SourceMed · Shelf #6251 in the ask interface

Standing up: leg volume up 2.5% in 10 minutes, a brief 25% pressure dip, then a baroreflex resistance defence — the normal orthostatic response quantified

Shelf #6251 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1988–2010.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, how much blood pools in the legs on standing, and how do baroreflex responses defend arterial pressure over the first minutes upright?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Framed by Guyton & Hall (textbook framing, not evidence). Carded human measurements: healthy leg volume rises 2.48% over 10 minutes standing, bi-exponentially (Pannier 2010, N=16 healthy); the first seconds bring a transient 25% (23 mm Hg) pressure fall from a 36% fall in total peripheral resistance (Sprangers & Imholz 1991, N=8); the sustained defence is vasoconstrictor — systemic vascular resistance +33% at 7 minutes in non-fainters, with heart rate +20 beats/min at 2 minutes (ten Harkel & Wieling 1993, N=13) — against normal ranges defined in 92 healthy people with direct calf pooling demonstrated by radiotracer counting (Streeten 1988). The absolute pooled volume (roughly 500–700 mL) is given only as the textbook's account in the Synthesis, since no carded record prints it. The library's orthostatic shelves are drug-treatment shelves; the normal-response quantification was uncovered.

MeSH: Adult · Blood Pressure/physiology · Cardiac Output/physiology · Exercise/physiology · Humans · Hypotension, Orthostatic/physiopathology · Male · Posture · Vascular Resistance/physiology

Cards (5)

Card 1 — Pannier 2010: leg volume rose 2.48% over 10 minutes of quiet standing in 16 healthy people — a fast venous-pooling compartment plus a slow extravasation compartment

Study: Primary human physiology study

Population: 16 healthy individuals and 24 patients with varicose veins, studied prospectively with an optoelectric volume measurement system (Perometer) during 10 minutes standing. Only the healthy group's values are used for this shelf's question.

Summary: Pannier 2010: leg volume rose 2.48% over 10 minutes of quiet standing in 16 healthy people — a fast venous-pooling compartment plus a slow extravasation compartment

Result: During 10 minutes standing, leg volume increased significantly in the healthy group by 2.48% (varicose group 2.1%), in both upper and lower leg, with no significant right–left difference. The increase was rapid from the moment of standing and followed a bi-exponential course: a fast filling compartment (venous pooling) and a slow filling compartment reflecting extravasation, with further oedema forming over the course of a day. This is the carded direct quantification of pooling in healthy legs: the percentage is the record's number; the familiar absolute figure (roughly 500–700 mL shifted into the legs and splanchnic bed on standing) is the textbook's account (Guyton & Hall), given as such in the Synthesis.

Watch out: Percentage of leg volume, not millilitres — the record prints no absolute pooled volume, so the textbook millilitre figure appears only as the textbook's account in the Synthesis; the healthy subgroup is 16 people.

Source: Primary human physiology study | Pannier F, Rabe E. Optoelectric volume measurements to demonstrate volume changes in the lower extremities during orthostasis. Int Angiol. 2010. PMID: 20924340. Registry ID: none in the record (physiology study). MeSH: Anthropometry/methods · Case-Control Studies · Dizziness/diagnosis,pathology,physiopathology · Edema/diagnosis,pathology,physiopathology · Female · Germany · Humans · Lower Extremity/blood supply,pathology · Male · Middle Aged · Organ Size · Posture · Predictive Value of Tests · Prospective Studies · Time Factors · Venous Insufficiency/diagnosis,pathology,physiopathology

Card 2 — Sprangers & Imholz 1991: the first seconds upright — mean pressure transiently falls 25% (23 mm Hg) because total peripheral resistance falls 36%, before the baroreflex defence engages

Study: Primary human physiology study

Population: Eight healthy male subjects with beat-to-beat intra-arterial pressure measured on standing from supine, with stroke volume, cardiac output and total peripheral resistance computed by a pulse-contour method; passive tilting and a brief 3-second bout of cycling used as comparison manoeuvres; right atrial and oesophageal pressures measured in two subjects.

