SourceMed · Shelf #6304 in the ask interface

Coronary autoregulation (physiology): flow stays constant while pressure falls — until the plateau breaks — and in humans the break point shifts upward with hypertension and hypertrophy (flow fell 26% once pressure reached 90–80 mm Hg), with adenosine and K-ATP-channel metabolic coupling doing the day-to-day work

Shelf #6304 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1990–2004.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How does coronary autoregulation hold myocardial blood flow constant across perfusion pressures, which mediators (adenosine, metabolic coupling) dominate, and where does the autoregulatory range break in humans?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED (textbook framing: Guyton & Hall Textbook of Medical Physiology, coronary-circulation chapter). In the textbook account, coronary flow is autoregulated: across a wide range of perfusion pressures, arteriolar resistance adjusts so flow matches myocardial oxygen demand — metabolic coupling — with adenosine, released as ATP is consumed, as the classic mediator, alongside other local signals including ATP-sensitive potassium (K-ATP) channels. Below the lower limit of the range, vessels are maximally dilated and flow becomes pressure-dependent. The carded human studies measure the plateau, its break point, and its mediators in people. Lowering coronary perfusion pressure stepwise in patients with normal epicardial arteries left great-cardiac-vein flow unchanged down to the 60–70 mm Hg endpoints in controls and in hypertensives without hypertrophy — but in hypertensive patients with left ventricular hypertrophy, flow began to fall at 90–80 mm Hg and was down 26% at the endpoint: the lower limit shifts upward when baseline flow is high and arteriolar dilation is impaired (Polese 1991). For mediators: blocking adenosine receptors with theophylline cut human coronary flow by 23% across rest, hypoxia and exercise (Edlund 1995), and blocking K-ATP channels with intracoronary glibenclamide blunted pacing-induced metabolic vasodilation (Farouque 2004); exogenous adenosine itself reproduces near-maximal human coronary vasodilation (Wilson 1990). SCOPE: this shelf covers the autoregulatory plateau and its mediators only — the magnitude of coronary flow reserve is a separate question, deliberately not built here. PHYSIOLOGY — ESTABLISHED.

MeSH: Blood Pressure/physiology · Cardiomegaly/physiopathology · Coronary Circulation/physiology · Coronary Vessels/physiopathology · Homeostasis/physiology · Humans · Hypertension/physiopathology · Male · Middle Aged · Nitroprusside · Thermodilution · Vascular Resistance/physiology

Cards (5)

Card 1 — Polese 1991: human coronary flow held constant as perfusion pressure was lowered stepwise — except in hypertensive hypertrophy, where flow began falling at 90–80 mm Hg and was down 26% at the endpoint

Study: Primary human physiology study (stepwise perfusion-pressure lowering with coronary sinus/great cardiac vein flow measurement)

Population: 24 men with effort-induced angina and angiographically normal left epicardial branches: 9 normotensive controls, 7 hypertensive patients with normal left ventricular mass (group I), and 8 hypertensive patients with augmented LV mass index from concentric hypertrophy (group II). Flow in the great cardiac vein was measured by thermodilution at baseline and during stepwise decreases in coronary perfusion pressure (5 mm Hg every 5 minutes) produced by titrated intravenous nitroprusside, to endpoints of 60 mm Hg in controls and 70 mm Hg in hypertensives.

Summary: Polese 1991: human coronary flow held constant as perfusion pressure was lowered stepwise — except in hypertensive hypertrophy, where flow began falling at 90–80 mm Hg and was down 26% at the endpoint

Result: Baseline flow averaged 102 ml/min in normotensives, 104 ml/min in hypertensive group I and 148 ml/min in hypertensive group II. At the endpoints, flow was similar to baseline in the controls and in group I — the autoregulatory plateau, demonstrated directly in humans. In group II, coronary flow started to decline and myocardial oxygen extraction started to rise at perfusion pressures of 90–80 mm Hg, and at the endpoint flow was reduced by 26% (p < 0.01 from baseline). The patterns were not explained by changes in tension-time index or heart rate. The authors conclude that hypertension (reduced arteriolar dilator ability) plus hypertrophy (augmented baseline flow) shifts the point of exhaustion of coronary reserve to a higher perfusion pressure.

Watch out: Great cardiac vein flow samples the anterior left ventricular territory, not whole-heart flow, and nitroprusside has its own vascular actions; within those limits this is the direct human demonstration of the plateau and of its upward-shifted lower limit in hypertrophy. The study's framing touches coronary reserve, but it is carded here only for the autoregulatory range — reserve magnitude is a separate shelf's question.

