SourceMed · Shelf #6245 in the ask interface

How fast PaCO2 rises during apnoea: a fast first minute, then about 3–6 mm Hg per minute depending on state — the Frumin and Stock measurements

Shelf #6245 · Lungs, breathing & sleep

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1959–1989.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, how fast does arterial carbon dioxide rise during apnoea, and what determines the rate?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Framed by Guyton & Hall and Ganong (textbook framing, not evidence). The human measurements are concordant: PaCO2 rise in apnoea is logarithmic — fast at first as arterial blood equilibrates toward mixed venous PCO2 (Stock 1988, awake: 7 mm Hg in the first 10 seconds; Stock 1989, anaesthetised and obstructed: 12 mm Hg in the first minute), then roughly linear at about 6 mm Hg/minute awake (Stock 1988, 20 volunteers) and 3.4 mm Hg/minute anaesthetised (Stock 1989, 14 adults). Frumin 1959 established that apnoeic oxygenation keeps oxygen flowing while CO2 accumulates; Stock 1989 showed the oxygen flow does not meaningfully eliminate CO2, so the steady rate is set by CO2 production and body stores. Classic small studies; Ns are printed on the card faces.

MeSH: Adult · Apnea/blood · Carbon Dioxide/analysis,blood · Consciousness · Functional Residual Capacity/physiology · Humans · Hypercapnia/blood · Lung Volume Measurements · Models, Biological · Tidal Volume/physiology · Time Factors · Total Lung Capacity/physiology

Cards (4)

Card 1 — Frumin 1959: the apnoeic-oxygenation experiments — with oxygen supplied, apnoeic patients stayed oxygenated while carbon dioxide accumulated (the programme anchor; the record carries no abstract)

Study: Primary human physiology study

Population: Humans undergoing apnoeic oxygenation (denitrogenated, oxygen insufflated) in the Frumin, Epstein and Cohen experiments, Anesthesiology 1959. N not documented in the fetched record (the record carries no abstract).

Summary: Frumin 1959: the apnoeic-oxygenation experiments — with oxygen supplied, apnoeic patients stayed oxygenated while carbon dioxide accumulated (the programme anchor; the record carries no abstract)

Result: The fetched record establishes the study and its design (apnoeic oxygenation in man) but prints no abstract and no numbers, so no rate is taken from this card. The quantitative rates on this shelf come from the Stock measurements below. In the textbook account (Guyton & Hall; Ganong), the Frumin experiments are the classic demonstration that oxygenation can be maintained during apnoea by mass movement of oxygen while PaCO2 climbs steadily — the basis for the modern apnoeic-oxygenation technique.

Watch out: The fetched record carries no abstract and no N, so this card contributes the programme anchor only — every number on this shelf comes from the Stock cards, and the Frumin framing is labelled as the textbook's account.

Source: Primary human physiology study (classic, 1959) | Frumin MJ et al. Apneic oxygenation in man. Anesthesiology. 1959. PMID: 13825447. Registry ID: none in the record (classic physiology, pre-registration era). MeSH: Apnea · Humans · Male · Oxygen Inhalation Therapy · Respiration, Artificial

Card 2 — Stock 1988 (awake volunteers): PaCO2 rose fastest at the very start of apnoea — about 7 mm Hg in the first 10 seconds — then settled to about 6 mm Hg per minute

Study: Primary human physiology study

Population: 20 awake volunteers who held their breath at functional residual capacity with FiO2 1.0, for 0, 10 and 20 seconds and then as long as possible, exhaling through an infrared CO2 analyser after each interval to estimate the arterial CO2 rise.

Summary: Stock 1988 (awake volunteers): PaCO2 rose fastest at the very start of apnoea — about 7 mm Hg in the first 10 seconds — then settled to about 6 mm Hg per minute

Result: The estimated PaCO2 rise was logarithmic: 7 mm Hg during the first 10 seconds (43 mm Hg/minute), 2 mm Hg during the next 10 seconds (13 mm Hg/minute), and 6 mm Hg/minute thereafter. The authors conclude PaCO2 rises more rapidly in awake apnoeic humans than earlier (anaesthesia-based) estimates suggested, and that these values are better for estimating safe apnoea duration in conscious, critically ill patients.

Watch out: Breath-holding at functional residual capacity with FiO2 1.0 in 20 volunteers; end-tidal CO2 was used to estimate the arterial rise, and rates differ with starting lung volume, starting CO2 and metabolic rate.

