Question
Do external hip protectors prevent hip fractures in older people at high risk?
Balance of the evidence
SPLIT — POSSIBLE in nursing or residential care; MAYBE (weak evidence) in the community: The arc of this literature runs from an early strikingly positive trial to later, larger nulls. Kannus 2000 found hip fractures at 21.3 vs 46.0 per 1000 person-years (relative hazard 0.4). The later individually randomised van Schoor trial found no difference (18 vs 20 fractures; hazard ratio 1.05). The Cochrane synthesis in its Parker 2005 form pooled a marginally significant reduction in nursing/residential care (relative risk 0.77, 95% CI 0.62 to 0.97, with significant heterogeneity) and no reduction in the community (1.16, 0.85 to 1.59); its 2014 update softened the care-setting estimate further (0.82, 0.67 to 1.00; absolute effect 11 fewer per 1000, CI from 20 fewer to 0) and confirmed little or no community effect (1.15, 0.84 to 1.58). Acceptance and long-term adherence were poor throughout. Both halves of the arc stay printed: the early positive result is not deleted, and it does not outrank the later nulls.
MeSH: Fractures, Bone/epidemiology/prevention & control · Frail Elderly · Hip Fractures/epidemiology/prevention & control · Orthopedic Equipment/adverse effects · Patient Compliance · Poisson Distribution · Risk
Cards (5)
Card 1 — Kannus 2000: the early positive trial — hip fracture rates 21.3 vs 46.0 per 1000 person-years with a hip protector
Study: Randomised controlled trial
Population: 1,801 ambulatory but frail elderly adults (1,409 women and 392 men; mean age 82 years), randomised in a 1:2 ratio to a group wearing an anatomically designed external hip protector or to a control group; follow-up continued until the end of the first full month after 62 hip fractures had occurred in the control group.
Summary: Kannus 2000: hip fracture rates 21.3 vs 46.0 per 1,000 person-years (relative hazard 0.4) — the early positive trial.
Result: During follow-up, 13 subjects in the hip-protector group had a hip fracture versus 67 in the control group — rates of 21.3 and 46.0 per 1000 person-years (relative hazard 0.4, 95% CI 0.2 to 0.8; P=0.008 — a relative figure, with the absolute rates beside it). Pelvic fractures were slightly but not significantly fewer on protectors (2 vs 12 subjects; relative hazard 0.4, 0.1 to 1.8), and other fractures were similar. Within the protector group, 4 subjects fractured while wearing the protector (among 1,034 falls) and 9 while not wearing it (among 370 falls) (relative hazard 0.2, 0.05 to 0.5).
Watch out: This is the first and most positive trial in the field, with a 1:2 allocation and an event-driven stopping rule; later larger trials (next card) did not reproduce it, and the within-group wearing comparison is not randomised.
Source: Kannus P et al. Prevention of hip fracture in elderly people with use of a hip protector. N Engl J Med. 2000 Nov 23;343(21):1506-1513. PMID: 11087879. Registry ID: none in the record's databank fields (pre-registration-era trial).
Card 2 — van Schoor 2003: the later, individually randomised trial found no effect — 18 vs 20 hip fractures, hazard ratio 1.05
Study: Randomised controlled trial
Population: 561 elderly persons aged 70 years or older with low bone density and high fall risk, living in apartment houses for the elderly, homes for the elderly and nursing homes in Amsterdam and surroundings, enrolled March 1999 to March 2001; mean follow-up 69.6 weeks; the abstract does not state mean age or sex mix.
Summary: van Schoor 2003: 18 vs 20 hip fractures (hazard ratio 1.05) — no effect in the later, individually randomised trial.
Result: Eighteen hip fractures occurred in the intervention group versus 20 in the control group; four intervention-group fractures occurred while a protector was being worn and at least four late at night or early in the morning. There was no significant difference in time to first hip fracture in univariate analysis (log-rank P=0.86) or multivariate analysis (hazard ratio 1.05, 95% CI 0.55 to 2.03). The per-protocol analysis in compliant participants was also non-significant (hazard ratio 0.77, 0.25 to 2.38). The authors conclude the hip protector studied was not effective in preventing hip fractures.
Watch out: Compliance was the field's recurring problem and this trial is no exception — but its intention-to-treat null in an individually randomised design is exactly the evidence that tempers Kannus, and this shelf prints both.
Source: van Schoor NM et al. Prevention of hip fractures by external hip protectors: a randomized controlled trial. JAMA. 2003 Apr 16;289(15):1957-1962. PMID: 12697798. Registry ID: none in the record's databank fields.
Card 3 — Parker Cochrane 2005: pooling gave a marginal reduction in care settings (relative risk 0.77) and none in the community (1.16)
Study: Cochrane systematic review and meta-analysis of randomised trials
Population: 15 included trials; pooling covered 11 trials in nursing or residential care settings (including 6 cluster-randomised studies) and 3 individually randomised trials with 5,135 community-dwelling participants; one further trial contributed compliance data only; the abstract does not state a pooled mean age or sex mix.
