SourceMed · Shelf #6073 in the ask interface

Neutral-pH, low-GDP PD solutions — peritonitis and technique failure: balANZ's benefit (homed on #1738) unreproduced across the trial programme and registry practice

Shelf #6073 · Kidney, fluids & electrolytes

SPLIT (single trial vs programme) — balANZ (homed on live #1738) found fewer peritonitis episodes with neutral-pH, low-GDP solution, but the pooled trial programme (Cochrane, 29 trials) found peritonitis differences uncertain and technique failure or death little or no different, a small randomised trial found no peritonitis difference, and a national registry analysis found a higher peritonitis rate on biocompatible solutions (incidence rate ratio 1.49, relative)

Stamped: 2026-11-28.

Evidence published: 2007–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults on peritoneal dialysis, do neutral-pH, low-glucose-degradation-product solutions reduce peritonitis and technique failure compared with conventional solutions?

Balance of the evidence

SPLIT (single trial vs programme) — a completion of live shelf #1738, built under the documented precedent for a homed anchor with a genuinely different slice: #1738 asks whether these solutions preserve residual kidney function (answer: no, on balANZ's primary outcome) and cards balANZ's two reports (PMIDs 22440906 and 22991015, both on the gate list and NOT re-carded here). This shelf asks the programme-wide peritonitis and technique-failure question, which #1738 touches only through balANZ's secondary peritonitis analysis. On the free reports, the answer splits: the Cochrane review of 29 neutral-pH low-GDP trials (1,971 participants) found peritonitis differences uncertain and technique failure or death little or no different (the treatment made no difference); a 50-patient randomised trial found no peritonitis difference; and the ANZDATA registry analysis found biocompatible-solution patients with a higher peritonitis rate (0.67 vs 0.47 episodes per patient-year; incidence rate ratio 1.49 relative). So balANZ's peritonitis advantage (0.30 vs 0.49 episodes per patient-year, on #1738) stands unreproduced across the wider programme, and no technique-failure benefit is shown anywhere carded. SPLIT (single trial vs programme): peritonitis reduction in one trial's secondary analysis; no confirmed peritonitis or technique-survival benefit programme-wide.

MeSH: Adult · Bicarbonates · Child · Dialysis Solutions · Glucose · Humans · Hydrogen-Ion Concentration · Icodextrin · Kidney · Peritoneal Dialysis · Peritoneum · Pharmaceutical Solutions · Randomized Controlled Trials as Topic · Urine

Cards (4)

Card 1 — Cochrane 2018: across 29 randomised trials (1,971 participants) of neutral-pH, low-GDP solutions, peritonitis differences were uncertain and technique failure or death may make little or no difference (low certainty)

Study: Systematic review of randomised trials (Cochrane, Htay 2018)

Population: Adults and children on peritoneal dialysis in the 42 randomised and quasi-randomised trials (3,262 participants) of biocompatible solutions in the 2018 Cochrane update, of which 29 studies (1,971 participants) compared a neutral-pH, low-glucose-degradation-product solution with a conventional solution — the comparison this shelf asks about; icodextrin trials in the review are a different intervention and are not used here.

Summary: Cochrane 2018: across 29 randomised trials (1,971 participants) of neutral-pH, low-GDP solutions, peritonitis differences were uncertain and technique failure or death may make little or no difference (low certainty)

Result: For neutral-pH, low-GDP versus conventional solutions, the review found it uncertain whether there were any differences in peritonitis occurrence, hospitalisation or adverse events, and that the solutions may make little or no difference to technique failure or death (low certainty evidence) — the treatment made no difference on the technique outcome. (The same review's residual-kidney-function findings belong to live shelf #1738's question and are not re-carded here.)

Watch out: The review pools the balANZ trial — whose own peritonitis result, homed on live shelf #1738, favoured the biocompatible solution — with many smaller, shorter trials; a pooled 'uncertain' can hide one large positive trial, which is precisely the split this shelf exists to display.

Source: Htay H et al. Biocompatible dialysis fluids for peritoneal dialysis. The Cochrane database of systematic reviews. 2018. PMID: 30362116. Registry ID: none in the record for the review itself. MeSH: Adult · Bicarbonates · Child · Dialysis Solutions · Glucose · Humans · Hydrogen-Ion Concentration · Icodextrin · Kidney · Peritoneal Dialysis · Peritoneum · Pharmaceutical Solutions · Randomized Controlled Trials as Topic · Urine

Card 2 — Cho 2013 (ANZDATA registry): incident Australian PD patients on biocompatible solutions had a higher peritonitis rate than patients on conventional solutions — 0.67 vs 0.47 episodes per patient-year, incidence rate ratio 1.49

Study: Registry cohort study (ANZDATA, Cho 2013)

Population: All incident Australian patients receiving peritoneal dialysis between 1 January 2007 and 31 December 2010 in the Australia and New Zealand Dialysis and Transplant Registry, classified by whether their solution was a multicompartment neutral-pH (biocompatible) product; the total number of patients is not documented in the record (N not documented). Biocompatible use was uncommon and falling (7.5% of patients in 2007 to 4.2% in 2010) and was preferentially used by smaller units and in younger patients without diabetes.

Summary: Cho 2013 (ANZDATA registry): incident Australian PD patients on biocompatible solutions had a higher peritonitis rate than patients on conventional solutions — 0.67 vs 0.47 episodes per patient-year, incidence rate ratio 1.49

Result: Treatment with a biocompatible solution was associated with a significantly greater overall peritonitis rate (0.67 versus 0.47 episodes per patient-year; incidence rate ratio 1.49, 95% CI 1.19 to 1.89) and a shorter time to first peritonitis (hazard ratio 1.48, 95% CI 1.17 to 1.87), a finding replicated in propensity-score-matched cohorts (hazard ratio 1.36, 95% CI 1.09 to 1.71). The authors call for randomised studies adequately powered for peritonitis as a primary outcome.

