SourceMed · Shelf #6484 in the ask interface

Late-night salivary cortisol for Cushing's: pooled sensitivity 95.8% and specificity 93.4% across 14,140 participants — as accurate as the dexamethasone test and urinary free cortisol, provided the assay's own cutoff is used

Shelf #6484 · Diabetes, glucose & metabolism

LIKELY (test accuracy) — late-night salivary cortisol diagnoses Cushing's syndrome with pooled sensitivity ~96% and specificity ~93%, accuracy comparable to the 1 mg dexamethasone suppression test and urinary free cortisol; cutoffs are assay-specific

Stamped: 2026-11-28.

Evidence published: 2008–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults being evaluated for Cushing's syndrome, how accurate is late-night salivary cortisol for diagnosis, and how does it compare with urinary free cortisol and the 1 mg dexamethasone suppression test?

Balance of the evidence

Two meta-analyses fourteen years apart agree that late-night salivary cortisol (LNSC) is as accurate as the other first-line Cushing's tests. Elamin 2008 pooled 27 studies (8,631 patients): positive likelihood ratios were 8.8 for midnight salivary cortisol, 10.6 for urinary free cortisol (UFC) and 16.4 for the 1 mg overnight dexamethasone suppression test (DST), with negative likelihood ratios of 0.07, 0.16 and 0.06 respectively — all highly accurate in referral populations. Galm 2020, pooling 139 studies and 14,140 participants with hierarchical models, put LNSC sensitivity at 95.8% and specificity at 93.4%, essentially level with the DST (98.6%/90.6%) and UFC (94.0%/93.0%). Primary studies add the practical caveats: in Bäcklund 2023 every assay method reached an ROC area of at least 0.96, but upper reference limits for the same 23:00 sample ranged from 3.4–3.9 nmol/L by mass spectrometry to 21.6 nmol/L for one immunoassay — the number is only interpretable against the local assay's own range. In a Chinese cohort (Lin 2019), midnight salivary cortisol at a 1.7 ng/mL cutoff gave 98% sensitivity and 100% specificity and outperformed UFC (AUC 0.99 versus 0.89). Verdict: LNSC is a first-line test of accuracy comparable to DST and UFC; its weaknesses are assay-dependent cutoffs, false positives with disturbed sleep–wake cycles or sample contamination, and false negatives in mild or intermittent disease.

MeSH: Biomarkers · Clinical Laboratory Techniques · Cushing Syndrome · Humans · Hydrocortisone · ROC Curve

Cards (5)

Card 1 — Elamin 2008 meta-analysis: salivary midnight cortisol LR+ 8.8 and LR− 0.07 — level with urinary free cortisol and the 1 mg DST (27 studies, 8,631 patients)

Study: Systematic review and meta-analysis of diagnostic accuracy studies

Population: Systematic review and meta-analyses of 27 eligible diagnostic accuracy studies (1975–2007) in patients suspected of Cushing's syndrome; 794 of 8,631 patients (9.2%) had Cushing's syndrome — a referral-enriched sample.

Summary: Elamin 2008 meta-analysis: salivary midnight cortisol LR+ 8.8 and LR− 0.07 — level with urinary free cortisol and the 1 mg DST (27 studies, 8,631 patients)

Result: The three tests had similar accuracy: urinary free cortisol (14 studies) LR+ 10.6 (95% CI 5.5–20.5) and LR− 0.16 (0.08–0.33); midnight salivary cortisol (4 studies) LR+ 8.8 (3.5–21.8) and LR− 0.07 (0–1.2); 1 mg overnight dexamethasone suppression test (14 studies) LR+ 16.4 (9.3–28.8) and LR− 0.06 (0.03–0.14). Combined strategies performed similarly. The authors cautioned that performance in usual (non-referral) clinical practice remains unclear.

Watch out: Only 4 of the 27 studies evaluated salivary cortisol, hence the very wide LR− confidence interval (0–1.2); the pooled population was enriched for severe, classic disease, which inflates accuracy for every test.

Source: Elamin MB et al. Accuracy of diagnostic tests for Cushing's syndrome: a systematic review and metaanalyses. J Clin Endocrinol Metab. 2008. PMID: 18334594. Registry ID: none in the record. MeSH: Cushing Syndrome · Dexamethasone · Humans · Hydrocortisone

Card 2 — Galm 2020 meta-analysis: late-night salivary cortisol sensitivity 95.8%, specificity 93.4% — comparable to DST and UFC (139 studies, 14,140 participants)

Study: Systematic review and meta-analysis of diagnostic accuracy studies

Population: Meta-analysis using hierarchical models of 139 studies (14,140 adult participants) evaluating the overnight 1 mg DST, 2-day low-dose DST, 24-hour UFC, late-night salivary cortisol, midnight serum cortisol and dexamethasone-suppressed CRH testing for Cushing syndrome.

Summary: Galm 2020 meta-analysis: late-night salivary cortisol sensitivity 95.8%, specificity 93.4% — comparable to DST and UFC (139 studies, 14,140 participants)

Result: Late-night salivary cortisol: sensitivity 95.8%, specificity 93.4%, LR+ 14.6 (95% CI 10.3–20.7), LR− 0.045 (0.030–0.066). Comparators: 1 mg DST sensitivity 98.6%, specificity 90.6%; UFC sensitivity 94.0%, specificity 93.0%; midnight serum cortisol sensitivity 96.1%, specificity 93.2%. Meta-regression suggested the DST is the most sensitive first-line test and UFC the least sensitive, with comparable specificity across first-line tests.

