SourceMed · Shelf #6451 in the ask interface

Coronary flow reserve in healthy humans (physiology): flow can rise about fourfold above rest — 4.6 ± 0.9 by adenosine PET and 4.0–4.5 by transthoracic Doppler velocity reserve — measured non-invasively with PET tracers or bedside LAD Doppler during vasodilator infusion

Shelf #6451 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1992–2005.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, how much can coronary blood flow rise above rest (coronary flow reserve), and how is it measured non-invasively?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Textbook framing (Guyton & Hall): resting coronary flow is tightly autoregulated, and the circulation holds a large vasodilator reserve in hand. Adjacency, stated plainly: pack #6304 already homes coronary autoregulation — the pressure range over which flow is held constant and its adenosine/K-ATP mediators — and deliberately excluded reserve magnitude; none of its PMIDs is re-carded here, and this shelf asks only how large the reserve is in healthy humans and how it is measured without a catheter. The measurements converge across methods: by ¹³N-ammonia PET during adenosine, healthy young adults show a flow reserve of 4.6 ± 0.9 (hyperaemic flow 340 ± 57 mL/100 g/min; Muzik 1996, N = 10), and dipyridamole PET gives healthy hyperaemic flow of 3.71 ± 0.86 mL/min/g (Parodi 1992, N = 13). By transthoracic Doppler of the LAD during ATP infusion — fully non-invasive — healthy velocity reserve is 4.02 ± 0.70 (Yamashita 2005, N = 11) and 4.5 ± 0.9 (Hirata 2004, N = 10). The honest summary is a range, ~4- to 4.6-fold, not a single canonical number.

MeSH: Adult · Adenosine/pharmacology · Blood Flow Velocity · Coronary Circulation · Echocardiography, Doppler · Female · Humans · Male · Tomography, Emission-Computed · Vascular Resistance · Vasodilator Agents/pharmacology

Cards (5)

Card 1 — Muzik 1996: by ¹³N-ammonia PET with adenosine, healthy young adults had a myocardial flow reserve of 4.6 ± 0.9 — hyperaemic flow 340 ± 57 vs rate-pressure-corrected rest flow 77 ± 16 mL/100 g/min

Study: Human physiological study (quantitative PET myocardial flow reserve, healthy controls), J Am Coll Cardiol 1996

Population: 10 healthy young adult volunteers (the control arm of a Kawasaki-disease study) and 10 children with prior Kawasaki disease, studied with nitrogen-13 ammonia PET at rest and during adenosine stress; rest flows normalised to the rate-pressure product.

Summary: Muzik 1996: by ¹³N-ammonia PET with adenosine, healthy young adults had a myocardial flow reserve of 4.6 ± 0.9 — hyperaemic flow 340 ± 57 vs rate-pressure-corrected rest flow 77 ± 16 mL/100 g/min

Result: In healthy volunteers, hyperaemic myocardial blood flow was 340 ± 57 mL/100 g/min against a corrected rest flow of 77 ± 16 mL/100 g/min, giving a myocardial flow reserve of 4.6 ± 0.9. (The Kawasaki children, by contrast, reached only 263 ± 64 with a reserve of 3.2 ± 0.7 — the disease comparison that makes the healthy value a reference.) Quantitative PET showed no regional perfusion abnormalities in either group.

Watch out: The healthy arm is young adults serving as controls in a paediatric-disease study (N = 10); rest flow is rate-pressure-product-corrected, so the reserve ratio is a corrected ratio, as the record presents it.

Source: Muzik O et al. Quantification of myocardial blood flow and flow reserve in children with a history of Kawasaki disease and normal coronary arteries using positron emission tomography. Journal of the American College of Cardiology. 1996. PMID: 8772768. Registry ID: none in the record (pre-registration era). MeSH: Adenosine/pharmacology · Adolescent · Adult · Child · *Coronary Circulation/drug effects · Coronary Vessels/pathology · Female · Humans · Male · Mucocutaneous Lymph Node Syndrome/diagnostic imaging,pathology,physiopathology · *Tomography, Emission-Computed · Vascular Resistance · Vasodilator Agents/pharmacology

Card 2 — Parodi 1992: by dynamic PET, healthy subjects reached 3.71 ± 0.86 mL/min/g after dipyridamole (and 2.15 ± 0.73 during atrial pacing) — against 2.35 in hypertensive patients on the same protocol

Study: Human physiological study (dynamic PET flow reserve, healthy controls), Drugs 1992

Population: 13 healthy subjects and 27 patients with essential hypertension and normal coronary arteries, studied by dynamic PET at rest, during atrial pacing and after dipyridamole infusion.

