Repeat selective laser trabeculoplasty after the first treatment wears off: pressure falls again in cohort studies — observational evidence only, no randomised trial

Shelf #6244 · Eyes, skin, nose & allergy

POSSIBLE (benefit) — observational evidence only (all carded reports are retrospective cohorts; no randomised trial exists), labelled observational

Stamped: 2026-11-28.

Evidence published: 2009–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with open-angle glaucoma whose first selective laser trabeculoplasty worked and then wore off, does repeating the laser lower pressure again?

Balance of the evidence

POSSIBLE (benefit), observational evidence only. Four retrospective cohorts agree that repeating 360-degree selective laser trabeculoplasty (SLT) after a first successful treatment has worn off lowers intraocular pressure again: Hong 2009 (44 eyes) found a smaller reduction than the first treatment at 1–3 months (−2.9 vs −5.0 mm Hg) but no significant difference at other time points or in success rates; Avery 2013 (42 eyes) found no significant difference in reduction or success and significantly longer benefit from the repeat; Khouri 2014 found significant reductions sustained to 24 months (29% of eyes over 20% at 2 years). No randomised trial exists, retreatment was chosen clinically in every cohort, and concurrent drops were not controlled — so the stamp is capped at POSSIBLE and the evidence is labelled observational on every card. Live shelf #609 asks laser-first versus drops (LiGHT) — a different question; repeat treatment is not its question.

MeSH: Aged · Exfoliation Syndrome/physiopathology,surgery · Female · Glaucoma, Open-Angle/physiopathology,surgery · Humans · Intraocular Pressure/physiology · Laser Therapy · Male · Reoperation · Retrospective Studies · Tonometry, Ocular · Trabeculectomy · Treatment Outcome

Cards (5)

Card 1 — Hong 2009: repeat 360-degree SLT lowered pressure again after a first successful treatment wore off — by less than the first treatment at 1–3 months (−2.9 vs −5.0 mm Hg), with no significant difference at the other time points

Study: Primary study (observational cohort)

Population: Retrospective chart review (observational): 44 eyes of 35 patients aged 18 or over with open-angle glaucoma (primary open-angle, pseudoexfoliation or pigmentary), uncontrolled on maximum tolerable medical therapy, whose initial 360-degree selective laser trabeculoplasty (SLT1) was successful for at least 6 months, then lost efficacy and was followed by repeat 360-degree SLT (SLT2). Prior argon laser trabeculoplasty or glaucoma surgery excluded.

Summary: Hong 2009: repeat 360-degree SLT lowered pressure again after a first successful treatment wore off — by less than the first treatment at 1–3 months (−2.9 vs −5.0 mm Hg), with no significant difference at the other time points

Result: Intraocular pressure fell after both treatments. The reduction was significantly smaller after repeat treatment at 1–3 months (average −2.9 mm Hg after SLT2 vs −5.0 mm Hg after SLT1, P=0.01), with no statistically significant difference at 1–4 weeks or 5–8 months. Using success as at least a 20% reduction from peak pressure, success rates for SLT1 and SLT2 were not significantly different, and timing of the repeat (6–12 months vs 12 months or more after SLT1) made no significant difference. The authors conclude repeat 360-degree SLT may be safe and effective after an initially successful treatment has failed, from as early as 6 months.

Watch out: Retrospective and uncontrolled: eyes were selected for retreatment clinically, concurrent drops were not controlled, and regression to the mean cannot be excluded — hence the observational cap on the stamp.

Source: Observational cohort (retrospective chart review) | Hong BK et al. Repeat selective laser trabeculoplasty. J Glaucoma. 2009. PMID: 19295367. Registry ID: none in the record (observational, pre-registration era practice). MeSH: Aged · Exfoliation Syndrome/physiopathology,surgery · Female · Glaucoma, Open-Angle/physiopathology,surgery · Humans · Intraocular Pressure/physiology · Laser Therapy · Male · Reoperation · Retrospective Studies · Tonometry, Ocular · Trabeculectomy · Treatment Outcome

Card 2 — Avery 2013: repeat primary SLT matched the first treatment on pressure reduction, success rate — and lasted significantly longer

Study: Primary study (observational cohort)

Population: Retrospective study (observational): 42 eyes of 42 patients with primary open-angle glaucoma. All had primary SLT (40–50 shots over 360 degrees); SLT was repeated in all patients after failure to maintain target intraocular pressure. Success was a pressure reduction of at least 20% and below an individually determined target.

Summary: Avery 2013: repeat primary SLT matched the first treatment on pressure reduction, success rate — and lasted significantly longer

Result: No significant difference between initial and repeat treatments was found for mean reduction in intraocular pressure, success rate, or (on the primary comparison) duration of success; survival analysis found significantly longer benefit for repeat treatment compared with initial treatment (P<0.01). The authors conclude repeat SLT has similar efficacy to primary SLT for pressure reduction and success rates, with a longer duration of treatment success.

Watch out: A single retrospective series; 'no significant difference' in a 42-eye cohort is not proof of equivalence, and the longer repeat benefit comes from one survival analysis.

