SourceMed · Shelf #6445 in the ask interface

Starling forces in humans (physiology): interstitial pressure is slightly negative, plasma colloid osmotic pressure ~24–26 mmHg and interstitial COP roughly 6–13 mmHg, so net filtration is small — and when filtration rises, falling interstitial COP (washdown) is the measured buffer; Guyton's ~17 mmHg total safety-factor budget is the textbook's account

Shelf #6445 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1983–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, what are the Starling forces across capillaries — interstitial fluid pressure and colloid osmotic pressures — and how large are the safety factors against oedema?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Textbook framing (Guyton & Hall Textbook of Medical Physiology): capillary exchange is set by four forces — capillary pressure pushing out, interstitial pressure (slightly negative, ~−3 mmHg in the textbook's account) pushing in, plasma colloid osmotic pressure (~28 mmHg in the textbook) pulling in, and interstitial colloid osmotic pressure pulling out — leaving a small net filtration that lymph returns; against oedema the textbook budgets ~17 mmHg of safety factors (negative interstitial pressure ~3 mmHg, increased lymph flow ~7 mmHg, interstitial protein washdown ~7 mmHg). The carded human wick studies measure the same system at slightly lower absolute values: interstitial pressure −0.8 mmHg in healthy ankle tissue (Stranden & Myhre 1983), plasma COP 23.2 mmHg in early pregnancy and 25.6 mmHg in healthy children (Øian 1985; Guthe 2015), interstitial COP 9.2 mmHg at the ankle and up to 13.1 mmHg on the thorax. The washdown factor is not just textbook arithmetic — in pregnancy interstitial COP fell further than plasma COP as filtration rose (Øian), and when bypass dilution reversed the COP gradient, interstitial pressure rose measurably until the gradient recovered (Rein 1988). The lymph-flow limb of the safety budget and the ~17 mmHg total are presented as the textbook's account: no carded record here measures human lymph flow or prints that budget.

MeSH: Adult · Aged · Arteriosclerosis/physiopathology · Blood Pressure · Capillary Permeability · Catheterization · Extracellular Space · Female · Humans · Hydrostatic Pressure · Male · Middle Aged · Osmotic Pressure · Pregnancy · Regional Blood Flow

Cards (5)

Card 1 — Stranden & Myhre 1983: in 20 healthy controls, ankle interstitial pressure was slightly negative (−0.8 mmHg) and interstitial colloid osmotic pressure 9.2 mmHg — the resting Starling balance measured by wicks

Study: Human physiological study (wick and wick-in-needle Starling-force measurements), Scand J Clin Lab Invest 1983

Population: 20 healthy controls and 27 patients with lower-limb atherosclerosis; subcutaneous tissue at the ankle; interstitial fluid collected by implanted nylon wicks and interstitial fluid pressure (Pif) measured by the wick-in-needle technique.

Summary: Stranden & Myhre 1983: in 20 healthy controls, ankle interstitial pressure was slightly negative (−0.8 mmHg) and interstitial colloid osmotic pressure 9.2 mmHg — the resting Starling balance measured by wicks

Result: Mean Pif in controls was −0.8 mmHg (patients −1.0 mmHg) — subatmospheric, as the Guyton account requires. Interstitial colloid osmotic pressure (COPif) was 9.2 mmHg in controls versus 5.9 mmHg in atherosclerosis. The calculated reabsorption pressure (the capillary pressure at which filtration balances) was 15.8 mmHg in controls and 18.3 mmHg in patients. In seven patients with arterial emboli Pif was much lower (mean −4.5 mmHg).

Watch out: Healthy-control values come from one ankle site in one laboratory tradition (the Aukland school); interstitial pressure and COPif vary by tissue and site, and the atherosclerosis comparison group is a disease group, not part of the normal reference.