Summary: Parodi 1992: by dynamic PET, healthy subjects reached 3.71 ± 0.86 mL/min/g after dipyridamole (and 2.15 ± 0.73 during atrial pacing) — against 2.35 in hypertensive patients on the same protocol

Result: Healthy myocardial blood flow rose to 2.15 ± 0.73 mL/min/g during atrial pacing and 3.71 ± 0.86 mL/min/g after dipyridamole. Hypertensive patients started at 0.97 ± 0.25 mL/min/g at rest and reached only 1.60 ± 0.38 (pacing) and 2.35 ± 0.95 (dipyridamole) — both significantly below the healthy hyperaemic values. The record prints the healthy hyperaemic flows rather than a healthy rest flow or ratio, so this card claims the hyperaemic ceiling, not a reserve ratio.

Watch out: A hypertension study's control arm (N = 13); dipyridamole and adenosine are related but not identical vasodilator stimuli, and pacing raises flow by demand rather than by vasodilation — three different routes to 'reserve' on one card, kept distinct in the text.

Source: Parodi O et al. Regional myocardial blood flow and coronary reserve in hypertensive patients. The effect of therapy. Drugs. 1992. PMID: 1283584. Registry ID: none in the record (pre-registration era). MeSH: Adult · Coronary Circulation/drug effects · Enalapril/administration & dosage,pharmacology · Female · Hemodynamics/drug effects · Humans · Hypertension/drug therapy,physiopathology · Male · Middle Aged · Regional Blood Flow/drug effects · Verapamil/administration & dosage,pharmacology

Card 3 — Yamashita 2005: by transthoracic Doppler echocardiography of the LAD with ATP infusion, coronary flow velocity reserve in 11 healthy young men was 4.02 ± 0.70 — a fully non-invasive bedside measurement

Study: Human physiological study (transthoracic Doppler coronary flow velocity reserve), Int J Cardiol 2005

Population: 11 healthy male volunteers (aged 23.3 ± 0.9 years) studied on three days (placebo, oral methionine, methionine + vitamin C) with coronary flow velocity reserve measured by transthoracic Doppler echocardiography of the left anterior descending artery during intravenous adenosine-triphosphate infusion; the placebo-day value is the normal reference. N = 11.

Summary: Yamashita 2005: by transthoracic Doppler echocardiography of the LAD with ATP infusion, coronary flow velocity reserve in 11 healthy young men was 4.02 ± 0.70 — a fully non-invasive bedside measurement

Result: On the control condition, hyperaemic average diastolic peak velocity and coronary flow velocity reserve were 87.2 ± 11.4 cm/s and 4.02 ± 0.70. Acute methionine loading (homocysteine 12.9 → 32.1 nmol/mL) cut reserve to 3.35 ± 0.52, and vitamin C co-administration prevented the fall — the study's oxidative-stress point. For this shelf the card carries the method and the healthy reserve: ~4.0 by bedside Doppler, concordant with PET.

Watch out: Velocity reserve in one vessel (LAD), not absolute flow — velocity reserve equals flow reserve only if epicardial diameter is unchanged during hyperaemia; young men only.

Source: Yamashita K et al. Experimental hyperhomocysteinemia impairs coronary flow velocity reserve. International journal of cardiology. 2005. PMID: 16168809. Registry ID: none in the record. MeSH: Adenosine Triphosphate/administration & dosage · Administration, Oral · Adult · Antioxidants/administration & dosage · Ascorbic Acid/administration & dosage · Biomarkers/blood · Blood Flow Velocity · *Coronary Circulation · Endothelium, Vascular/drug effects,metabolism · Homocysteine/blood,drug effects,metabolism · Humans · Hyperhomocysteinemia/metabolism,physiopathology · Male · Methionine/administration & dosage · Oxidative Stress/drug effects · Reference Values · Research Design · Superoxide Dismutase/drug effects,metabolism · Time Factors

Card 4 — Hirata 2004: in 10 healthy men, baseline coronary flow velocity reserve by transthoracic Doppler was 4.5 ± 0.9 — and black tea raised it to 5.2 ± 0.9 within hours

Study: Human physiological study (Doppler flow velocity reserve, tea vs caffeine crossover), Am J Cardiol 2004

Population: 10 healthy male volunteers in a double-blind crossover comparison of black tea versus caffeine, with left-anterior-descending coronary flow velocity measured at baseline and during adenosine-triphosphate hyperaemia by transthoracic Doppler echocardiography, before and after each beverage. N = 10.

