SourceMed · Shelf #6168 in the ask interface

Plasma p-tau217 for Alzheimer's pathology in people with cognitive symptoms: about 90% accuracy at predefined cutoffs — with each figure tied to its named assay and setting

Shelf #6168 · Brain, stroke & mind

POSSIBLE (test-accuracy, cohort evidence) — plasma p-tau217 identified Alzheimer's pathology with AUC 0.89–0.97 across cohorts and about 90% diagnostic accuracy at predefined cutoffs in primary and secondary care; performance is assay- and setting-dependent

Stamped: 2026-11-28.

Evidence published: 2020–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does a plasma phosphorylated-tau (p-tau217) blood test identify Alzheimer's disease pathology in people presenting with cognitive symptoms?

Balance of the evidence

In people with cognitive symptoms, plasma p-tau217 identified Alzheimer's disease pathology with high accuracy in every carded cohort — but the numbers are assay- and setting-dependent, and each card names the assay or method its figures belong to. Palmqvist 2020 (1,402 participants across an Arizona neuropathology cohort, BioFINDER-2, and a Colombian autosomal-dominant kindred) found an area under the curve of 0.96 for clinical Alzheimer's dementia versus other neurodegenerative diseases and 0.93 for abnormal tau-PET. Palmqvist 2024 tested a mass-spectrometry method (percentage p-tau217, alone and combined with the amyloid-beta 42/40 ratio as the APS2 score) prospectively in 1,213 Swedish patients with cognitive symptoms: diagnostic accuracy was 88–92% in primary and secondary care at predefined cutoffs, against 61% for primary care physicians and 73% for dementia specialists using clinical workup alone. Ashton 2024 validated the commercially available ALZpath pTau217 immunoassay in 786 participants (TRIAD, WRAP and SPIN cohorts): AUC 0.92–0.96 for amyloid pathology and 0.93–0.97 for tau pathology. POSSIBLE (test-accuracy, cohort evidence): accuracy around 90% at predefined cutoffs in symptomatic populations is consistently reported, but cutoffs and performance do not transfer automatically between assays, platforms or care settings.

MeSH: Adult · Aged · Aged, 80 and over · Alzheimer Disease/blood/diagnosis · Amyloid beta-Peptides · Area Under Curve · Biomarkers/blood · Cross-Sectional Studies · Female · Humans · Magnetic Resonance Imaging · Male · Middle Aged · Mutation · Neurodegenerative Diseases/blood/diagnosis · Plaque, Amyloid/blood · Positron-Emission Tomography · Presenilin-1/genetics · tau Proteins/blood

Cards (4)

Card 1 — Palmqvist 2020 (JAMA): plasma P-tau217 separated Alzheimer's dementia from other neurodegenerative diseases with AUC 0.96, and abnormal from normal tau-PET with AUC 0.93, across 1,402 participants in 3 cohorts

Study: Diagnostic-accuracy cohort study, 3 cohorts (Palmqvist 2020)

Population: 1,402 participants in three cross-sectional cohorts: an Arizona neuropathology cohort (34 with Alzheimer's disease and 47 without), the Swedish BioFINDER-2 cohort (301 cognitively unimpaired, 178 with mild cognitive impairment, 121 with Alzheimer's dementia, 99 with other neurodegenerative diseases), and a Colombian autosomal-dominant Alzheimer's kindred (365 PSEN1 E280A carriers and 257 noncarriers). The reference standards were neuropathology, clinical diagnosis, and tau- and amyloid-PET.

Summary: Palmqvist 2020 (JAMA): plasma P-tau217 separated Alzheimer's dementia from other neurodegenerative diseases with AUC 0.96, and abnormal from normal tau-PET with AUC 0.93, across 1,402 participants in 3 cohorts

Result: Antemortem plasma P-tau217 differentiated neuropathologically defined Alzheimer's disease from non-Alzheimer's disease with AUC 0.89 (95% CI 0.81 to 0.97), significantly more accurately than plasma P-tau181 or neurofilament light (AUC range 0.50–0.72). In BioFINDER-2, accuracy for clinical Alzheimer's dementia versus other neurodegenerative diseases was AUC 0.96 (95% CI 0.93 to 0.98), not significantly different from cerebrospinal fluid P-tau217, P-tau181 or tau-PET (AUC range 0.90–0.99); for discriminating abnormal from normal tau-PET scans the AUC was 0.93 (95% CI 0.91 to 0.96). In the Colombian kindred, plasma P-tau217 was already significantly higher in mutation carriers from about age 25, some 20 years before estimated mild cognitive impairment onset.