Source: Primary human physiology study | Stock MC et al. The carbon dioxide rate of rise in awake apneic humans. J Clin Anesth. 1988. PMID: 3152423. Registry ID: none in the record (physiology study). MeSH: Adult · Apnea/blood · Carbon Dioxide/analysis,blood · Consciousness · Functional Residual Capacity/physiology · Humans · Hypercapnia/blood · Lung Volume Measurements · Models, Biological · Tidal Volume/physiology · Time Factors · Total Lung Capacity/physiology

Card 3 — Stock 1989 (anaesthetised, obstructed airway): PaCO2 rose 12 mm Hg in the first minute of apnoea, then 3.4 mm Hg per minute — slower than in awake subjects, and apnoeic oxygenation flows did not wash out meaningful CO2

Study: Primary human physiology study

Population: 14 consenting healthy adults under enflurane–oxygen anaesthesia (deep enough to prevent spontaneous ventilation, no neuromuscular blockade), whose tracheal tubes were clamped; arterial blood sampled before and at intervals to 300 seconds while oxygen saturation stayed above 0.92.

Summary: Stock 1989 (anaesthetised, obstructed airway): PaCO2 rose 12 mm Hg in the first minute of apnoea, then 3.4 mm Hg per minute — slower than in awake subjects, and apnoeic oxygenation flows did not wash out meaningful CO2

Result: The PaCO2 rise was best described by a logarithmic function; piecewise linear approximation gave a rise of 12 mm Hg during the first minute of apnoea and 3.4 mm Hg/minute thereafter. The authors state these values should be used when estimating apnoea duration from PaCO2 change in anaesthetised patients without ventilatory support, and that the oxygen flows used in earlier apnoeic-oxygenation work probably did not eliminate significant quantities of CO2 — that is, the rate is set by CO2 production and body CO2 stores, not by the oxygen flow.

Watch out: Anaesthetised patients with a clamped tube are not awake apnoeic patients — the two Stock cards deliberately bracket the states, and neither rate should be applied to the other population.

Source: Primary human physiology study | Stock MC et al. The PaCO2 rate of rise in anesthetized patients with airway obstruction. J Clin Anesth. 1989. PMID: 2516732. Registry ID: none in the record (physiology study). MeSH: Adult · Aged · Aged, 80 and over · Airway Obstruction/blood · Anesthesia, General · Apnea/blood · Carbon Dioxide/blood · Humans · Hydrogen-Ion Concentration · Middle Aged · Oxygen/blood · Partial Pressure · Probability · Time Factors

Card 4 — Synthesis: arterial CO2 rises logarithmically in apnoea — a fast first phase as arterial blood equilibrates with mixed venous CO2, then a steady climb set by metabolic CO2 production

Study: Synthesis

Population: Synthesis of Frumin 1959, Stock 1988 and Stock 1989, framed by Guyton & Hall Textbook of Medical Physiology and Ganong's Review of Medical Physiology (textbook framing, not evidence cards).

Summary: Synthesis: arterial CO2 rises logarithmically in apnoea — a fast first phase as arterial blood equilibrates with mixed venous CO2, then a steady climb set by metabolic CO2 production

Result: The carded human measurements agree on the shape: a rapid initial rise (Stock awake: 7 mm Hg in the first 10 seconds; Stock anaesthetised: 12 mm Hg in the first minute) reflecting equilibration of arterial with venous CO2, followed by a roughly linear rise — about 6 mm Hg/minute in awake apnoeic volunteers and 3.4 mm Hg/minute in anaesthetised patients with an obstructed airway. What determines the rate, on the carded evidence and the textbook account: metabolic CO2 production, the size and filling of body CO2 stores (hence the logarithmic shape), starting lung volume and CO2 level, and whether any CO2 is being eliminated — the oxygen flow of apnoeic oxygenation maintains oxygenation (Frumin) but does not meaningfully remove CO2 (Stock 1989). Textbook values for the steady phase (about 3–4 mm Hg/minute after the first minute in anaesthetised apnoea) are the textbook's account and match the anaesthetised measurement carded here; the awake rate measured by Stock is faster.

Watch out: Synthesis: the steady-phase rate varies with CO2 production and stores, so the quoted rates are for resting humans at resting lung volume, not for sepsis, exercise or children.

Source: Synthesis of Frumin MJ et al. Anesthesiology. 1959 (PMID: 13825447); Stock MC et al. J Clin Anesth. 1988 (PMID: 3152423); Stock MC et al. J Clin Anesth. 1989 (PMID: 2516732). Registry IDs: none in the records (classic physiology).