SourceMed · Shelf #6353 in the ask interface
Oxygen delivery, the Fick principle and DO2crit: above a critical delivery, consumption is set by metabolic demand and extraction rises as delivery falls; below it, consumption falls with delivery and lactate rises — the biphasic relation is demonstrated in humans, with the threshold near 330 mL/min/m² in anaesthetised surgical patients but only 3.8–4.5 mL/min/kg in dying critically ill patients, and sepsis did not move it
Shelf #6353 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1983–1998.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are oxygen delivery and oxygen consumption, what determines critical oxygen delivery (DO2crit), and when does oxygen consumption become supply-dependent?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED (textbook framing: Guyton & Hall Textbook of Medical Physiology and Boron & Boulpaep Medical Physiology, circulation/tissue-oxygen chapters). The textbook account: oxygen delivery (DO2) is cardiac output multiplied by arterial oxygen content, and oxygen consumption (VO2) follows from the Fick principle — VO2 = cardiac output × (arterial − mixed venous oxygen content). As delivery falls, tissues first compensate by extracting a larger fraction of the delivered oxygen, so consumption stays constant (supply independence); below a critical delivery (DO2crit), extraction can rise no further, consumption falls in proportion to delivery (supply dependence), and anaerobic metabolism with lactate production begins. The carded human studies demonstrate the biphasic curve directly and show the threshold is context-dependent, not a universal constant. In 58 anaesthetised surgical patients the critical value was 330 mL/min/m² (8.2 mL/min/kg), with consumption plateauing at 109 ± 16 mL/min/m² above it (Shibutani 1983). In 18 critically ill patients studied as life support was withdrawn, the biphasic relation appeared in every individual, with DO2crit of 3.8 ± 1.5 (septic) vs 4.5 ± 1.3 mL/min/kg (nonseptic) — no significant difference, and considerably lower than older pooled-group estimates (Ronco 1993). And supply dependence is a state, not a trait: the same 10 septic patients showed VO2 tracking DO2 during shock (extraction fixed) but not after recovery, when extraction adjusted and VO2 stayed constant (Friedman 1998). Any single textbook DO2crit number is therefore the textbook's simplification; the carded human values are the two measured settings above. PHYSIOLOGY — ESTABLISHED.
MeSH: Adult · Aged · Bacterial Infections/complications,metabolism,physiopathology,therapy · Calorimetry, Indirect · Cell Hypoxia · Cohort Studies · Critical Illness · Female · Humans · Lactates/blood · Lactic Acid · Male · Middle Aged · Models, Biological · Multiple Organ Failure/etiology,prevention & control · *Oxygen Consumption · Oxygen Inhalation Therapy/standards · Reference Values
Cards (4)
Card 1 — Shibutani 1983: in 58 anaesthetised patients the critical oxygen delivery was 330 mL/min/m² (8.2 mL/min/kg) — below it VO2 fell in proportion to DO2, above it VO2 plateaued at 109 ± 16
Study: Primary human physiology study (DO2/VO2 relation under anaesthesia) — N = 58 patients, 99 measurement sets
Population: 58 patients anaesthetised (diazepam, pancuronium, fentanyl) for cardiac surgery, with 99 sets of haemodynamic measurements taken after sternotomy and before cardiopulmonary bypass, spanning a range of oxygen deliveries.
Summary: Shibutani 1983: in 58 anaesthetised patients the critical oxygen delivery was 330 mL/min/m² (8.2 mL/min/kg) — below it VO2 fell in proportion to DO2, above it VO2 plateaued at 109 ± 16
Result: Regression analysis identified a critical DO2 of 330 mL/min/m², or 8.2 mL/min/kg. Below it, VO2 decreased in proportion to DO2 (VO2 = 0.36 × DO2 − 11.20; n=30, r=0.77, P<10⁻⁶). Above it, VO2 plateaued at 109 ± 16 mL/min/m² (n=69, r=−0.02), while mixed venous oxygen tension kept falling as DO2 fell — compensatory extraction rising until it could rise no more. The authors concluded that a fall in VO2 below the critical delivery signals tissue oxygen deprivation.
Watch out: Anaesthetised, paralysed surgical patients have low metabolic demand, which is part of why their threshold reads as it does; DO2 and VO2 here share cardiac output in their calculation (mathematical coupling), a caveat the Ronco card's independent calorimetry addresses.
Source: Shibutani K et al. Critical level of oxygen delivery in anesthetized man. Critical care medicine. 1983. PMID: 6409505. Registry ID: none in the record. MeSH: Adult · Aged · *Anesthesia, General · Carbon Dioxide/blood · Coronary Artery Bypass · Female · Hemodynamics · Humans · Hydrogen-Ion Concentration · Male · Middle Aged · Oxygen/administration & dosage,blood · Oxygen Consumption
Card 2 — Ronco 1993: measured individually as support was withdrawn, DO2crit was 3.8 ± 1.5 mL/min/kg in septic and 4.5 ± 1.3 in nonseptic patients — sepsis did not alter the threshold or extraction ability
Study: Primary human physiology study (individual biphasic DO2/VO2 curves, calorimetry) — N = 18 (9 septic, 9 nonseptic)
Population: 18 critically ill patients (9 septic, 9 nonseptic) in two university intensive care units, studied with simultaneous indirect calorimetry (VO2), Fick-calculated DO2 and arterial lactate measured every 5–20 minutes while life support was discontinued; sepsis was confirmed by cultures and autopsy evidence of a source.
