SourceMed · Shelf #6359 in the ask interface
Hepatic extraction ratio: high-extraction drugs are flow-limited and lost to first pass, low-extraction drugs are capacity-limited — shown in humans by what a portacaval shunt does to each kind
Shelf #6359 · Liver & gut
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1976–2007.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What is the hepatic extraction ratio, how does it determine the first-pass effect and the difference between high- and low-extraction drugs, and how do liver blood flow versus intrinsic clearance each limit hepatic clearance?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED. The textbook account (Guyton & Hall; Boron & Boulpaep) is the framing: the extraction ratio E is the fraction of drug removed in one pass through the liver; hepatic clearance equals liver blood flow times E; oral bioavailability falls toward 1 − E, which is the first-pass effect. For a high-extraction drug E approaches 1, clearance tracks blood flow, and most of an oral dose never reaches the systemic circulation; for a low-extraction drug clearance tracks intrinsic clearance — enzyme capacity and unbound fraction — and barely notices flow. The carded human studies demonstrate each pole in people. A surgical portacaval shunt that cut hepatic blood flow by 65% halved the systemic clearance of high-extraction indocyanine green and lidocaine in milder cirrhosis while leaving intrinsic clearance unchanged and driving oral bioavailability to 1, and left the low-extraction aminopyrine breath test untouched in both severity groups (Pomier-Layrargues 1986, n=35). In 99 healthy volunteers, apparent oral clearance of the CYP3A probes midazolam and alfentanil ran roughly 4-fold and 2.5-fold above their systemic clearances — first pass measured, not theorised (Kharasch 2007). And the classic paediatric disposition study found the same high-extraction, large-first-pass behaviour for propranolol in children, with wide individual variability (Wilson 1976).
MeSH: Administration, Oral · Adult · Aged · Aminopyrine · Biological Availability · Breath Tests · Cytochrome P-450 CYP3A · Female · Humans · Indocyanine Green/metabolism · Lidocaine/metabolism · Liver/blood supply · Liver Cirrhosis/metabolism · Male · Middle Aged · Midazolam/pharmacokinetics · Portacaval Shunt, Surgical
Cards (4)
Card 1 — Pomier-Layrargues 1986: a portacaval shunt cutting liver blood flow 65% halved clearance of high-extraction drugs in milder cirrhosis, left intrinsic clearance unchanged, and did not touch the low-extraction aminopyrine test
Study: Human physiological study (pre/post portacaval shunt drug-disposition study in cirrhosis), Gastroenterology 1986
Population: 35 patients with cirrhosis studied before and 18 months after portacaval shunt surgery — 14 with slight liver dysfunction (indocyanine green extraction ratio above 0.25, group 1) and 21 with severe disease (extraction ratio below 0.25, group 2) — with lidocaine clearance and bioavailability, indocyanine green clearance, aminopyrine breath test and hepatic blood flow measured.
Summary: Pomier-Layrargues 1986: a portacaval shunt cutting liver blood flow 65% halved clearance of high-extraction drugs in milder cirrhosis, left intrinsic clearance unchanged, and did not touch the low-extraction aminopyrine test
Result: Hepatic blood flow fell by about 65% in both groups after shunt. In group 1, indocyanine green systemic clearance fell from 9.10 ± 0.68 to 4.40 ± 0.34 mL/min/kg (P < 0.05) while its intrinsic clearance was unchanged; lidocaine systemic clearance fell from 7.93 ± 0.93 to 5.09 ± 0.33 mL/min/kg (P < 0.05), intrinsic clearance again unchanged, and lidocaine bioavailability rose from 0.601 ± 0.076 to 1 — first pass abolished when blood bypassed the liver. In group 2 (severe disease), flow reduction had only minimal effects: indocyanine green systemic clearance fell slightly (3.90 to 2.28 mL/min/kg) and lidocaine clearance was unchanged. The aminopyrine breath test — a low-extraction, capacity-limited probe — was not affected by surgery in either group. The authors concluded flow reduction notably reduces clearance of high-extraction drugs when liver function is relatively preserved, and matters little once disease is severe.
Watch out: A surgical-shunt experiment in cirrhosis, not healthy liver: it isolates the flow-versus-capacity contrast precisely because the shunt changes flow and bypass at once, but extraction behaviour in non-cirrhotic liver is inferred from the group-1 pattern rather than measured in health.
Source: Pomier-Layrargues G et al. Effect of portacaval shunt on drug disposition in patients with cirrhosis. Gastroenterology. 1986. PMID: 3710065. Registry ID: none in the record. MeSH: Adult · Aged · Aminopyrine · Biological Availability · Breath Tests · Female · Humans · Indocyanine Green/metabolism · Lidocaine/metabolism · Liver/blood supply · Liver Cirrhosis/metabolism · Male · Middle Aged · Portacaval Shunt, Surgical
Card 2 — Kharasch 2007: in 99 healthy volunteers, apparent oral clearance of midazolam ran about 4.5-fold its systemic clearance — first-pass extraction quantified in humans
Study: Human pharmacokinetic study (intravenous and oral probe-drug clearances), Clin Pharmacol Ther 2007
Population: 99 healthy volunteers (58 men, 41 women) genotyped for CYP3A5, given intravenous then oral midazolam and alfentanil (CYP3A probe drugs) on successive days, with plasma concentrations by mass spectrometry and pupil diameter as the pharmacodynamic readout.