Source: Stranden E et al. Transcapillary forces in patients with lower limb ischemia. Scandinavian journal of clinical and laboratory investigation. 1983. PMID: 6622969. Registry ID: none in the record (pre-registration era). MeSH: Adolescent · Adult · Aged · Arteriosclerosis/physiopathology · Blood Pressure · *Capillary Permeability · Catheterization · Embolism/complications · Extracellular Space/analysis · Female · Humans · Ischemia/etiology,physiopathology · Leg/blood supply · Male · Methods · Middle Aged · Osmotic Pressure · Regional Blood Flow · Transducers, Pressure

Card 2 — Øian 1985: in normal pregnancy the interstitial colloid osmotic pressure fell further than plasma COP (thorax 13.1→8.4 mmHg) — the washdown safety factor working in humans

Study: Human physiological study (wick COP and wick-in-needle pressure in pregnancy), Br J Obstet Gynaecol 1985

Population: 10 normal pregnant women in the first trimester and 10 in the third trimester; interstitial fluid collected by implanted subcutaneous wicks (thorax and ankle), interstitial pressure by wick-in-needle, plasma colloid osmotic pressure (COPp) from blood.

Summary: Øian 1985: in normal pregnancy the interstitial colloid osmotic pressure fell further than plasma COP (thorax 13.1→8.4 mmHg) — the washdown safety factor working in humans

Result: COPp fell from 23.2 mmHg (first trimester) to 21.1 mmHg (third trimester). COPi fell more: from 13.1 to 8.4 mmHg on the thorax and from 9.6 to 5.5 mmHg at the ankle, with only small changes in interstitial pressure. The authors' reading: the larger fall in COPi than in COPp opposes the increased filtration of pregnancy and prevents a rise in interstitial volume — the protein-washdown safety factor, measured — at the price of a reduced safety margin against oedema in late pregnancy.

Watch out: Cross-sectional (different women in each trimester), not longitudinal; pregnancy is a high-filtration state, so the absolute COP values are pregnancy values, while the direction of the COPi fall is the generalisable safety-factor finding.

Source: Øian P et al. Oedema-preventing mechanisms in subcutaneous tissue of normal pregnant women. British journal of obstetrics and gynaecology. 1985. PMID: 4063227. Registry ID: none in the record (pre-registration era). MeSH: Adult · Blood Proteins/analysis · Capillary Permeability · Edema/etiology · Extracellular Space/physiology · Female · Humans · Hydrostatic Pressure · Methods · Osmotic Pressure · *Pregnancy · Pregnancy Trimester, First · Pregnancy Trimester, Third

Card 3 — Guthe 2015: in 99 healthy children, mean plasma colloid osmotic pressure was 25.6 mmHg — the modern reference value for the plasma side of the Starling balance

Study: Human physiological study (plasma and wick interstitial COP reference values), PLoS One 2015

Population: 99 healthy children aged 2–10 years; nylon wicks implanted subcutaneously in arm and leg during sedation for minor surgery; COP of plasma and wick (interstitial) fluid measured in a colloid osmometer built for small samples.

Summary: Guthe 2015: in 99 healthy children, mean plasma colloid osmotic pressure was 25.6 mmHg — the modern reference value for the plasma side of the Starling balance

Result: Mean plasma COP was 25.6 ± 3.3 mmHg. Plasma and interstitial COP did not differ by sex, arm versus leg site, or (under 8 years) by age; children aged 8–10 years had significantly higher COP in both plasma and interstitial fluid. Prolonged wick implantation did not change interstitial COP, and gravity had no significant effect on it. The authors note child values are comparable to adults.

Watch out: Children, not adults, and wicks were placed during anaesthesia for minor surgery; the abstract prints the plasma mean but not a single interstitial mean value, so no interstitial number is claimed from this record.