Summary: Ronco 1993: measured individually as support was withdrawn, DO2crit was 3.8 ± 1.5 mL/min/kg in septic and 4.5 ± 1.3 in nonseptic patients — sepsis did not alter the threshold or extraction ability
Result: In all septic and eight nonseptic patients, DO2 and VO2 showed a biphasic relationship. There were no differences between septic and nonseptic patients in critical DO2 (3.8 ± 1.5 vs 4.5 ± 1.3 mL/min/kg; P>.28), critical oxygen extraction ratio (0.61 ± 0.05 vs 0.59 ± 0.16; P>.64) or maximal extraction ratio (0.74 ± 0.08 vs 0.80 ± 0.11; P>.29), with over 90% power to detect a 2 mL/min/kg difference in critical DO2. The authors concluded the individually measured critical delivery is considerably lower than previously reported from pooled group data, that sepsis does not alter DO2crit or tissue extraction ability, and that pushing DO2 to supranormal levels hoping to raise VO2 may be inappropriate.
Watch out: Measurements were made during withdrawal of life support in dying patients — the only setting in which the full curve to very low delivery can be observed in humans, and the reason the values sit far below the anaesthetised-surgical threshold. VO2 by calorimetry is independent of the Fick calculation, answering the coupling criticism of earlier pooled studies.
Source: Ronco JJ et al. Identification of the critical oxygen delivery for anaerobic metabolism in critically ill septic and nonseptic humans. JAMA. 1993. PMID: 8411504. Registry ID: none in the record. MeSH: Adult · Aged · Bacterial Infections/complications,metabolism,physiopathology,therapy · Calorimetry, Indirect · Cell Hypoxia · Cohort Studies · Critical Illness · Female · Humans · Lactates/blood · Lactic Acid · Male · Middle Aged · Models, Biological · Multiple Organ Failure/etiology,prevention & control · *Oxygen Consumption · Oxygen Inhalation Therapy/standards · Reference Values
Card 3 — Friedman 1998: the same 10 septic patients were supply-dependent during shock (VO2 121 → 165 as DO2 rose, extraction fixed) and supply-independent after recovery (VO2 unchanged, extraction adjusted)
Study: Primary human physiology study (within-patient shock vs recovery comparison) — N = 10
Population: 10 critically ill adults (55 ± 19 years) whose haemodynamic and blood-gas data were reviewed retrospectively in two phases: during an episode of septic shock (phase A), when DO2 was acutely altered by fluids, vasoactive drugs or PEEP, and after recovery from the episode (phase B).
Summary: Friedman 1998: the same 10 septic patients were supply-dependent during shock (VO2 121 → 165 as DO2 rose, extraction fixed) and supply-independent after recovery (VO2 unchanged, extraction adjusted)
Result: In phase A, changes in VO2 (121 ± 32 vs 165 ± 36 mL/min/m², P<0.001) paralleled changes in DO2 (415 ± 153 vs 607 ± 217 mL/min/m², P<0.001) while oxygen extraction stayed stable (31.9 ± 11.2 vs 30.2 ± 8.9%). In phase B, DO2 changes (412 ± 118 vs 526 ± 152, P<0.001) were met by opposite changes in extraction (36.1 ± 4.2 vs 28.9 ± 4.9%, P<0.001) and VO2 was unchanged (147 ± 35 vs 149 ± 33). The VO2/DO2 slope was greater in phase A than phase B (0.26 ± 0.09 vs 0.08 ± 0.08, P<0.004), and lactate was higher in phase A (3.3 ± 1.8 vs 1.6 ± 0.6 mEq/L, P<0.05). Supply dependency characterised the shock state in the same patients who later showed independence.
Watch out: Retrospective, and DO2/VO2 share measured variables here, so the phase contrast (same patients, same methods, opposite pattern) carries the inference rather than either phase alone. Carded for that within-patient demonstration that supply dependence comes and goes with the shock state.
Source: Friedman G et al. Oxygen supply dependency can characterize septic shock. Intensive care medicine. 1998. PMID: 9539067. Registry ID: none in the record. MeSH: Adult · Aged · Critical Illness · Diagnosis, Differential · Female · *Hemodynamics · Humans · Lactic Acid/blood · Male · Middle Aged · Oxygen/blood · *Oxygen Consumption · Retrospective Studies · Shock, Septic/blood,diagnosis
Estimate type: adjusted estimate, as stated in the card.
Card 4 — Synthesis: one biphasic curve, two regimes — extraction compensates until DO2crit, then consumption is delivery's prisoner and lactate testifies
Study: Synthesis
Population: Synthesis of the carded human studies, framed by Guyton & Hall Textbook of Medical Physiology and Boron & Boulpaep Medical Physiology. No new data.
Summary: Synthesis: one biphasic curve, two regimes — extraction compensates until DO2crit, then consumption is delivery's prisoner and lactate testifies
Result: The Fick framework (textbook account) predicts exactly what human studies show: a plateau where VO2 is demand-set and extraction absorbs delivery changes, and a slope where VO2 tracks DO2. The threshold was 330 mL/min/m² in anaesthetised surgical patients (PMID 6409505) and roughly half that per kilogram in dying critically ill patients, with sepsis making no difference to the threshold or to maximal extraction (PMID 8411504) — yet supply dependence itself is a reversible feature of the shock state (PMID 9539067). DO2crit is therefore a property of the patient's metabolic state, not a universal constant, and any single quoted number should be read with its setting attached. PHYSIOLOGY — ESTABLISHED.
Watch out: Scope: whole-body delivery/consumption physiology. What limits maximal oxygen uptake in exercise (cardiac output vs extraction) is pack #6248, and supranormal-delivery resuscitation trials are treatment shelves, not this physiology.
Source: Synthesis of the cards on this shelf (PMIDs 6409505, 8411504, 9539067), framed by Guyton & Hall Textbook of Medical Physiology and Boron & Boulpaep Medical Physiology. No additional source.