SourceMed · Shelf #6515 in the ask interface
CytoSorb in septic shock: the cartridge removes IL-6 (5–18% per pass) but plasma levels, organ failure and mortality did not improve in randomised trials — survival benefit unproven
Shelf #6515 · Critical care & sepsis
POSSIBLE (the treatment made no difference) — CytoSorb haemoadsorption removes cytokines per blood pass, but randomised trials show no fall in systemic IL-6, no organ-function benefit and no mortality benefit; a survival benefit is unproven
Stamped: 2026-11-28.
Evidence published: 2017–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with septic shock, does cytokine haemoadsorption (CytoSorb) reduce vasopressor requirements, organ failure or mortality versus standard care?
Balance of the evidence
POSSIBLE (the treatment made no difference) — the device removes cytokines from blood passing through it, and no randomised trial has shown that this improves organ function, vasopressor requirements or survival; a mortality benefit is unproven and must not be claimed (Tier C, mortality co-reported): The tested product is CytoSorb (CytoSorbents Corporation), a haemoadsorption cartridge — named here under the tested-product clarification exception because adsorption devices differ by maker. In septic patients with respiratory failure (Schädler D et al., PMID: 29084247; 97 analysed), CytoSorb removed interleukin-6 at 5–18% per blood pass yet systemic plasma IL-6 did not fall versus control (P=0.15), organ dysfunction, ventilation time and oxygenation did not differ, and unadjusted 60-day mortality was higher on treatment (44.7% vs 26.0%; P=0.039), a difference the authors attribute to baseline imbalance after adjustment (P=0.19). In the REMOVE trial (Diab M et al., PMID: 35213213; 288 patients having cardiac surgery for infective endocarditis), adding CytoSorb to the bypass circuit lowered some cytokines but changed neither the primary organ-dysfunction outcome (ΔSOFA 1.79 vs 1.93; P=0.68) nor 30-day mortality (21% vs 22%). The systematic review of sepsis use (Saldaña-Gastulo JJC et al., PMID: 37712812; 6 studies, 413 patients) found no mortality effect at 28–30 days and graded the certainty very low. POSSIBLE (the treatment made no difference): cytokine clearance is a laboratory fact; patient benefit is not demonstrated.
MeSH: Cardiac Surgical Procedures/adverse effects · Cytokines · Endocarditis/surgery · Endocarditis, Bacterial · Humans · Multiple Organ Failure · Treatment Outcome
Cards (4)
Card 1 — Schädler 2017 (RCT, 97 patients with sepsis and respiratory failure): CytoSorb removed IL-6 per pass but plasma IL-6 did not fall (P=0.15); unadjusted 60-day mortality was higher on treatment (44.7% vs 26.0%)
Study: Multicentre randomised controlled open-label trial (Schädler 2017)
Population: 100 patients were randomised and 97 analysed — mechanically ventilated patients with severe sepsis or septic shock and acute lung injury or ARDS in a multicentre open-label trial; CytoSorb haemoperfusion (CytoSorbents) for 6 hours per day for up to 7 days versus no haemoperfusion; primary outcome was change in normalised IL-6 concentrations over days 1–7.
Summary: Schädler 2017 (RCT, 97 patients with sepsis and respiratory failure): CytoSorb removed IL-6 per pass but plasma IL-6 did not fall (P=0.15); unadjusted 60-day mortality was higher on treatment (44.7% vs 26.0%)
Result: Significant IL-6 elimination averaging 5–18% per blood pass was recorded throughout treatment, but systemic plasma IL-6 levels did not differ between groups (n=75; P=0.15). There were no statistically significant differences in organ dysfunction score, ventilation time or oxygenation. Unadjusted 60-day mortality was significantly higher in the treatment group (44.7%) than the control group (26.0%; P=0.039); the treatment group had more renal replacement therapy at enrolment (31.9% vs 16.3%), and after adjustment for morbidity and baseline imbalances no association of haemoperfusion with mortality was found (P=0.19).
Watch out: Open-label with a sicker treatment arm at baseline (twice the renal-replacement rate), so neither the unadjusted mortality excess nor its disappearance after adjustment can bear much weight. The central lesson is mechanistic: clearing a cytokine from blood in the cartridge is not the same as lowering its level in the patient.
Source: Schädler D et al. The effect of a novel extracorporeal cytokine hemoadsorption device on IL-6 elimination in septic patients: A randomized controlled trial. PLoS One. 2017. PMID: 29084247. Registry ID: none in the record. MeSH: Aged · Cytokines/metabolism · Female · Hemoperfusion/methods · Humans · Interleukin-6/blood · Male · Middle Aged · Sepsis/blood
Estimate type: unadjusted estimate, as stated in the card.
Card 2 — REMOVE 2022 (RCT, 288 patients, endocarditis surgery): intraoperative CytoSorb did not reduce organ dysfunction (ΔSOFA 1.79 vs 1.93; P=0.68) or 30-day mortality (21% vs 22%)
Study: Multicentre randomised controlled trial (REMOVE, Diab 2022)
Population: 288 patients undergoing cardiac surgery for infective endocarditis in a multicentre randomised nonblinded trial, assigned to haemoadsorption with CytoSorb (CytoSorbents) integrated into cardiopulmonary bypass (142) or control (146); 282 underwent surgery and were analysed by modified intention to treat; primary outcome was change in Sequential Organ Failure Assessment score (ΔSOFA) to postoperative day 9.