Summary: Hirata 2004: in 10 healthy men, baseline coronary flow velocity reserve by transthoracic Doppler was 4.5 ± 0.9 — and black tea raised it to 5.2 ± 0.9 within hours

Result: Before beverage consumption, coronary flow velocity reserve was 4.5 ± 0.9. After black tea it rose to 5.2 ± 0.9 (p < 0.0001); the reserve ratio (after ÷ before) was 1.18 ± 0.07 for tea versus 1.04 ± 0.08 for caffeine. The card's physiology content is the second independent healthy Doppler reference (~4.5) and the demonstration that reserve is acutely modifiable by a dietary vasodilator exposure — reserve is a state, not a fixed anatomical constant.

Watch out: N = 10 healthy men; the tea effect is an acute pharmacological observation from a small crossover, carded for its baseline reserve value and the modifiability point, not as a dietary recommendation.

Source: Hirata K et al. Black tea increases coronary flow velocity reserve in healthy male subjects. The American journal of cardiology. 2004. PMID: 15165919. Registry ID: none in the record. MeSH: Adult · *Blood Flow Velocity/physiology · Caffeine/pharmacology · *Coronary Circulation/physiology · Cross-Over Studies · Double-Blind Method · Echocardiography · Echocardiography, Doppler, Color · Flavonoids · Humans · Male · *Tea

Card 5 — Synthesis: healthy coronary flow reserve is about 4- to 4.6-fold by PET and about 4.0–4.5 by bedside Doppler — measurable entirely non-invasively, and distinct from the autoregulation shelf (pack #6304)

Study: Synthesis

Population: Synthesis of the four carded human studies above (Muzik 1996; Parodi 1992; Yamashita 2005; Hirata 2004), framed by Guyton & Hall's coronary-circulation account as textbook framing. Coronary autoregulation and its mediators are homed on pack #6304 and none of its studies is re-carded here.

Summary: Synthesis: healthy coronary flow reserve is about 4- to 4.6-fold by PET and about 4.0–4.5 by bedside Doppler — measurable entirely non-invasively, and distinct from the autoregulation shelf (pack #6304)

Result: Two independent measurement families converge: quantitative PET gives a healthy reserve of 4.6 ± 0.9 (Muzik, adenosine, ¹³N-ammonia) with hyperaemic flow ~3.4 mL/min/g, and 3.71 ± 0.86 mL/min/g after dipyridamole (Parodi); transthoracic Doppler velocity reserve gives 4.02 ± 0.70 (Yamashita) and 4.5 ± 0.9 (Hirata) in healthy young men. So the healthy coronary circulation can raise flow roughly fourfold-plus above rest — the reserve that autoregulation (pack #6304) spends to hold resting flow constant as pressure falls. Measurement is now routinely non-invasive: PET with ¹³N-ammonia or ¹⁵O-water gives absolute flow in mL/min/g; Doppler echocardiography gives a velocity ratio in the LAD at the bedside; cardiovascular MRI perfusion is the third route named in the textbooks, though no carded record on this shelf uses it, so it is named as a method, not evidenced here. Reserve is also a state variable — acutely lowered by a methionine load and raised by black tea in these small studies — not a fixed property of the vessel.

Watch out: Healthy arms are small (N = 10–13) and mostly young men; vasodilator (adenosine/ATP/dipyridamole), tracer and correction methods differ between studies, so the honest claim is the convergent range (~4–4.6), not a single canonical number.

Source: Synthesis of the cards on this shelf (PMIDs 8772768, 1283584, 16168809, 15165919), framed by Guyton & Hall Textbook of Medical Physiology. Autoregulation is homed on pack #6304 and deliberately not re-carded. No additional source.