Summary: Parker Cochrane 2005: care settings pooled to a marginal relative risk 0.77 ; the community pooled to 1.16 — nothing.
Result: Pooling the care-setting trials showed a marginally statistically significant reduction in hip fracture incidence (relative risk 0.77, 95% CI 0.62 to 0.97), with significant statistical heterogeneity. Pooling the three individually randomised community trials showed no reduction (relative risk 1.16, 95% CI 0.85 to 1.59). There was no significant effect on pelvic or other fractures. No important adverse effects were reported, but compliance, particularly long term, was poor. The authors' conclusion: accumulating evidence casts some doubt on the effectiveness of providing hip protectors.
Watch out: The care-setting pooled estimate rests partly on cluster-randomised trials pooled on an exploratory basis, and heterogeneity was significant — it is a marginal pooled signal, not a settled effect.
Source: Parker MJ et al. Hip protectors for preventing hip fractures in older people. Cochrane Database Syst Rev. 2005 Jul 20;(3):CD001255. PMID: 16034859. Registry ID: none in the record's databank fields — this is a systematic review, not a single trial.
Card 4 — Cochrane update 2014 (Santesso): the care-setting estimate softened to 0.82 with a confidence interval touching 1.00; community effect little or none
Study: Cochrane systematic review and meta-analysis (update of the review carded above — same review, later version)
Population: 19 studies, nine cluster-randomised, including approximately 17,000 people (mean age range 78 to 86 years across studies); 14 studies (11,808 participants) in nursing or residential care settings and 5 trials (5,614 participants) in the community.
Summary: Santesso Cochrane 2014: the care-setting estimate softened to 0.82 [0.67 to 1.00]; the community stayed null.
Result: Pooling the care-setting studies found moderate-quality evidence for a small reduction in hip fracture risk (risk ratio 0.82, 95% CI 0.67 to 1.00), an absolute effect of 11 fewer people (95% CI, from 20 fewer to 0) per 1000 having a hip fracture when provided with hip protectors. In the community, pooling showed little or no effect (risk ratio 1.15, 95% CI 0.84 to 1.58; absolute effect two more per 1000, CI 2 fewer to 6 more). There was probably little or no effect on falls (rate ratio 1.02) or on fractures other than hip or pelvis (0.87); the pelvic-fracture risk ratio was 1.27 (0.78 to 2.08). Skin irritation and other adverse events while wearing protectors ranged from 0% to 5%, and adherence, particularly long term, was poor.
Watch out: This update supersedes the 2005 version's numbers where they differ; both are carded so the shelf shows the estimate moving as larger null trials accumulated. The care-setting confidence interval includes no effect.
Source: Santesso N et al. Hip protectors for preventing hip fractures in older people. Cochrane Database Syst Rev. 2014 Mar 31;2014(3):CD001255. PMID: 24687239. Registry ID: none in the record's databank fields — this is a systematic review, not a single trial.
Card 5 — Synthesis: early promise, later nulls — POSSIBLE in care settings, MAYBE (weak evidence) in the community
Study: Synthesis
Population: Synthesis of the cards above: Kannus 2000 (1,801 frail elderly adults), van Schoor 2003 (561 high-risk elderly people), and the Cochrane synthesis in its 2005 Parker version (15 trials) and 2014 Santesso update (19 studies, about 17,000 people).
Summary: Early promise, later nulls — POSSIBLE in care settings, MAYBE (weak evidence) in the community.
Result: The two-handed arc is the finding. Kannus's relative hazard of 0.4 was not reproduced by van Schoor (hazard ratio 1.05) or by the pooled community trials (risk ratio 1.15 in the 2014 update), while the pooled care-setting estimate shrank from 0.77 (2005) to 0.82 with a confidence interval reaching 1.00 (2014) as evidence accumulated. This shelf is therefore stamped POSSIBLE for nursing/residential care and MAYBE (weak evidence) for community use, with poor adherence printed as the practical barrier throughout. Falls-prevention exercise lives on Shelves #161 and #459 and fracture-preventing drugs on Shelf #91 — neither is re-carded here.
Watch out: Do not quote Kannus alone: on this shelf the early-positive trial and the later null trials are always presented together.
Source: Synthesis of Kannus P et al. N Engl J Med. 2000;343(21):1506-1513. PMID: 11087879; van Schoor NM et al. JAMA. 2003;289(15):1957-1962. PMID: 12697798; Parker MJ et al. Cochrane Database Syst Rev. 2005;(3):CD001255. PMID: 16034859; Santesso N et al. Cochrane Database Syst Rev. 2014;2014(3):CD001255. PMID: 24687239. Registry IDs as on the individual cards.