Aldosterone-to-renin ratio accuracy: no single number — sensitivity 10–100% across verified studies, respectable only at locally derived, assay-specific cutoffs
Shelf #6062 · Kidney, fluids & electrolytes
POSSIBLE (test-accuracy, observational evidence) — the aldosterone-to-renin ratio is a usable screen whose accuracy is assay- and threshold-dependent (sensitivity 10–100% across rigorously verified studies; about 77–87% sensitivity and 85–93% specificity at locally derived cutoffs), so positives need confirmatory testing and negatives can miss disease
Stamped: 2026-11-28.
Evidence published: 2019–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults being screened for primary aldosteronism, how accurate is the aldosterone-to-renin ratio compared with confirmatory testing?
Balance of the evidence
Test-accuracy shelf, built around the slate's warning: the aldosterone-to-renin ratio (ARR) has no single accuracy. In the most rigorous meta-analysis — restricted to studies that applied confirmatory testing to everyone, whatever the ARR result, to limit verification bias — reported sensitivity ranged from 10% to 100% and specificity from 70% to 100% across ten studies (4,110 participants), three studies found sensitivity below 50%, and the authors could recommend no single threshold (Hung 2021). Performance is assay-dependent in direct comparisons too: in one 450-patient cohort the locally optimal cutoffs gave sensitivity 77% and specificity 93% for the activity-based ratio and sensitivity 80% and specificity 92% for the direct-renin ratio, with different numeric cutoffs for each assay method (Li 2019); pooling the direct-renin variant gave sensitivity 0.87 and specificity 0.85 (Gao 2022). The ratio is therefore a reasonable case-detection screen whose negative result can miss disease at some cutoffs and whose positive result always requires the confirmatory testing it is compared against here. POSSIBLE (test-accuracy, observational evidence), accuracy labelled assay- and threshold-dependent on the face.
MeSH: Aldosterone · Clinical Decision-Making · Female · Humans · Hyperaldosteronism · Male · Renin · Sensitivity and Specificity
Cards (4)
Card 1 — Hung 2021 meta-analysis: ARR sensitivity ranged from 10% to 100% across studies — no single threshold could be recommended
Study: Meta-analysis of 10 diagnostic-accuracy studies (Hung 2021)
Population: Ten observational diagnostic-accuracy studies comprising 4,110 participants screened for primary aldosteronism with the aldosterone-to-renin ratio, selected specifically because every participant underwent dynamic confirmatory testing as the reference standard regardless of the ARR result (limiting verification bias); risk of bias and applicability were assessed with QUADAS-2.
Summary: Hung 2021 meta-analysis: ARR sensitivity ranged from 10% to 100% across studies — no single threshold could be recommended
Result: Reported ARR sensitivity ranged from 10% to 100% and specificity from 70% to 100% across the ten studies; three of the ten studies reported sensitivity below 50%, meaning the screen missed more than half of confirmed cases at the threshold used. The population base, positivity threshold, laboratory assay and confirmatory reference standard varied substantially between studies, and potential risk of bias in patient selection was present in half of them. The authors conclude that no single ARR threshold for interpretation could be recommended and that the test's limited accuracy and reliability must be recognised in clinical decision-making.
Watch out: The spread is the finding: it reflects real differences in assays, thresholds, medications at testing and who was screened — a pooled single sensitivity/specificity would be a false precision, and this review deliberately does not offer one.
Source: Hung A et al. Performance of the Aldosterone to Renin Ratio as a Screening Test for Primary Aldosteronism. The Journal of clinical endocrinology and metabolism. 2021. PMID: 34008000. Registry ID: none in the record. MeSH: Aldosterone · Clinical Decision-Making · Female · Humans · Hyperaldosteronism · Male · Renin · Sensitivity and Specificity
Card 2 — Li 2019: in 450 hypertensive patients, locally optimal cutoffs gave the ARR a sensitivity of 77% and specificity of 93% — with different numbers for each renin assay
Study: Diagnostic-accuracy cohort study (Li 2019)
Population: 450 hypertensive patients with suspected primary aldosteronism at a single hypertension centre who underwent both screening and confirmatory testing; 64 were diagnosed with primary aldosteronism and 386 with primary hypertension. Plasma renin activity and direct renin concentration, and aldosterone by radioimmunoassay and chemiluminescent immunoassay, were measured simultaneously.