Source: Observational cohort (retrospective) | Avery N et al. Repeatability of primary selective laser trabeculoplasty in patients with primary open-angle glaucoma. Int Ophthalmol. 2013. PMID: 23371484. Registry ID: none in the record (observational). MeSH: Aged · Female · Glaucoma, Open-Angle/physiopathology,surgery · Humans · Intraocular Pressure/physiology · Laser Therapy/methods · Male · Middle Aged · Reproducibility of Results · Retrospective Studies · Trabecular Meshwork/surgery · Trabeculectomy/methods

Card 3 — Khouri 2014 (long-term cohort): repeat SLT kept pressure significantly below baseline out to 24 months, with 29% of eyes achieving over 20% reduction at 2 years

Study: Primary study (observational cohort)

Population: Single-centre retrospective review (observational): 45 eyes of 25 subjects (mean age 73 ± 9 years) with open-angle glaucoma undergoing repeat SLT, at a mean interval of 28.3 ± 12.7 months after the initial treatment. Eyes with prior argon laser trabeculoplasty or incisional surgery excluded.

Summary: Khouri 2014 (long-term cohort): repeat SLT kept pressure significantly below baseline out to 24 months, with 29% of eyes achieving over 20% reduction at 2 years

Result: Mean intraocular pressure reductions after repeat SLT were statistically significant versus baseline at 1, 4, 8, 12, 18 and 24 months. Reductions after first and repeat SLT were comparable at most time points except 4, 8 and 12 months, when the initial treatment had yielded significantly greater reductions. At 24 months, 29% of eyes achieved a reduction over 20% and 39% at least 15% after repeat SLT, versus 36% and 54% after initial treatment (P>0.05).

Watch out: Retrospective, single centre, 25 subjects contributing 45 eyes (eyes are not independent); the record for this paper carries no MeSH list — see the fallback note on the source line.

Source: Observational cohort (retrospective) | Khouri AS et al. Long term efficacy of repeat selective laser trabeculoplasty. J Ophthalmic Vis Res. 2014. PMID: 25709769. Registry ID: none in the record (observational). MeSH: not captured from the record

Card 4 — Khouri 2014 (modest-response cohort): eyes that responded only modestly to a first SLT succeeded after repeat SLT about as often as initial strong responders (37% vs 52%, not significant)

Study: Primary study (observational cohort)

Population: Retrospective chart review (observational): 51 eyes receiving initial 360-degree SLT (SLT1) and subsequent SLT (SLT2), 2003–2011, at a large academic ophthalmology practice. Successful response was a 12-month mean pressure reduction of at least 20%; modest response was under 20%.

Summary: Khouri 2014 (modest-response cohort): eyes that responded only modestly to a first SLT succeeded after repeat SLT about as often as initial strong responders (37% vs 52%, not significant)

Result: Pressure fell significantly from baseline after both SLT1 and SLT2. The proportion succeeding after repeat treatment did not differ significantly between eyes whose initial response was modest and those whose initial response was successful (36.67% vs 52.38%, P=0.26), and log-rank analysis found no difference in repeat success by initial response class (P=0.41). The authors raise the possibility that repeat SLT should not be excluded after only a modest initial response. Note this cohort answers a neighbouring question — repeat after a modest first response — rather than repeat after a successful-then-worn-off first treatment.

Watch out: This cohort's first responses were modest, not successful-then-worn-off — it supports repeat SLT generally but is one step removed from this shelf's exact question, and it is retrospective.

Source: Observational cohort (retrospective) | Khouri AS et al. Repeat selective laser trabeculoplasty can be effective in eyes with initial modest response. Middle East Afr J Ophthalmol. 2014. PMID: 25100902. Registry ID: none in the record (observational). MeSH: Glaucoma, Open-Angle/surgery · Humans · Intraocular Pressure · Laser Therapy · Reoperation · Retrospective Studies · Trabeculectomy · Treatment Outcome

Card 5 — Synthesis: repeat SLT lowers pressure again in every carded cohort — but all of the evidence is observational, so the stamp is capped at POSSIBLE

Study: Synthesis

Population: Synthesis of the four carded observational cohorts (Hong 2009; Avery 2013; Khouri 2014 long-term; Khouri 2014 modest-response). No randomised trial of repeat selective laser trabeculoplasty was found in the fetched records.

Summary: Synthesis: repeat SLT lowers pressure again in every carded cohort — but all of the evidence is observational, so the stamp is capped at POSSIBLE

Result: Across cohorts, repeat 360-degree SLT after a first treatment has worn off lowers intraocular pressure again, typically by somewhat less than the first treatment at some time points (Hong: −2.9 vs −5.0 mm Hg at 1–3 months) and by a comparable amount at others, with roughly three in ten eyes still achieving over 20% reduction at 24 months (Khouri long-term) and with repeat benefit lasting at least as long as the first in the one survival analysis (Avery). Because every carded report is a retrospective, uncontrolled cohort, regression to the mean, concurrent medication changes and selection of eyes for retreatment cannot be excluded — the evidence is observational throughout and the stamp is capped accordingly. First-line laser versus drops is a different question, homed on live shelf #609 (the LiGHT trial); this shelf is only about repeating a treatment that worked and then wore off.

Watch out: Synthesis of observational cohorts only; a randomised trial of repeat SLT would be needed to lift the stamp above POSSIBLE.

Source: Synthesis of Hong BK et al. J Glaucoma. 2009 (PMID: 19295367); Avery N et al. Int Ophthalmol. 2013 (PMID: 23371484); Khouri AS et al. J Ophthalmic Vis Res. 2014 (PMID: 25709769); Khouri AS et al. Middle East Afr J Ophthalmol. 2014 (PMID: 25100902). Registry IDs: none in the records (all observational).