Watch out: These were selected research cohorts — including a neuropathology series and a young autosomal-dominant kindred (mean age 35.8 years) — not unselected clinic attenders; the record does not name a commercial assay platform, and the authors state the assay still needed optimisation and validation in unselected, diverse populations.

Source: Palmqvist S et al. Discriminative Accuracy of Plasma Phospho-tau217 for Alzheimer Disease vs Other Neurodegenerative Disorders. JAMA. 2020. PMID: 32722745. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Alzheimer Disease/blood/diagnosis · Amyloid beta-Peptides · Area Under Curve · Biomarkers/blood · Cross-Sectional Studies · Female · Humans · Magnetic Resonance Imaging · Male · Middle Aged · Mutation · Neurodegenerative Diseases/blood/diagnosis · Plaque, Amyloid/blood · Positron-Emission Tomography · Presenilin-1/genetics · tau Proteins/blood

Card 2 — Palmqvist 2024 (JAMA): a mass-spectrometry percentage p-tau217 test (APS2) reached 88–92% diagnostic accuracy in 1,213 patients with cognitive symptoms in primary and secondary care — versus 61% and 73% for clinicians' own workup

Study: Prospective diagnostic-accuracy cohort study, primary and secondary care (Palmqvist 2024)

Population: 1,213 patients undergoing clinical evaluation for cognitive symptoms in Sweden (23% subjective cognitive decline, 44% mild cognitive impairment, 33% dementia; 50% had Alzheimer's pathology), assessed in primary care and secondary care cohorts, in single-batch analyses and in a prospective biweekly analysis, using predefined biomarker cutoff values established in an independent cohort. The test used mass spectrometry to measure the ratio of plasma phosphorylated tau 217 to non-phosphorylated tau 217 (percentage p-tau217), alone and combined with the plasma amyloid-beta 42/40 ratio as the amyloid probability score 2 (APS2); the reference standard was abnormal cerebrospinal fluid amyloid-beta 42/40 and p-tau217.

Summary: Palmqvist 2024 (JAMA): a mass-spectrometry percentage p-tau217 test (APS2) reached 88–92% diagnostic accuracy in 1,213 patients with cognitive symptoms in primary and secondary care — versus 61% and 73% for clinicians' own workup

Result: With APS2, AUC was 0.96–0.97 in both settings and both analysis modes; positive predictive values were 88–91% and negative predictive values 87–92%, and diagnostic accuracy ranged from 88% to 92% across the four cohorts. Overall diagnostic accuracy with APS2 was 90% (95% CI 88% to 92%), not different from percentage p-tau217 alone (90%, 95% CI 88% to 91%). Primary care physicians identified clinical Alzheimer's disease with 61% accuracy (95% CI 53% to 69%) after examination, cognitive testing and CT, versus 91% using APS2; dementia specialists achieved 73% (95% CI 68% to 79%) versus 91% with APS2.

Watch out: Predictive values were measured where half the patients had Alzheimer's pathology; in a lower-prevalence setting the same test would yield more false positives. The figures belong to this mass-spectrometry percentage p-tau217 method and its predefined cutoffs — they are not a property of every p-tau217 assay.

Source: Palmqvist S et al. Blood Biomarkers to Detect Alzheimer Disease in Primary Care and Secondary Care. JAMA. 2024. PMID: 39068545. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Female · Humans · Male · Middle Aged · Alzheimer Disease/diagnosis/blood · Amyloid beta-Peptides/blood · Biomarkers/blood · Cognitive Dysfunction/diagnosis/blood · Peptide Fragments/blood · Phosphorylation · Primary Health Care · Prospective Studies · Secondary Health Care · Sensitivity and Specificity · Sweden · tau Proteins/blood

Card 3 — Ashton 2024: the commercially available ALZpath pTau217 immunoassay identified amyloid pathology with AUC 0.92–0.96 and tau pathology with AUC 0.93–0.97 across 786 participants in 3 cohorts

Study: Diagnostic-accuracy cohort study, 3 cohorts (Ashton 2024, ALZpath assay)

Population: 786 participants (mean age 66.3 years; 64.1% women) with and without cognitive impairment from three single-centre observational cohorts — TRIAD (Canada), the Wisconsin Registry for Alzheimer's Prevention (WRAP), and SPIN (Spain) — grouped by amyloid and tau status using PET or cerebrospinal fluid biomarkers. The tested product is named as published: the ALZpath pTau217 assay, a commercially available plasma p-tau217 immunoassay.