Summary: Li 2019: in 450 hypertensive patients, locally optimal cutoffs gave the ARR a sensitivity of 77% and specificity of 93% — with different numbers for each renin assay
Result: The optimal cutoff for the aldosterone-to-direct-renin ratio (chemiluminescent assay) was 2.93 (ng/dL)/(mU/L), with sensitivity 80.33% and specificity 92.11%. The optimal cutoff for the classic aldosterone-to-renin-activity ratio was 25.28 (ng/dL)/(ng/mL/h), with sensitivity 76.92% and specificity 93.38%. Within-patient correlation between the two renin measures was high (r=0.88), but each assay pairing needed its own numeric cutoff — the accuracy figures travel with the assay and the locally derived threshold, not with the test's name.
Watch out: Cutoffs derived and tested in the same single-centre cohort are optimistic ('optimal cutoff' bias), and the 64 confirmed cases limit precision; other centres using other assays cannot import these numbers directly.
Source: Li T et al. Feasibility of Screening Primary Aldosteronism by Aldosterone-to-Direct Renin Concentration Ratio Derived from Chemiluminescent Immunoassay Measurement: Diagnostic Accuracy and Cutoff Value. International journal of hypertension. 2019. PMID: 31354984. Registry ID: none in the record. MeSH: not captured from the record
Card 3 — Gao 2022 meta-analysis: the direct-renin version of the ratio pooled at sensitivity 0.87 and specificity 0.85 (2,806 subjects) — better behaved, still assay-bound
Study: Meta-analysis of 10 diagnostic-accuracy studies (Gao 2022)
Population: Ten studies comprising 2,806 subjects evaluating the aldosterone-to-direct-renin concentration ratio (ADRR) as a screening test for primary aldosteronism, pooled in a systematic review and meta-analysis with QUADAS-2 quality assessment.
Summary: Gao 2022 meta-analysis: the direct-renin version of the ratio pooled at sensitivity 0.87 and specificity 0.85 (2,806 subjects) — better behaved, still assay-bound
Result: Pooled sensitivity was 0.87 (95% CI 0.85 to 0.89) and pooled specificity 0.85 (95% CI 0.83 to 0.86), with an area under the summary ROC curve of 0.9333, a pooled positive likelihood ratio of 5.84 and a negative likelihood ratio of 0.16. The authors conclude the direct-renin ratio has good sensitivity and specificity for screening — while noting that the diagnostic efficacy reported by individual studies varied greatly, which is why pooling was attempted.
Watch out: This pools the direct-renin variant only, largely in different (and partly Chinese-database) study sets from the Hung review; its tidier pooled numbers do not repeal the assay-dependence shown on the other cards — they describe one assay family under study conditions.
Source: Gao H et al. Aldosterone/direct renin concentration ratio as a screening test for primary aldosteronism: a systematic review and meta-analysis. Annals of translational medicine. 2022. PMID: 35845504. Registry ID: none in the record. MeSH: not captured from the record
Card 4 — Synthesis: the ARR screens usefully but its accuracy is a property of the assay, the cutoff and the clinic — not a fixed number
Study: Synthesis
Population: The carded evidence: two diagnostic-accuracy meta-analyses (10 studies / 4,110 participants; 10 studies / 2,806 subjects) and one head-to-head assay cohort (450 patients). Total carded participants exceed 7,000, so no small-N stamp labelling applies.
Summary: Synthesis: the ARR screens usefully but its accuracy is a property of the assay, the cutoff and the clinic — not a fixed number
Result: Against universal confirmatory testing, ARR sensitivity ranged from 10% to 100% and specificity from 70% to 100%, with no recommendable universal threshold (Hung 2021). Where cutoffs are derived locally, performance looks respectable (sensitivity 77–80%, specificity 92–93% in Li 2019; pooled 0.87/0.85 for the direct-renin variant in Gao 2022) — but those numbers belong to their assays and populations. POSSIBLE (test-accuracy, observational evidence): a positive ARR requires confirmatory testing, and a negative ARR at a high cutoff does not exclude primary aldosteronism.
Watch out: Medication effects (mineralocorticoid antagonists, beta-blockers, ACE inhibitors), posture, time of day and potassium all move the ratio; none of the carded accuracy figures survives careless sampling conditions, which is part of why confirmatory testing remains mandatory.
Source: Synthesis of Hung A et al. The Journal of clinical endocrinology and metabolism. 2021 (PMID: 34008000); Li T et al. International journal of hypertension. 2019 (PMID: 31354984); Gao H et al. Annals of translational medicine. 2022 (PMID: 35845504).