Summary: Sprangers & Imholz 1991: the first seconds upright — mean pressure transiently falls 25% (23 mm Hg) because total peripheral resistance falls 36%, before the baroreflex defence engages

Result: Standing elicited a transient 25% (23 mm Hg) fall in mean blood pressure, caused by a 36% fall in total peripheral resistance. Head-up tilt produced gradual changes reaching plateau levels in 20–30 seconds, and cycling produced a similar transient fall (17%, 18 mm Hg; resistance −41%). Right atrial pressure rose 10–15 mm Hg on standing without a matching oesophageal pressure change, pointing to the cardiopulmonary reflex as the primary effector of the initial peripheral vasodilation. That is, the very first event on standing is a brief vasodilator dip — the defence that follows has to overcome it, which is why the first-minutes response cannot be read off the initial seconds.

Watch out: Very small study (N=8; atrial pressures in only 2 subjects) using a pulse-contour computation — the mechanism attribution (cardiopulmonary reflex) is the authors' inference, stated as such on the face.

Source: Primary human physiology study | Sprangers RL et al. Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. J Appl Physiol. 1991. PMID: 2022542. Registry ID: none in the record (physiology study). MeSH: Adult · Blood Pressure/physiology · Cardiac Output/physiology · Exercise/physiology · Humans · Hypotension, Orthostatic/physiopathology · Male · Posture · Vascular Resistance/physiology

Card 3 — ten Harkel & Wieling 1993: over the first minutes upright, non-fainters defend pressure by raising systemic vascular resistance (+33% at 7 minutes) while stroke volume and cardiac output responses match those of fainters

Study: Primary human physiology study

Population: 13 healthy males without a history of syncope, studied during prolonged standing with Finapres blood pressure, pulse-contour stroke volume, cardiac output and systemic vascular resistance, and spectral analysis of pressure and heart-rate variability. Three fainted after 10–13 minutes; ten stayed upright for 20 minutes.

Summary: ten Harkel & Wieling 1993: over the first minutes upright, non-fainters defend pressure by raising systemic vascular resistance (+33% at 7 minutes) while stroke volume and cardiac output responses match those of fainters

Result: The initial (first 30 seconds) adjustment was comparable for blood pressure, but the rebound bradycardia was smaller in fainters (heart rate at 22 seconds +13 ± 10 beats/min above control vs +1 ± 5 in non-fainters). Upright heart rate at 2 minutes was higher in fainters (+31 ± 2 vs +20 ± 5 beats/min), and blood pressure at 7 minutes was lower. Stroke volume and cardiac output responses were comparable between groups, but systemic vascular resistance gradually decreased in fainters from 5 minutes to fainting, versus +33 ± 19% at 7 minutes in non-fainters. The defence of pressure over the first minutes is therefore principally a vasoconstrictor (resistance) defence, and its failure — not a failure of cardiac output — is what precedes fainting.

Watch out: Only 13 subjects and just 3 fainters — the fainter/non-fainter contrast is hypothesis-grade; the non-fainter defence values (+33% resistance, +20 beats/min) are the shelf's normative numbers.

Source: Primary human physiology study | ten Harkel AD et al. Differences in circulatory control in normal subjects who faint and who do not faint during orthostatic stress. Clin Auton Res. 1993. PMID: 8324374. Registry ID: none in the record (physiology study). MeSH: Adult · Blood Pressure/physiology · Cardiac Output/physiology · Electrocardiography · Fingers/blood supply · Heart Rate/physiology · Humans · Hypotension, Orthostatic · Male · Regional Blood Flow/physiology · Respiration/physiology · Stress, Physiological/physiopathology · Stroke Volume/physiology · Syncope/physiopathology

Card 4 — Streeten 1988: the normal ranges for orthostatic pressure and heart-rate change were defined in 92 healthy people aged 18–64 — and gamma counting over the calf directly demonstrated gravitational pooling in the legs on standing

Study: Primary human physiology study

Population: 92 individuals aged 18 to 64 years in whom the normal ranges of orthostatic blood-pressure and heart-rate changes were defined; plus 34 symptomatic individuals with intact sympathetic function (used here only for the pooling measurement method), in whom red-cell labelling with technetium-99m pertechnetate and external gamma counting over a fixed calf site compared recumbent and standing blood content.