Source: Guthe HJ et al. Interstitial fluid colloid osmotic pressure in healthy children. PloS one. 2015. PMID: 25853713. Registry ID: ClinicalTrials.gov NCT01044641. MeSH: Adult · Child · Child, Preschool · Colloids · Extracellular Fluid/physiology · Extracellular Space/physiology · Female · Humans · Male · Osmotic Pressure/physiology · Plasma/physiology · Specimen Handling/methods

Card 4 — Rein 1988: during extracorporeal circulation the transcapillary COP gradient reversed (interstitial COP exceeded plasma COP) and interstitial pressure rose — the safety factors overwhelmed, in real time

Study: Human physiological study (serial Starling forces around cardiac surgery), Cardiovasc Drugs Ther 1988

Population: 13 patients undergoing coronary surgery with extracorporeal circulation (ECC); COP of interstitial fluid by wick and by suction-blister, interstitial pressure by wick-in-needle, plasma COP from cubital venous blood, before, during and for 24 h after ECC.

Summary: Rein 1988: during extracorporeal circulation the transcapillary COP gradient reversed (interstitial COP exceeded plasma COP) and interstitial pressure rose — the safety factors overwhelmed, in real time

Result: Plasma COP fell by about 50% during ECC and recovered within 6 h. Interstitial COP was higher than plasma COP during ECC and reached its minimum 4–5 h postoperatively; the normal gradient direction (plasma > interstitial) was restored after ECC but the pre-ECC interstitial level was not regained within 24 h. Interstitial pressure rose during ECC and for 2–3 h afterwards, returning to baseline within 24 h — a measured episode of net filtration predisposing to interstitial oedema until several hours after surgery.

Watch out: A surgical/dilutional stress, not resting physiology — carded to show the forces moving and the safety margin being consumed, not as normal values; N = 13.

Source: Rein KA et al. Time-related changes in the Starling forces following extracorporeal circulation. Cardiovascular drugs and therapy. 1988. PMID: 3154633. Registry ID: none in the record (pre-registration era). MeSH: Adult · Aged · Blood Viscosity/physiology · *Extracorporeal Circulation · Female · Humans · Middle Aged · Time Factors

Card 5 — Synthesis: the human wick measurements match the Guyton Starling picture — near-zero/negative interstitial pressure, plasma COP ~24–26 mmHg, interstitial COP roughly 6–13 mmHg — and the safety factors are the textbook's arithmetic on top of them

Study: Synthesis

Population: Synthesis of the four carded human studies above (Stranden & Myhre 1983; Øian 1985; Guthe 2015; Rein 1988), framed by Guyton & Hall Textbook of Medical Physiology as textbook framing.

Summary: Synthesis: the human wick measurements match the Guyton Starling picture — near-zero/negative interstitial pressure, plasma COP ~24–26 mmHg, interstitial COP roughly 6–13 mmHg — and the safety factors are the textbook's arithmetic on top of them

Result: The measured forces agree across four decades of wick studies: interstitial pressure sits at or just below atmospheric (−0.8 mmHg in healthy ankle tissue), plasma COP is ~23–26 mmHg, and interstitial COP is substantial (about 9 mmHg at the ankle, 10–13 mmHg at the thorax in early pregnancy) — so the net filtration pressure at the capillary is small, not the large gradient a plasma-only view would suggest. The washdown safety factor is directly visible: when filtration rose in pregnancy, interstitial COP fell further than plasma COP, buffering volume (Øian); when the gradient was forcibly reversed by bypass dilution, interstitial pressure rose and oedema threatened until the gradient recovered (Rein). Guyton's quantitative safety-factor budget — roughly 3 mmHg from negative interstitial pressure, ~7 mmHg from increased lymph flow and ~7 mmHg from interstitial protein washdown, ~17 mmHg in total — is presented as the textbook's account: no carded human record prints that budget, and the lymph-flow limb in particular rests on the textbook synthesis of animal and human lymph work rather than on a carded human measurement here.

Watch out: No carded record measures human lymph flow directly, so the lymph safety factor is carried as textbook framing only; capillary pressure itself is inferred (reabsorption pressure), never measured directly in these human studies.

Source: Synthesis of the cards on this shelf (PMIDs 6622969, 4063227, 25853713, 3154633), framed by Guyton & Hall Textbook of Medical Physiology. No additional source.