Summary: Ashton 2024: the commercially available ALZpath pTau217 immunoassay identified amyloid pathology with AUC 0.92–0.96 and tau pathology with AUC 0.93–0.97 across 786 participants in 3 cohorts

Result: Plasma p-tau217 on the ALZpath assay showed high accuracy for elevated amyloid-beta (AUC 0.92–0.96, 95% CI 0.89–0.99) and for tau pathology (AUC 0.93–0.97, 95% CI 0.84–0.99) across all cohorts, comparable with cerebrospinal fluid biomarkers for determining abnormal PET signal. A 3-range reference for abnormal amyloid pathology gave reproducible results and reduced confirmatory testing by approximately 80%. Longitudinally, plasma p-tau217 rose annually only in amyloid-positive individuals, most in those also tau-positive.

Watch out: WRAP is a prevention registry enriched for Alzheimer's risk and many participants were cognitively unimpaired, so these AUCs describe detecting pathology across a wide spectrum — accuracy for the narrower question 'does this symptomatic patient's presentation reflect Alzheimer's pathology' comes mainly from the Palmqvist 2024 card. AUC ranges span cohorts; no single cutoff performed identically everywhere.

Source: Ashton NJ et al. Diagnostic Accuracy of a Plasma Phosphorylated Tau 217 Immunoassay for Alzheimer Disease Pathology. JAMA neurology. 2024. PMID: 38252443. Registry ID: none in the record. MeSH: Aged · Female · Humans · Male · Alzheimer Disease/diagnostic imaging · Amyloid · Amyloid beta-Peptides/cerebrospinal fluid · Biomarkers · Cognitive Dysfunction · Cohort Studies · Cross-Sectional Studies · Immunoassay · Positron-Emission Tomography · tau Proteins/cerebrospinal fluid · Observational Studies as Topic

Card 4 — Synthesis: accuracy is consistently high in symptomatic cohorts — around 90% at predefined cutoffs — and is a property of a named assay in a named setting, not of 'p-tau217' in general

Study: Synthesis

Population: The carded evidence: three diagnostic-accuracy reports covering more than 3,300 participants — a 3-cohort discrimination study (1,402), a prospective primary/secondary care study (1,213 patients with cognitive symptoms), and a 3-cohort validation of the ALZpath immunoassay (786).

Summary: Synthesis: accuracy is consistently high in symptomatic cohorts — around 90% at predefined cutoffs — and is a property of a named assay in a named setting, not of 'p-tau217' in general

Result: Reported accuracy clusters tightly despite different methods: AUC 0.96 for Alzheimer's dementia versus other neurodegenerative disease (research assay, BioFINDER-2), 88–92% diagnostic accuracy at predefined cutoffs in primary and secondary care (mass-spectrometry percentage p-tau217/APS2), and AUC 0.92–0.97 for amyloid and tau pathology (ALZpath immunoassay). POSSIBLE (test-accuracy, cohort evidence): plasma p-tau217 identifies Alzheimer's pathology accurately in people with cognitive symptoms, with the caveat that each figure belongs to its assay, cutoff and population.

Watch out: Accuracy is not clinical utility: none of these cards shows that testing changed management or outcomes, and predictive values will fall where Alzheimer's pathology is less prevalent than the 50% seen in the 2024 care cohorts. Do not carry one assay's cutoff or accuracy figure onto another platform.

Source: Synthesis of Palmqvist S et al. JAMA. 2020 (PMID: 32722745); Palmqvist S et al. JAMA. 2024 (PMID: 39068545); Ashton NJ et al. JAMA neurology. 2024 (PMID: 38252443).