Watch out: Pooled estimates average over many assays and cutoffs; a given laboratory's salivary cortisol threshold cannot be borrowed from another assay (see card 3), and mild or cyclic disease is under-represented in the underlying studies.

Source: Galm BP et al. Accuracy of Laboratory Tests for the Diagnosis of Cushing Syndrome. J Clin Endocrinol Metab. 2020. PMID: 32133504. Registry ID: none in the record. MeSH: Biomarkers · Clinical Laboratory Techniques · Cushing Syndrome · Humans · Hydrocortisone · Meta-Analysis as Topic · Prognosis · ROC Curve

Card 3 — Assay comparison study: all six methods reached AUC ≥0.96, but the 23:00 upper reference limit ranged from 3.4 to 21.6 nmol/L by method (155 reference participants, 22 with Cushing's)

Study: Primary diagnostic method-comparison study

Population: Salivary samples at 08:00, 23:00 and 08:00 after a 1 mg DST from a reference population of 155 people and 22 patients with Cushing's syndrome, each sample measured by three LC-MS/MS methods and three immunoassays.

Summary: Assay comparison study: all six methods reached AUC ≥0.96, but the 23:00 upper reference limit ranged from 3.4 to 21.6 nmol/L by method (155 reference participants, 22 with Cushing's)

Result: Upper reference limits for 23:00 salivary cortisol were similar across LC-MS/MS methods (3.4–3.9 nmol/L) but varied widely across immunoassays: 5.8 nmol/L (Roche), 4.3 nmol/L (Salimetrics) and 21.6 nmol/L (Cisbio). Salivary cortisone limits were 13.5–16.6 nmol/L at 23:00. All methods had ROC areas under the curve of at least 0.96 for Cushing's syndrome, so accuracy was high for every method provided its own reference limit was used.

Watch out: Only 22 Cushing's patients, so the AUC estimates are imprecise; the durable lesson is the sixfold spread in immunoassay reference limits — a salivary cortisol value is meaningless without the measuring assay's own cutoff.

Source: Bäcklund N et al. Salivary cortisol and cortisone in diagnosis of Cushing's syndrome — a comparison of six different analytical methods. Clin Chem Lab Med. 2023. PMID: 37013440. Registry ID: none in the record. MeSH: Humans · Chromatography, Liquid · Cortisone · Cushing Syndrome · Hydrocortisone · Saliva · Tandem Mass Spectrometry

Card 4 — Chinese cohort: midnight salivary cortisol 98% sensitive and 100% specific at 1.7 ng/mL, AUC 0.99 versus 0.89 for urinary free cortisol (61 suspected patients, 21 controls)

Study: Primary diagnostic accuracy (case-control) study

Population: 61 Chinese patients evaluated for suspected Cushing's syndrome (48 confirmed) plus 21 healthy volunteers; midnight salivary cortisol, midnight serum cortisol and 24-hour urinary free cortisol were compared against the final diagnosis.

Summary: Chinese cohort: midnight salivary cortisol 98% sensitive and 100% specific at 1.7 ng/mL, AUC 0.99 versus 0.89 for urinary free cortisol (61 suspected patients, 21 controls)

Result: At a cutoff of 1.7 ng/mL, midnight salivary cortisol had a sensitivity of 98% and a specificity of 100%, with an area under the ROC curve of 0.99, superior to urinary free cortisol (AUC 0.89). Mean midnight salivary cortisol was 10.18 ± 1.29 ng/mL in confirmed Cushing's versus about 0.5 ng/mL in controls.

Watch out: A case-control design with healthy volunteers as part of the comparison group overstates specificity versus real clinic populations with obesity, depression or diabetes, in whom false positives concentrate.

Source: Lin DC et al. Midnight salivary cortisol for the diagnosis of Cushing's syndrome in a Chinese population. Singapore Med J. 2019. PMID: 30488082. Registry ID: none in the record. MeSH: Adult · Case-Control Studies · Cushing Syndrome · Humans · Hydrocortisone · Saliva · Time Factors · Young Adult

Card 5 — Synthesis: late-night salivary cortisol is a first-line test, equal in accuracy to the DST and UFC — the cutoff belongs to the assay, not the textbook

Study: Synthesis

Population: Over 22,000 participants across the two carded meta-analyses, plus 238 participants in the two carded primary studies.

Summary: Synthesis: late-night salivary cortisol is a first-line test, equal in accuracy to the DST and UFC — the cutoff belongs to the assay, not the textbook

Result: Pooled sensitivity/specificity for late-night salivary cortisol is about 96%/93% (Galm 2020), with likelihood ratios (LR+ 8.8–14.6, LR− 0.045–0.07) in the same range as the 1 mg dexamethasone suppression test and urinary free cortisol. No first-line test dominates; the choice turns on practicality (home saliva collection, repeatability for intermittent disease) and on using the local assay's validated late-night cutoff. LIKELY (test accuracy).

Watch out: Accuracy estimates derive largely from referral populations with a high prevalence of classic disease; in low-pretest-probability screening (for example unselected diabetes or obesity), false positives will outnumber the pooled figures' implication, and guidelines still advise confirming an abnormal first test with a second, different test.

Source: Synthesis of Elamin MB et al. J Clin Endocrinol Metab. 2008 (PMID: 18334594); Galm BP et al. J Clin Endocrinol Metab. 2020 (PMID: 32133504); Bäcklund N et al. Clin Chem Lab Med. 2023 (PMID: 37013440); Lin DC et al. Singapore Med J. 2019 (PMID: 30488082). Registry IDs: none in the records.