Watch out: Observational and opposite in direction to the balANZ trial result homed on #1738: with only 4–8% of patients on biocompatible solutions, chosen by particular units for particular patients, confounding by unit practice and case mix is a live explanation — but so is a real absence of the protection balANZ suggested.

Source: Cho Y et al. Association of biocompatible peritoneal dialysis solutions with peritonitis risk, treatment, and outcomes. Clinical journal of the American Society of Nephrology : CJASN. 2013. PMID: 23949232. Registry ID: none in the record. MeSH: Adult · Aged · Australia · Biocompatible Materials · Dialysis Solutions · Disease-Free Survival · Female · Humans · Incidence · Male · Middle Aged · Peritoneal Dialysis · Peritonitis · Time Factors · Treatment Outcome

Card 3 — Szeto 2007: in 50 new PD patients randomised to a neutral-pH, low-GDP solution or conventional solution for 12 months, peritonitis rate and hospitalisation did not differ (the treatment made no difference) — while membrane biomarkers favoured the new solution

Study: Randomised controlled trial (Szeto 2007)

Population: 50 new peritoneal dialysis patients randomised to a conventional lactate-buffered fluid or a pH-neutral, lactate-buffered, low-GDP solution (the tested product is named in the publication as 'balance') and followed for 12 months, with effluent cancer antigen-125 and hyaluronan, serum C-reactive protein, adequacy, ultrafiltration and clinical endpoints including peritonitis and hospitalisation.

Summary: Szeto 2007: in 50 new PD patients randomised to a neutral-pH, low-GDP solution or conventional solution for 12 months, peritonitis rate and hospitalisation did not differ (the treatment made no difference) — while membrane biomarkers favoured the new solution

Result: There was no difference between groups in dialysis adequacy, ultrafiltration volume, urine output, residual renal function, peritonitis rate or need for hospitalisation over 1 year (the treatment made no difference on the clinical outcomes). The biocompatibility markers did move: effluent CA-125 was higher on the neutral solution at 52 weeks (14.30±2.17 vs 7.36±2.23 U/mL, P=0.007), hyaluronan lower (1.45±0.32 vs 2.55±0.32 µg/mL, P=0.007), and serum CRP lower (1.77±0.42 vs 7.73±2.42 mg/L, P=0.026).

Watch out: Fifty patients for 12 months cannot detect a peritonitis difference of the size balANZ reported, and this trial's own authors frame it as a biocompatibility-marker study: better-looking effluent markers, no clinical difference shown.

Source: Szeto CC et al. Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products--a 1-year randomized control trial. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2007. PMID: 17005526. Registry ID: none in the record. MeSH: Biomarkers · CA-125 Antigen · Dialysis Solutions · Endothelium · Female · Follow-Up Studies · Glucose · Humans · Hyaluronic Acid · Kidney Failure, Chronic · Male · Middle Aged · Patient Satisfaction · Peritoneal Dialysis · Peritoneum · Prospective Studies · Quality of Life · Time Factors · Treatment Outcome

Card 4 — Synthesis: programme-wide, neutral-pH low-GDP solutions have not been shown to reduce peritonitis or technique failure — the pooled trials are null/uncertain, a small trial is null, and the largest registry analysis points the other way; the positive peritonitis result is one trial's secondary outcome, homed on #1738

Study: Synthesis

Population: The carded evidence: a Cochrane review of 29 neutral-pH low-GDP randomised trials (1,971 participants), a national registry cohort of incident Australian PD patients 2007–2010 (total N not documented in the record), and a 50-patient randomised trial. The balANZ trial's own reports (PMIDs 22440906 and 22991015) are homed on live shelf #1738 and are deliberately not re-carded here, in line with the one-home rule; this shelf was built on the free programme-wide reports under that precedent.

Summary: Synthesis: programme-wide, neutral-pH low-GDP solutions have not been shown to reduce peritonitis or technique failure — the pooled trials are null/uncertain, a small trial is null, and the largest registry analysis points the other way; the positive peritonitis result is one trial's secondary outcome, homed on #1738

Result: balANZ remains the only large trial with a positive peritonitis result (0.30 vs 0.49 episodes per patient-year, on live shelf #1738, where it is a secondary outcome of a trial whose primary kidney-function outcome was null). Everything carded here qualifies or contradicts it: the Cochrane pooling of the whole neutral-pH low-GDP trial programme found peritonitis differences uncertain and technique failure or death little or no different; the small dedicated trial found no peritonitis difference; and the ANZDATA registry analysis found biocompatible-solution patients with a higher peritonitis rate (incidence rate ratio 1.49 relative) and shorter time to first peritonitis. On technique failure specifically, no carded report shows a benefit. SPLIT (single trial vs programme): a peritonitis reduction seen in one trial's secondary analysis has not been reproduced across the trial programme or in registry practice, and no technique-survival benefit has been shown.

Watch out: The Cochrane pool includes balANZ itself, so the cards are not fully independent of the homed trial; and the registry result is observational. The honest summary is not 'the solutions cause peritonitis' but 'the protection claimed from one trial is unconfirmed everywhere else'.

Source: Synthesis of Htay H et al. Cochrane database of systematic reviews. 2018 (PMID: 30362116); Cho Y et al. Clinical journal of the American Society of Nephrology : CJASN. 2013 (PMID: 23949232); Szeto CC et al. Nephrology, dialysis, transplantation. 2007 (PMID: 17005526).