SourceMed · Shelf #6427 in the ask interface
DMEK versus DSAEK/DSEK for corneal endothelial failure (DETECT): 1.8 lines better acuity at 6 months and 1.4 lines at 12 months, with more rebubbling as the trade
Shelf #6427 · Eyes, skin, nose & allergy
POSSIBLE (benefit) — one small randomised trial (DETECT, 38 patients) plus concordant observational syntheses: DMEK gave 1.5-1.8 lines better acuity than ultrathin DSAEK over the first year with similar complications, at the cost of more rebubbling; the small randomised base caps the stamp at POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2018–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with corneal endothelial failure, does Descemet membrane endothelial keratoplasty (DMEK) give faster and better visual recovery than Descemet stripping automated endothelial keratoplasty (DSAEK/DSEK)? (DETECT.)
Balance of the evidence
POSSIBLE (benefit) — one small randomised trial plus concordant observational syntheses. The DETECT randomised trial (Chamberlain 2019, PMID: 29945801) found Descemet membrane endothelial keratoplasty (DMEK) gave 1.5 lines better best spectacle-corrected visual acuity at 3 months, 1.8 lines at 6 months and 1.4 lines at 12 months than ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK), with similar complication rates and endothelial cell counts. The meta-analysis of retrospective comparisons found the same direction — 12-month acuity 0.16 versus 0.30 logMAR, fewer rejections with DMEK but more rebubbling (Marques 2019, PMID: 29661044) — and the Cochrane review, written before DETECT, found low-certainty evidence of better acuity with DMEK at the cost of more graft dislocations (Stuart 2018, PMID: 29940078). POSSIBLE (benefit): DETECT randomised only 38 patients, and the supporting base is retrospective, so the stamp stays at POSSIBLE despite concordance.
MeSH: ['Corneal Transplantation', 'Descemet Membrane', 'Descemet Stripping Endothelial Keratoplasty', "Fuchs' Endothelial Dystrophy", 'Humans', 'Visual Acuity']
Cards (4)
Card 1 — Chamberlain 2019 (DETECT RCT, 50 eyes of 38 patients): DMEK gave 1.8 lines better acuity than ultrathin DSAEK at 6 months (P<0.001), 1.5 lines at 3 months and 1.4 lines at 12 months; complications similar
Study: Randomised controlled trial (DETECT, Chamberlain 2019)
Population: 50 eyes of 38 patients with corneal endothelial dysfunction from Fuchs endothelial dystrophy or pseudophakic bullous keratopathy, considered good candidates for either operation, randomised by the eye bank to ultrathin DSAEK (UT-DSAEK) or DMEK 1-2 days before surgery by two surgeons at two US centres; patients and outcome assessors were masked.
Summary: Chamberlain 2019 (DETECT RCT, 50 eyes of 38 patients): DMEK gave 1.8 lines better acuity than ultrathin DSAEK at 6 months (P<0.001), 1.5 lines at 3 months and 1.4 lines at 12 months; complications similar
Result: After correcting for baseline acuity, DMEK gave better best spectacle-corrected visual acuity than UT-DSAEK by 1.5 lines at 3 months (95% CI 0.6-2.5 lines better; P=0.002), 1.8 lines at 6 months (95% CI 1.0-2.8; P<0.001, the primary outcome) and 1.4 lines at 12 months (95% CI 0.7-2.2; P<0.001). Mean endothelial cell counts were 1963 versus 2113 cells/mm² at 6 months (P=0.17) and 1855 versus 2070 cells/mm² at 12 months (P=0.051). Intraoperative and postoperative complication rates were similar between groups.
Watch out: Only 38 patients at two expert centres, and the comparator was ultrathin DSAEK — the best version of the older operation. Results from two experienced DMEK surgeons may not transfer to a surgeon's early DMEK learning curve.
Source: Chamberlain W et al. Descemet Endothelial Thickness Comparison Trial: A Randomized Trial Comparing Ultrathin Descemet Stripping Automated Endothelial Keratoplasty with Descemet Membrane Endothelial Keratoplasty. Ophthalmology. 2019. PMID: 29945801. Registry ID: NCT02373137. MeSH: Aged; Aged, 80 and over; Cell Count; Corneal Dystrophies, Hereditary; Corneal Pachymetry; Descemet Membrane; Descemet Stripping Endothelial Keratoplasty; Double-Blind Method; Female; Follow-Up Studies; Fuchs' Endothelial Dystrophy; Humans; Male; Middle Aged; Visual Acuity
Card 2 — Marques 2019 (meta-analysis, 10 retrospective studies, 947 eyes): acuity better with DMEK at every time point (0.16 versus 0.30 logMAR at 12 months); rejection 60% relatively lower, rebubbling more frequent (RR 2.48)
Study: Meta-analysis of retrospective comparative studies (Marques 2019) — observational base
Population: 947 eyes with Fuchs endothelial dystrophy in 10 retrospective comparative studies of DMEK (646 eyes) versus DSAEK, searched to August 2017.