Summary: Streeten 1988: the normal ranges for orthostatic pressure and heart-rate change were defined in 92 healthy people aged 18–64 — and gamma counting over the calf directly demonstrated gravitational pooling in the legs on standing

Result: External gamma counting showed excessive gravitational pooling of blood in the legs of the symptomatic subgroups tested (five patients with orthostatic diastolic hypertension, four with pulse-pressure narrowing, ten with orthostatic tachycardia alone), against the normal ranges defined in the 92-person reference group; plasma norepinephrine was usually normal recumbent and rose above normal limits during 15–30 minutes standing in the 18 patients so observed. The card establishes two things for this shelf: a healthy reference distribution for the upright pressure/heart-rate response, and direct radiotracer demonstration that blood physically pools in the calf on standing — excessive in the patients, present as the normal phenomenon the baroreflex defence exists to counter.

Watch out: The pooling demonstration was in symptomatic patients, not the 92-person healthy reference group — the card separates the two uses explicitly, and 'excessive' pooling in patients should not be read as the healthy volume.

Source: Primary human physiology study (reference-range and pooling-measurement study) | Streeten DH et al. Abnormal orthostatic changes in blood pressure and heart rate in subjects with intact sympathetic nervous function: evidence for excessive venous pooling. J Lab Clin Med. 1988. PMID: 3343547. Registry ID: none in the record (physiology study). MeSH: Adolescent · Adult · Blood Circulation · Blood Pressure · Blood Volume · Erythrocyte Volume · Female · Gravity Suits · Heart Rate · Humans · Hypotension, Orthostatic/blood,physiopathology,therapy · Male · Middle Aged · Norepinephrine/blood · Osmolar Concentration · Reference Values · Sympathetic Nervous System/physiopathology · Veins

Card 5 — Synthesis: on standing, several hundred millilitres pool in the legs within seconds to minutes; pressure is defended first against a brief vasodilator dip, then by baroreflex vasoconstriction

Study: Synthesis

Population: Synthesis of Pannier 2010, Sprangers 1991, ten Harkel 1993 and Streeten 1988, framed by Guyton & Hall Textbook of Medical Physiology (textbook framing, not an evidence card). The library's orthostatic shelves are drug-treatment shelves; this shelf quantifies the normal response only.

Summary: Synthesis: on standing, several hundred millilitres pool in the legs within seconds to minutes; pressure is defended first against a brief vasodilator dip, then by baroreflex vasoconstriction

Result: The sequence the carded human studies measure: (1) Pooling — leg volume rises rapidly on standing, +2.48% over 10 minutes in healthy legs (Pannier), bi-exponential (fast venous filling, slow extravasation); radiotracer counting confirms blood physically accumulating in the calf (Streeten). The textbook account (Guyton & Hall) puts the pooled volume at roughly 500–700 mL into the dependent veins — presented as the textbook's account, since no carded record prints an absolute millilitre figure. (2) The initial dip — mean pressure transiently falls 25% in the first seconds because total peripheral resistance falls 36%, a cardiopulmonary-reflex vasodilation (Sprangers). (3) The defence — over the following minutes the arterial baroreflex raises systemic vascular resistance (+33% at 7 minutes in those who stay upright, ten Harkel) with a moderate heart-rate rise (+20 beats/min at 2 minutes), holding pressure within the normal ranges Streeten defined in 92 healthy people; when the resistance response instead fades, fainting follows. Sjöstrand's classic blood-volume distribution work and Rowell's orthostasis programme are the historical anchors for this picture in the textbook framing; the carded numbers above are the fetched human measurements.

Watch out: Synthesis: no carded record prints an absolute pooled millilitre volume; that figure is Guyton & Hall's account and is labelled as such wherever it appears.

Source: Synthesis of Pannier F, Rabe E. Int Angiol. 2010 (PMID: 20924340); Sprangers RL et al. J Appl Physiol. 1991 (PMID: 2022542); ten Harkel AD et al. Clin Auton Res. 1993 (PMID: 8324374); Streeten DH et al. J Lab Clin Med. 1988 (PMID: 3343547). Registry IDs: none in the records (physiology studies).