SourceMed · Shelf #6060 in the ask interface

Dexamethasone suppression test accuracy in adrenal incidentaloma: sensitive at 50 nmol/L, specificity limited and threshold-dependent — positives need verification

Shelf #6060 · Diabetes, glucose & metabolism

POSSIBLE (test-accuracy, observational evidence) — at the 50 nmol/L (about 1.8 µg/dL) cutoff the 1 mg overnight dexamethasone suppression test is a sensitive screen for autonomous cortisol secretion but with limited, threshold- and assay-dependent specificity; positive results need verification (dexamethasone level, ACTH pattern, repeat testing)

Stamped: 2026-11-28.

Evidence published: 2017–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with an adrenal incidentaloma, how accurate is the 1 mg overnight dexamethasone suppression test for autonomous cortisol secretion?

Balance of the evidence

Test-accuracy shelf. The honest headline is that accuracy here is threshold-dependent and partly circular: autonomous cortisol secretion (ACS) is itself defined by the post-dexamethasone cortisol value in the ESE/ENSAT guideline framework, so there is no independent gold standard against which the 1 mg overnight dexamethasone suppression test (DST) can be validated — the carded studies instead measure what the test does at the standard 50 nmol/L (about 1.8 µg/dL) cortisol cutoff. At that cutoff the test is sensitive but poorly specific: in a 165-patient incidentaloma cohort the overnight test performed no better than longer suppression protocols and the companion tests (late-night salivary cortisol, urinary free cortisol, DHEAS) discriminated poorly (Ueland 2020). Measuring the dexamethasone level itself reclassified about a fifth of false positives and improved specificity (Ueland 2017), and a suppressed ACTH after the test helps verify true non-suppression (sensitivity 75–81%, specificity 78–85% for inadequate suppression; Puvaneswaralingam 2021). Live shelf #1758 covers adrenalectomy for this condition, not test accuracy, and is not re-carded. POSSIBLE (test-accuracy, observational evidence): the 1 mg overnight DST at 50 nmol/L is a reasonable rule-out screen whose positive results are frequently false or borderline and need confirmatory context — assay, dexamethasone level, ACTH and repeat testing — before ACS is diagnosed.

MeSH: Adenoma · Adolescent · Adrenal Gland Neoplasms · Adult · Aged · Aged, 80 and over · Case-Control Studies · Chromatography, Liquid · Cortisone · Cushing Syndrome · Dexamethasone · Female · Humans · Hydrocortisone · Incidental Findings · Male · Middle Aged · Prospective Studies · Saliva · Tandem Mass Spectrometry · Young Adult

Cards (4)

Card 1 — Ueland 2020: in 165 incidentaloma patients, no companion test discriminated autonomous cortisol secretion well, and the 2-day suppression test added nothing over the 1 mg overnight test

Study: Diagnostic-accuracy cohort study (Ueland 2020)

Population: 165 patients with adrenal incidentalomas evaluated retrospectively with morning ACTH, late-night salivary cortisol, DHEAS, 24-hour urinary free cortisol and dexamethasone suppression testing, and classified by current European guideline criteria as non-functioning incidentaloma (n=82) or autonomous cortisol secretion (n=83).

Summary: Ueland 2020: in 165 incidentaloma patients, no companion test discriminated autonomous cortisol secretion well, and the 2-day suppression test added nothing over the 1 mg overnight test

Result: Late-night salivary cortisol discriminated poorly between non-functioning incidentalomas and ACS, with 23 of 63 false-positive and 38 of 69 false-negative results. The conventional low-dose (2-day) dexamethasone suppression test did not improve diagnostic specificity compared with the 1 mg overnight DST. DHEAS performed modestly (area under the ROC curve 0.76; sensitivity 58% and specificity 80% at the 1.04 µmol/L (40 µg/dL) cutoff). The authors conclude that none of the companion tests usefully separates non-functioning incidentalomas from ACS and that alternative biomarkers are needed.

Watch out: The reference classification (ACS versus non-functioning) was itself built from the same family of cortisol tests, so this study measures agreement and discrimination within the guideline framework — it cannot supply an independent sensitivity/specificity for the DST against a separate gold standard, because none exists.

Source: Ueland GÅ et al. Diagnostic testing of autonomous cortisol secretion in adrenal incidentalomas. Endocrine connections. 2020. PMID: 33032259. Registry ID: none in the record. MeSH: not captured from the record

Card 2 — Ueland 2017: at the 50 nmol/L cutoff the overnight DST over-called autonomous cortisol secretion — measuring the dexamethasone level removed about 20% of false positives

Study: Prospective diagnostic-accuracy study (Ueland 2017)

Population: 302 subjects who underwent an overnight dexamethasone suppression test with simultaneous serum cortisol, cortisone and dexamethasone measured by LC-MS/MS: 49 patients with suspected Cushing's syndrome, 152 with adrenal incidentaloma and 101 healthy controls, with a replication cohort of 58.