Source: Polese A et al. Upward shift of the lower range of coronary flow autoregulation in hypertensive patients with hypertrophy of the left ventricle. Circulation. 1991. PMID: 1825626. Registry ID: none in the record. MeSH: Blood Pressure/physiology · Cardiomegaly/physiopathology · Coronary Circulation/physiology · Coronary Vessels/physiopathology · Homeostasis/physiology · Humans · Hypertension/physiopathology · Male · Middle Aged · Nitroprusside · Thermodilution · Vascular Resistance/physiology

Card 2 — Wilson 1990: adenosine in humans reproduces maximal coronary vasodilation — a 16 µg intracoronary bolus raised flow velocity 4.6 ± 0.7-fold, matching papaverine

Study: Primary human physiology study (intracoronary/intravenous adenosine dose-response with Doppler flow velocity)

Population: Patients undergoing coronary studies with coronary blood flow velocity (CBFV) measured by a 3F coronary Doppler catheter: normal left coronary arteries (n = 20) and right coronary arteries (n = 5) for intracoronary boluses (2–16 µg), 6 patients for intracoronary infusions (10–240 µg/min), 25 normal patients for intravenous infusions (35–140 µg/kg/min), and 8 patients with microvascular vasodilator dysfunction; maximal CBFV was defined against intracoronary papaverine (4.5 ± 0.2 × resting CBFV).

Summary: Wilson 1990: adenosine in humans reproduces maximal coronary vasodilation — a 16 µg intracoronary bolus raised flow velocity 4.6 ± 0.7-fold, matching papaverine

Result: In normal left coronary arteries, 16 µg adenosine boluses caused hyperaemia similar to papaverine (4.6 ± 0.7 × resting CBFV); 12 µg boluses did the same in the right coronary artery (4.4 ± 1.0 × resting). Intracoronary infusions of 80 µg/min or more also caused maximal hyperaemia (4.4 ± 0.1 × resting), with only a minimal fall in arterial pressure (−6 ± 2 mm Hg) at up to 240 µg/min and no significant heart-rate or ECG change; hyperaemia was much briefer after adenosine than after papaverine. Intravenous adenosine at 140 µg/kg/min matched papaverine in 84% of patients. The endogenous mediator, given exogenously, can drive the human coronary bed to its vasodilator ceiling — the pharmacologic counterpart of the metabolic signal.

Watch out: This card is carded for adenosine's mediator credentials — that the human coronary bed responds to it fully and briefly — not as a measurement of coronary flow reserve, whose magnitude is a separate question excluded from this shelf's scope. Exogenous responsiveness alone would not prove the endogenous role; the theophylline card supplies the blockade half of the argument.

Source: Wilson RF et al. Effects of adenosine on human coronary arterial circulation. Circulation. 1990. PMID: 2225364. Registry ID: none in the record. MeSH: *Adenosine/administration & dosage,pharmacology · Blood Flow Velocity/drug effects · Coronary Circulation/drug effects,physiology · Coronary Disease/diagnosis · Dose-Response Relationship, Drug · Humans · Hyperemia/chemically induced · Infusions, Intra-Arterial · Infusions, Intravenous · Injections, Intra-Arterial · Papaverine

Card 3 — Edlund 1995: blocking adenosine receptors with theophylline cut human coronary sinus flow by 23% at rest, in hypoxia and in exercise (N = 6)

Study: Primary human physiology study (adenosine-receptor blockade with coronary sinus flow measurement) — N = 6

Population: 6 healthy subjects in whom coronary sinus blood flow (thermodilution) and cardiac oxygen extraction were measured breathing room air at rest and breathing 12% oxygen at rest and during light exercise, on two occasions — one during theophylline infusion at a dose lacking effects on myocardial work. N = 6, printed on the face as the physiology labelling rule requires.

Summary: Edlund 1995: blocking adenosine receptors with theophylline cut human coronary sinus flow by 23% at rest, in hypoxia and in exercise (N = 6)

Result: Basal coronary sinus flow was 118 (67–168) ml/min; breathing 12% oxygen (arterial saturation 83% at rest, 77% in exercise) raised flow to 167 (93–214) ml/min at rest and 261 (179–343) ml/min in exercise, while oxygen extraction fell. Theophylline markedly attenuated the flow response to exogenous adenosine and decreased coronary sinus flow to 89 (58–119), 120 (79–161) and 190 (162–218) ml/min in the three states — an overall decrease of 23% (a relative reduction; P < 0.05), with calculated coronary vascular conductance also down 23% (P < 0.05) and oxygen extraction up 15% (P < 0.001). Endogenous adenosine therefore carries a measurable share of human coronary tone at rest and under metabolic stress — blockade evidence, the strongest kind for a mediator.

Watch out: N = 6, and theophylline is not perfectly selective — but the dose was chosen to lack myocardial-work effects and it verifiably blocked exogenous adenosine responses in the same subjects, so the 23% flow fall is reasonably attributed to adenosine-receptor blockade. A 23% share also means adenosine is a contributor, not the whole of metabolic coupling — the K-ATP card shows another limb.