Summary: Kharasch 2007: in 99 healthy volunteers, apparent oral clearance of midazolam ran about 4.5-fold its systemic clearance — first-pass extraction quantified in humans
Result: Systemic clearances were about 7.8 mL/kg/min for midazolam and 4.6 mL/kg/min for alfentanil (in the common CYP3A5*3/*3 genotype), while apparent oral clearances were about 35.2 and 11.8 mL/kg/min respectively — the several-fold gap between oral and systemic clearance is the first-pass effect expressed as a number: most of an oral dose of a well-extracted CYP3A substrate is cleared before or during its first circuit. The record reports consistent concordance between the two probes in clearances and extraction ratios, and no CYP3A5 genotype effect on systemic or oral clearance despite the genotype's effect in liver microsomes.
Watch out: Midazolam and alfentanil are intermediate-extraction probes and part of their first pass is intestinal as well as hepatic CYP3A; the oral-to-systemic clearance ratio therefore measures combined gut-plus-liver first pass, not the hepatic extraction ratio in isolation.
Source: Kharasch ED et al. Influence of CYP3A5 genotype on the pharmacokinetics and pharmacodynamics of the cytochrome P4503A probes alfentanil and midazolam. Clinical pharmacology and therapeutics. 2007. PMID: 17554244. Registry ID: none in the record. MeSH: Administration, Oral · Adult · Black or African American/genetics · Alfentanil/administration & dosage,adverse effects,blood,pharmacokinetics · Biomarkers/metabolism · Cytochrome P-450 CYP3A · Cytochrome P-450 Enzyme System/genetics,metabolism · Female · Gene Frequency · Genotype · Hispanic or Latino/genetics · Humans · Injections, Intravenous · Male · Midazolam/administration & dosage,blood,pharmacokinetics · Middle Aged · Miosis/chemically induced · Phenotype · Polymorphism, Genetic · Pupil/drug effects · Reference Values · Substrate Specificity · White People/genetics
Card 3 — Wilson 1976: propranolol and propoxyphene in children showed the high-extraction pattern — a large presystemic (first-pass) effect and marked interindividual variability
Study: Human pharmacokinetic study (sparse-sampling disposition study in children), Clin Pharmacol Ther 1976
Population: Children given single oral doses of propoxyphene, and children on chronic oral propranolol as tablets or solution, studied with sparse-sampling protocols designed to minimise blood draws; plasma concentration data pooled across children to construct disposition curves. The record does not print a single total N for the propranolol arm, so N is not documented on this card.
Summary: Wilson 1976: propranolol and propoxyphene in children showed the high-extraction pattern — a large presystemic (first-pass) effect and marked interindividual variability
Result: Propoxyphene's average half-life in children was 3.5 hours. No clear bioavailability difference appeared between propranolol tablets and solution at the end of a dosing interval during chronic oral administration. Both drugs showed marked interindividual differences in plasma concentrations after oral dosing — findings the authors state are consistent with the high hepatic extraction ratio and large presystemic (first-pass) effect previously described in adults, and which led them to support plasma-level monitoring.
Watch out: A 1976 sparse-sampling design in children: it documents the high-extraction pattern qualitatively (variability, first pass) rather than measuring an extraction ratio, and propoxyphene is no longer a drug in clinical use — the card stands for the physiology, not the agents.
Source: Wilson JT et al. Disposition of propoxyphene and propranolol in children. Clinical pharmacology and therapeutics. 1976. PMID: 1261164. Registry ID: none in the record. MeSH: Adolescent · Age Factors · Biological Availability · Body Weight · Child · Child, Preschool · Dextropropoxyphene/analogs & derivatives,metabolism · Half-Life · Humans · Infant · Propranolol/metabolism
Card 4 — Synthesis: one equation, two regimes — clearance equals flow times extraction, so flow governs high-extraction drugs and enzyme capacity governs low-extraction ones, and oral dosing exposes the difference as first pass
Study: Synthesis
Population: Synthesis of the three carded human studies (Pomier-Layrargues 1986; Kharasch 2007; Wilson 1976), framed by Guyton & Hall and Boron & Boulpaep as textbook accounts.
Summary: Synthesis: one equation, two regimes — clearance equals flow times extraction, so flow governs high-extraction drugs and enzyme capacity governs low-extraction ones, and oral dosing exposes the difference as first pass
Result: The human evidence lines up with the textbook model at every testable point. Cut flow and bypass the liver, and high-extraction clearance falls in proportion while intrinsic clearance and the low-extraction probe do not move (Pomier-Layrargues). Give a well-extracted drug by mouth to healthy people and its apparent clearance multiplies several-fold over its systemic clearance — the arithmetic of bioavailability near 1 − E (Kharasch). Choose the classic high-extraction drug propranolol and the signature is large first pass with wide between-person variability, present already in children (Wilson). Practical consequences the physiology dictates: dose changes in liver disease cannot be read off one rule — flow, shunting and severity move high-extraction drugs, enzyme capacity and binding move low-extraction drugs, and the same cirrhotic liver can leave one drug's clearance untouched while halving another's.
Watch out: Direct hepatic-vein catheter measurement of extraction ratios across a drug panel in healthy humans is ethically constrained and largely historical; the modern human record demonstrates the model's consequences (flow changes, oral–systemic gaps) rather than tabulating E drug by drug, and the synthesis keeps that distinction.
Source: Synthesis of Pomier-Layrargues G et al., Gastroenterology 1986 (PMID: 3710065); Kharasch ED et al., Clin Pharmacol Ther 2007 (PMID: 17554244); Wilson JT et al., Clin Pharmacol Ther 1976 (PMID: 1261164). Registry IDs as on the individual cards.