305 adults (73% previously on multiple daily injections) HbA1c fell 0.8 points after switching to AID (Pasquel 2025), and in a 24-person feasibility study switching from injections HbA1c fell 1.3 points (Davis 2023). Hypoglycaemia stayed low in all three reports. POSSIBLE (benefit): the randomised evidence is a single 13-week trial, and the supporting studies have no concurrent control group, so the stamp is capped at POSSIBLE despite the consistent direction.

MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Blood Glucose · Diabetes Mellitus, Type 2 · Glycated Hemoglobin · Hypoglycemia · Hypoglycemic Agents · Insulin · Insulin Infusion Systems · Continuous Glucose Monitoring · Young Adult · Aged, 80 and over · Treatment Outcome

Cards (4)

Card 1 — Kudva 2025 (2IQP): in 319 adults with insulin-treated type 2 diabetes, automated insulin delivery cut HbA1c by 0.6 percentage points more than continued usual insulin delivery with CGM over 13 weeks

Study: Randomised controlled trial (2IQP, Kudva 2025)

Population: 319 adults with insulin-treated type 2 diabetes randomised 2:1 at multiple centres to an automated insulin delivery system or to continue their pretrial insulin-delivery method (control); both groups used continuous glucose monitoring. Primary outcome was HbA1c at 13 weeks.

Summary: Kudva 2025 (2IQP): in 319 adults with insulin-treated type 2 diabetes, automated insulin delivery cut HbA1c by 0.6 percentage points more than continued usual insulin delivery with CGM over 13 weeks

Result: HbA1c fell by 0.9 percentage points in the AID group (8.2% to 7.3%) and by 0.3 points in the control group (8.1% to 7.7%) — mean adjusted difference −0.6 percentage points (95% CI −0.8 to −0.4; P<0.001). Time in the target range 70–180 mg/dL rose from 48% to 64% with AID and from 51% to 52% in controls (mean difference 14 percentage points, 95% CI 11 to 17). CGM-measured hypoglycaemia was infrequent in both groups; one severe hypoglycaemia event occurred in the AID group.

Watch out: The control group continued whatever insulin delivery it was already using — mostly injections, but not exclusively multiple daily injections — and 13 weeks is short; the trial shows a glucose-control advantage, not effects on complications, weight or durability beyond one quarter.

Source: Kudva YC et al. A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes. The New England journal of medicine. 2025. PMID: 40105270. Registry ID: NCT05785832. MeSH: Adult · Aged · Female · Humans · Male · Middle Aged · Blood Glucose · Diabetes Mellitus, Type 2 · Glycated Hemoglobin · Hypoglycemia · Hypoglycemic Agents · Insulin · Insulin Infusion Systems · Continuous Glucose Monitoring · Young Adult · Aged, 80 and over · Treatment Outcome

Estimate type: adjusted estimate, as stated in the card.

Card 2 — Pasquel 2025: in 305 adults with type 2 diabetes (73% on multiple daily injections), switching to automated insulin delivery lowered HbA1c from 8.2% to 7.4% over 13 weeks — single-arm, no randomised comparator

Study: Single-arm prospective clinical trial (Pasquel 2025)

Population: 305 adults aged 18–75 with type 2 diabetes using insulin for at least 3 months at 21 US centres (73% on multiple daily injections, 21% basal insulin only, 6% already on a pump; 62% already using CGM), studied in a single-arm prospective trial: 14 days of standard therapy, then 13 weeks on the Omnipod 5 automated insulin delivery system (named as tested in the publication).

Summary: Pasquel 2025: in 305 adults with type 2 diabetes (73% on multiple daily injections), switching to automated insulin delivery lowered HbA1c from 8.2% to 7.4% over 13 weeks — single-arm, no randomised comparator

Result: HbA1c fell from 8.2% at baseline to 7.4% at 13 weeks (mean difference −0.8 percentage points, 95% CI −1.0 to −0.7; P<0.001 for superiority against baseline), and time in range 70–180 mg/dL rose from 45% to 66% (difference 20 points, 95% CI 18 to 22). Time below 54 mg/dL and below 70 mg/dL was non-inferior to standard therapy. There was 1 episode of severe hypoglycaemia and no diabetic ketoacidosis.