Source: Edlund A et al. Theophylline increases coronary vascular tone in humans: evidence for a role of endogenous adenosine in flow regulation. Acta physiologica Scandinavica. 1995. PMID: 8619329. Registry ID: none in the record. MeSH: Adenosine/pharmacology,physiology · Adult · Blood Pressure/physiology · Coronary Circulation/drug effects · Coronary Vessels/drug effects · Female · Heart Rate/physiology · Humans · Hypoxia/physiopathology · Male · Myocardium/metabolism,ultrastructure · Oxygen/blood · Oxygen Consumption/drug effects,physiology · Oxyhemoglobins/metabolism · Physical Exertion/physiology · Purinergic P1 Receptor Antagonists · Respiration/drug effects,physiology · Theophylline/blood,pharmacology · Vasodilator Agents/blood,pharmacology

Card 4 — Farouque 2004: blocking K-ATP channels with intracoronary glibenclamide reduced resting coronary flow 9% and blunted pacing-induced metabolic vasodilation in 17 patients

Study: Primary human physiology study (intracoronary K-ATP blockade during pacing-induced metabolic vasodilation)

Population: 17 patients (12 men; age 58 ± 10 years) studied in an angiographically smooth coronary artery after successful percutaneous intervention to another vessel, with coronary blood velocity by Doppler guidewire before and after subselective intracoronary glibenclamide (40 µg/min) versus vehicle; metabolic vasodilation was induced by 2 minutes of rapid right ventricular pacing and the hyperaemic time course recorded for 2 minutes.

Summary: Farouque 2004: blocking K-ATP channels with intracoronary glibenclamide reduced resting coronary flow 9% and blunted pacing-induced metabolic vasodilation in 17 patients

Result: Compared with vehicle, glibenclamide reduced resting coronary blood flow by 9% (P = 0.04) and increased resting coronary vascular resistance by 15% (P = 0.03). It reduced pacing-induced peak flow (50.8 ± 6.8 vs 42.0 ± 5.4 ml/min, P = 0.001), peak flow corrected for baseline (25.1 ± 4.6 vs 17.6 ± 3.1 ml/min, P = 0.01), and total hyperaemic volume over 2 minutes (area under the flow–time curve 3,535 ± 397 vs 3,027 ± 326 ml, P = 0.001), while minimum coronary vascular resistance rose (2.6 ± 0.3 vs 3.1 ± 0.3 mm Hg/ml/min, P = 0.002). Vascular K-ATP channels — a downstream effector that several metabolic signals converge on — are part of how the human coronary bed matches flow to demand.

Watch out: Patients with coronary disease (studied in a smooth artery after PCI elsewhere), and glibenclamide blockade is partial pharmacology, not a knockout: the finding is that K-ATP channels contribute measurably to human metabolic vasodilation, alongside — not instead of — adenosine.

Source: Farouque HM et al. Effect of ATP-sensitive potassium channel inhibition on coronary metabolic vasodilation in humans. Arteriosclerosis, thrombosis, and vascular biology. 2004. PMID: 15016638. Registry ID: none in the record. MeSH: Adenosine Triphosphate/physiology · Aged · Angioplasty, Balloon, Coronary · Cardiac Catheterization · Cardiac Pacing, Artificial · Coronary Angiography · Coronary Artery Disease/metabolism,therapy · Coronary Circulation/drug effects · Coronary Vessels/drug effects,metabolism · Female · Glyburide/pharmacology · Humans · Hyperemia/metabolism · Ion Transport/drug effects · Laser-Doppler Flowmetry · Male · Middle Aged · Myocardium/metabolism · Potassium/metabolism · Potassium Channel Blockers/pharmacology · Potassium Channels/drug effects,physiology · Receptors, Drug/drug effects,physiology · Reproducibility of Results · Vasodilation/drug effects

Card 5 — Synthesis: a pressure-independent plateau, an upward-shifted break point in hypertrophy, and redundant metabolic mediators

Study: Synthesis

Population: Synthesis of the carded human studies, framed by Guyton & Hall Textbook of Medical Physiology (coronary-circulation chapter). No new data.

Summary: Synthesis: a pressure-independent plateau, an upward-shifted break point in hypertrophy, and redundant metabolic mediators

Result: In humans, coronary flow is held constant as perfusion pressure falls — directly demonstrated to 60–70 mm Hg endpoints in non-hypertrophied hearts (PMID 1825626) — because arteriolar resistance tracks metabolic demand. The plateau's lower limit is not fixed: with hypertension plus hypertrophy it shifts up to roughly 90–80 mm Hg, below which flow fell 26% (PMID 1825626). The coupling is mediator-redundant: adenosine can drive the bed to maximum (PMID 2225364) and its blockade removes about a quarter of flow (PMID 8619329), while K-ATP channel blockade independently blunts metabolic vasodilation (PMID 15016638) — parallel pathways, which is why no single antagonist abolishes autoregulation. PHYSIOLOGY — ESTABLISHED.

Watch out: Scope held as commissioned: this shelf covers the autoregulatory plateau and its mediators only. How large coronary flow reserve is, and what reduces it, is a separate question (slate-4 row 185) for a later wave and is not answered here.

Source: Synthesis of the cards on this shelf (PMIDs 1825626, 2225364, 8619329, 15016638), framed by Guyton & Hall Textbook of Medical Physiology. No additional source.