Summary: Marques 2019 (meta-analysis, 10 retrospective studies, 947 eyes): acuity better with DMEK at every time point (0.16 versus 0.30 logMAR at 12 months); rejection 60% relatively lower, rebubbling more frequent (RR 2.48)
Result: Best-corrected visual acuity was better with DMEK at 3, 6 and 12 months (0.16 logMAR with DMEK versus 0.30 logMAR with DSAEK at 12 months; p<0.001). DMEK had a 60% lower rejection rate in relative terms (risk ratio 0.4, 95% CI 0.24-0.67; p=0.0005) but required more rebubbling (risk ratio 2.48, 95% CI 1.32-4.64; p=0.005). Primary graft failure and endothelial cell density loss did not differ significantly. Patient satisfaction was higher after DMEK (odds ratio 10.29, 95% CI 3.55-29.80).
Watch out: All ten studies were retrospective and of moderate methodological quality, in Fuchs dystrophy only; surgeon selection of easier eyes for DMEK can inflate its advantage. The rejection figure is a relative measure; the record gives no absolute rates beside it.
Source: Marques RE et al. DMEK versus DSAEK for Fuchs' endothelial dystrophy: A meta-analysis. European Journal of Ophthalmology. 2019. PMID: 29661044. Registry ID: none in the record. MeSH: Adult; Aged; Cell Count; Descemet Membrane; Descemet Stripping Endothelial Keratoplasty; Endothelium, Corneal; Female; Fuchs' Endothelial Dystrophy; Humans; Male; Middle Aged; Odds Ratio; Patient Satisfaction; Postoperative Period; Retrospective Studies; Visual Acuity
Card 3 — Stuart 2018 (Cochrane review, 4 non-randomised paired-eye studies, 144 eyes): low-certainty evidence of better 1-year acuity with DMEK (mean difference -0.14 logMAR), with more graft dislocations (RR 5.40)
Study: Cochrane systematic review of non-randomised studies (Stuart 2018)
Population: 72 participants (144 eyes) with Fuchs endothelial dystrophy and endothelial failure in four non-randomised contralateral-eye studies in which DSAEK was performed in the first eye and DMEK in the fellow eye; the review (search to August 2017) found no randomised trials at that date.
Summary: Stuart 2018 (Cochrane review, 4 non-randomised paired-eye studies, 144 eyes): low-certainty evidence of better 1-year acuity with DMEK (mean difference -0.14 logMAR), with more graft dislocations (RR 5.40)
Result: At one year, DMEK may give better best-corrected visual acuity than DSAEK (mean difference -0.14 logMAR, 95% CI -0.18 to -0.10; 4 studies, 140 eyes; low-certainty evidence). No participant had severe visual loss. Endothelial cell count data were inconclusive. No primary graft failure and only one graft rejection were recorded across 144 eyes. Graft dislocation was more common with DMEK (risk ratio 5.40, 95% CI 1.51-19.3; very low-certainty evidence), recorded in one or two per 100 DSAEK participants and more often with DMEK.
Watch out: Pre-DETECT and rated high risk of bias: DSAEK always preceded DMEK in the same patients, so era and learning effects run through every comparison. Its dislocation signal is the caution the randomised trial was too small to settle.
Source: Stuart AJ et al. Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure. Cochrane Database of Systematic Reviews. 2018. PMID: 29940078. Registry ID: none in the record. MeSH: Adult; Cell Count; Corneal Diseases; Corneal Transplantation; Descemet Membrane; Descemet Stripping Endothelial Keratoplasty; Endothelial Cells; Fuchs' Endothelial Dystrophy; Humans; Non-Randomized Controlled Trials as Topic; Postoperative Complications; Visual Acuity
Card 4 — Synthesis: DMEK recovers vision faster and to a better level than DSAEK/DSEK — about 1.5-1.8 lines in the one randomised trial — at the cost of more rebubbling/dislocation; POSSIBLE on a small randomised base
Study: Synthesis
Population: Synthesis of the three cards above: one randomised trial (50 eyes of 38 patients), one meta-analysis of 10 retrospective studies (947 eyes) and one Cochrane review of 4 paired-eye studies (144 eyes).
Summary: Synthesis: DMEK recovers vision faster and to a better level than DSAEK/DSEK — about 1.5-1.8 lines in the one randomised trial — at the cost of more rebubbling/dislocation; POSSIBLE on a small randomised base
Result: All three sources agree on direction: better and faster acuity with DMEK, no clear endothelial-cell penalty, fewer rejections, and a consistent counter-signal of more graft dislocation/rebubbling with DMEK. The randomised evidence is a single 38-patient trial, so the benefit stamp is POSSIBLE; the rebubbling cost is the part of the trade a patient should hear before choosing.
Watch out: DETECT compared DMEK with ultrathin DSAEK specifically; older standard-thickness DSAEK/DSEK would likely fare worse, so this shelf's gap is a conservative estimate of the DMEK advantage.
Source: Synthesis of Chamberlain W et al. Ophthalmology. 2019. PMID: 29945801; Marques RE et al. European Journal of Ophthalmology. 2019. PMID: 29661044; Stuart AJ et al. Cochrane Database of Systematic Reviews. 2018. PMID: 29940078. Registry IDs as on the cards above.