Watch out: With no concurrent control group, some of this improvement may reflect trial participation, CGM initiation in the 38% not previously using it, and regression to the mean — it corroborates the randomised trial's direction but cannot size the effect on its own.

Source: Pasquel FJ et al. Automated Insulin Delivery in Adults With Type 2 Diabetes: A Nonrandomized Clinical Trial. JAMA network open. 2025. PMID: 39951268. Registry ID: NCT05815342. MeSH: Humans · Diabetes Mellitus, Type 2 · Female · Middle Aged · Male · Insulin · Adult · Hypoglycemic Agents · Glycated Hemoglobin · Aged · Insulin Infusion Systems · Prospective Studies · Adolescent · Young Adult · Blood Glucose

Card 3 — Davis 2023: in 24 adults with type 2 diabetes switching from injections, 8 weeks of automated insulin delivery lowered HbA1c by 1.3 percentage points and raised time in range by 21.9 points

Study: Single-arm feasibility trial (Davis 2023)

Population: 24 adults with type 2 diabetes (mean age 61 years, baseline HbA1c 9.4%, diabetes duration 19 years) previously using basal-only or basal-bolus insulin injections, with or without CGM, in a multicentre outpatient feasibility trial: 2 weeks of standard therapy with CGM, then 8 weeks on the Omnipod 5 automated insulin delivery system (named as tested in the publication).

Summary: Davis 2023: in 24 adults with type 2 diabetes switching from injections, 8 weeks of automated insulin delivery lowered HbA1c by 1.3 percentage points and raised time in range by 21.9 points

Result: HbA1c fell by 1.3% ± 0.7% (P<0.0001) and time in target range rose by 21.9% ± 15.2% (P<0.0001) on AID versus standard therapy, with no significant change in total daily insulin dose or BMI. Time at or above 250 mg/dL fell by 16.9% ± 16.2%, while time below 54 mg/dL stayed near zero in both phases (median 0.0% vs 0.00%; P=0.45).

Watch out: Only 24 participants, 8 weeks of device use, and a before–after design in people selected for HbA1c of at least 8% — a proof-of-feasibility result whose size should not be quoted as the expected effect; the randomised trial above is the anchor.

Source: Davis GM et al. Safety and Efficacy of the Omnipod 5 Automated Insulin Delivery System in Adults With Type 2 Diabetes: From Injections to Hybrid Closed-Loop Therapy. Diabetes care. 2023. PMID: 36787903. Registry ID: none in the record. MeSH: Adult · Humans · Middle Aged · Aged · Diabetes Mellitus, Type 1 · Diabetes Mellitus, Type 2 · Glycated Hemoglobin · Blood Glucose Self-Monitoring · Hypoglycemic Agents · Insulin · Blood Glucose · Insulin, Regular, Human · Insulin Infusion Systems

Card 4 — Synthesis: outpatient automated insulin delivery improves glucose control in insulin-treated type 2 diabetes — one randomised trial, supported by two single-arm switch studies

Study: Synthesis

Population: The carded evidence: one 13-week randomised trial (319 adults), one large single-arm switch trial (305 adults) and one small feasibility study (24 adults) — 648 participants in total, so no small-N stamp labelling applies.

Summary: Synthesis: outpatient automated insulin delivery improves glucose control in insulin-treated type 2 diabetes — one randomised trial, supported by two single-arm switch studies

Result: The randomised comparison against continued usual insulin delivery with CGM showed an HbA1c advantage of −0.6 percentage points and 14 points more time in range for AID (Kudva 2025). Both uncontrolled switch studies found improvements of similar or larger size (HbA1c −0.8 and −1.3 points), and hypoglycaemia remained low throughout. The hospital and fully closed-loop evidence is homed on live shelf #955 and type 1 evidence on live shelf #561; neither is re-carded here. POSSIBLE (benefit): a single randomised trial programme caps the stamp, however consistent the direction.

Watch out: All carded follow-up is 13 weeks or less and every endpoint is a glucose metric; nothing here speaks to long-term complications, cost, or who among injection-treated patients benefits most.

Source: Synthesis of Kudva YC et al. The New England journal of medicine. 2025 (PMID: 40105270); Pasquel FJ et al. JAMA network open. 2025 (PMID: 39951268); Davis GM et al. Diabetes care. 2023 (PMID: 36787903).