Summary: Ueland 2017: at the 50 nmol/L cutoff the overnight DST over-called autonomous cortisol secretion — measuring the dexamethasone level removed about 20% of false positives

Result: Serum cortisol was at or above 50 nmol/L (about 1.8 µg/dL) after dexamethasone in 83 subjects, of whom 11 had Cushing's syndrome and 27 had autonomous cortisol secretion. Nine patients combined a low serum dexamethasone with a positive DST, and three of them had been misdiagnosed as having ACS — their 'non-suppression' reflected inadequate dexamethasone exposure, not cortisol autonomy. Simultaneous dexamethasone measurement reduced false-positive DSTs by 20% and improved specificity; a serum dexamethasone above 3.3 nmol/L was sufficient for cortisol suppression below 50 nmol/L. DST results were highly reproducible and confirmed in the replication cohort.

Watch out: Part of the DST's apparent inaccuracy is pharmacokinetic — variable dexamethasone absorption and metabolism — not biology; laboratories that do not measure the dexamethasone level cannot make this correction, so real-world specificity is worse than in this LC-MS/MS study.

Source: Ueland GÅ et al. Simultaneous assay of cortisol and dexamethasone improved diagnostic accuracy of the dexamethasone suppression test. European journal of endocrinology. 2017. PMID: 28298353. Registry ID: none in the record. MeSH: Adenoma · Adolescent · Adrenal Gland Neoplasms · Adult · Aged · Aged, 80 and over · Case-Control Studies · Chromatography, Liquid · Cortisone · Cushing Syndrome · Dexamethasone · Female · Humans · Hydrocortisone · Incidental Findings · Male · Middle Aged · Prospective Studies · Saliva · Tandem Mass Spectrometry · Young Adult

Card 3 — Puvaneswaralingam 2021: a post-test ACTH verifies true non-suppression — sensitivity 75–81% and specificity 78–85% for detecting inadequate suppression behind a positive DST

Study: Cross-sectional diagnostic-accuracy study (Puvaneswaralingam 2021)

Population: 373 patients with adrenal incidentalomas and basal ACTH of at least 2.0 pmol/L who underwent a 1 mg overnight DST in a cross-sectional study; post-DST cortisol of at least 50 nmol/L (about 1.8 µg/dL) was found in 140 patients, and post-DST ACTH measures were tested against adequate versus inadequate suppression (the latter defined by the fall in cortisol on a 2-day suppression test, n=16).

Summary: Puvaneswaralingam 2021: a post-test ACTH verifies true non-suppression — sensitivity 75–81% and specificity 78–85% for detecting inadequate suppression behind a positive DST

Result: The best cutoffs for flagging a genuinely non-suppressed result were post-DST ACTH of at least 0.6 pmol/L (sensitivity 75%, specificity 78% for inadequate suppression) and an ACTH ratio of at least 18% of basal (sensitivity 81%, specificity 85%). The authors propose that a post-DST cortisol of at least 50 nmol/L together with a suppressed ACTH (below 0.6 pmol/L, or ACTH ratio below 18%) should raise suspicion of true autonomous cortisol secretion — i.e., the cortisol number alone over-diagnoses, and the ACTH pattern separates assay/absorption artefact from autonomy.

Watch out: The 'inadequate suppression' reference group numbered only 16 patients, so the sensitivity and specificity estimates carry wide uncertainty; this is a verification strategy for positive results, not a replacement screening test.

Source: Puvaneswaralingam S et al. ACTH following overnight dexamethasone suppression can be used in the verification of autonomous cortisol secretion in patients with adrenal incidentalomas. Clinical endocrinology. 2021. PMID: 33108675. Registry ID: none in the record. MeSH: Adrenal Gland Neoplasms · Adrenocorticotropic Hormone · Cross-Sectional Studies · Dexamethasone · Humans · Hydrocortisone · Hypothalamo-Hypophyseal System · Pituitary-Adrenal System

Card 4 — Synthesis: the 1 mg overnight DST is a sensitive screen with threshold-dependent, often poor specificity — a positive result is the start of verification, not a diagnosis

Study: Synthesis

Population: The carded evidence: three diagnostic-accuracy studies in incidentaloma populations (165, 302 and 373 patients). Total carded participants exceed 800, so no small-N stamp labelling applies.

Summary: Synthesis: the 1 mg overnight DST is a sensitive screen with threshold-dependent, often poor specificity — a positive result is the start of verification, not a diagnosis

Result: At the standard cutoff (post-DST cortisol 50 nmol/L, about 1.8 µg/dL), longer suppression protocols added nothing (Ueland 2020), about a fifth of false positives were explained by low dexamethasone exposure and removable by measuring the drug level (Ueland 2017), and a non-suppressed ACTH pattern verified true autonomy with sensitivity 75–81% and specificity 78–85% (Puvaneswaralingam 2021). Because ACS is defined through these same tests, no study can quote a gold-standard sensitivity/specificity — accuracy must be presented as threshold- and assay-dependent, as this shelf does. POSSIBLE (test-accuracy, observational evidence).

Watch out: Quoting any single sensitivity/specificity pair for this test without its cutoff, assay and verification step would misstate the evidence — the ESE/ENSAT categories (possible versus definite ACS by cortisol band) exist precisely because one number cannot carry the diagnosis.

Source: Synthesis of Ueland GÅ et al. Endocrine connections. 2020 (PMID: 33032259); Ueland GÅ et al. European journal of endocrinology. 2017 (PMID: 28298353); Puvaneswaralingam S et al. Clinical endocrinology. 2021 (PMID: 33108675).