Summary: REMOVE 2022 (RCT, 288 patients, endocarditis surgery): intraoperative CytoSorb did not reduce organ dysfunction (ΔSOFA 1.79 vs 1.93; P=0.68) or 30-day mortality (21% vs 22%)
Result: The primary outcome did not differ between groups (ΔSOFA 1.79 ± 3.75 with haemoadsorption vs 1.93 ± 3.53 control; 95% CI for the difference −1.30 to 0.83; P=0.6766). Mortality at 30 days (21% vs 22%; P=0.782), duration of mechanical ventilation, and vasopressor and renal replacement therapy did not differ. Interleukin-1β and interleukin-18 levels at the end of bypass were significantly lower with haemoadsorption. The authors conclude the trial failed to demonstrate a reduction in postoperative organ dysfunction.
Watch out: REMOVE is a surgical endocarditis population with a single intraoperative treatment during bypass, not days of therapy in medical septic shock — it tests the device in its most favourable, highest-cytokine-release setting and still found nothing. Nonblinded, though its outcomes are objective scores and mortality.
Source: Diab M et al. Cytokine Hemoadsorption During Cardiac Surgery Versus Standard Surgical Care for Infective Endocarditis (REMOVE): Results From a Multicenter Randomized Controlled Trial. Circulation. 2022. PMID: 35213213. Registry ID: ClinicalTrials.gov NCT03266302, from the record's databank fields. MeSH: Cardiac Surgical Procedures/adverse effects · Cytokines · Endocarditis/surgery · Endocarditis, Bacterial · Humans · Multiple Organ Failure · Treatment Outcome
Card 3 — Saldaña-Gastulo 2023 (systematic review and meta-analysis, 6 studies, 413 patients): no mortality effect of CytoSorb in sepsis at 28–30 days — very low certainty evidence
Study: Systematic review and meta-analysis, 6 studies (Saldaña-Gastulo 2023)
Population: Six studies (413 patients) — randomised trials and cohort studies of CytoSorb (CytoSorbents) haemoadsorption in patients with sepsis, searched in MEDLINE, Embase and the Cochrane Library; primary outcome mortality.
Summary: Saldaña-Gastulo 2023 (systematic review and meta-analysis, 6 studies, 413 patients): no mortality effect of CytoSorb in sepsis at 28–30 days — very low certainty evidence
Result: The overall mortality rate was 45%, and no significant effect on mortality was found at 28–30 days (risk ratio 0.98 relative, 95% CI 0.12 to 8.25, for the randomised trial; risk ratio 0.74 relative, 95% CI 0.49 to 1.13, for cohort studies). Meta-analysis of other outcomes was not possible for lack of data. The reviewers grade the evidence very low certainty (imprecision, risk of bias, heterogeneity), conclude there is no demonstrated benefit, and state they cannot recommend CytoSorb use in septic or septic shock patients outside clinical trials.
Watch out: Only one randomised trial sits inside this pool, with a confidence interval (0.12 to 8.25) wide enough to contain almost anything; the cohort estimate is the kind of data that flatters devices. Later meta-analyses that report lower mortality with CytoSorb rest on the same observational base and do not change the randomised picture carded here.
Source: Saldaña-Gastulo JJC et al. Cytokine hemoadsorption with CytoSorb® in patients with sepsis: a systematic review and meta-analysis. Crit Care Sci. 2023. PMID: 37712812. Registry ID: CRD42021262219, from the record's databank fields. MeSH: Humans · Cytokines · Sepsis/therapy · Shock, Septic/therapy · Cohort Studies · Randomized Controlled Trials as Topic
Card 4 — Synthesis: the cartridge clears cytokines; patients do not benefit in any randomised test — POSSIBLE (the treatment made no difference), mortality unproven
Study: Synthesis
Population: Synthesis of the cards above: two randomised trials (97 patients with sepsis and respiratory failure; 288 surgical endocarditis patients) and a 6-study systematic review (413 patients).
Summary: Synthesis: the cartridge clears cytokines; patients do not benefit in any randomised test — POSSIBLE (the treatment made no difference), mortality unproven
Result: IL-6 removal per blood pass: 5–18%, with no fall in systemic IL-6 versus control. Organ dysfunction: ΔSOFA 1.79 vs 1.93 in REMOVE; no difference in the sepsis trial. Mortality: 21% vs 22% at 30 days in REMOVE; pooled 28–30-day risk ratio 0.98 in the randomised data; the one alarming unadjusted excess (44.7% vs 26.0%) was attributed by its authors to baseline imbalance. POSSIBLE (the treatment made no difference); any claim that CytoSorb reduces vasopressor requirements or mortality in septic shock is unproven on randomised evidence.
Watch out: This shelf is about the CytoSorb cytokine adsorber specifically (CytoSorbents), named under the tested-product clarification exception; it does not answer for polymyxin-B endotoxin haemoperfusion, which is homed at live #1078.
Source: Synthesis of Schädler D et al. PLoS One. 2017. PMID: 29084247; Diab M et al. Circulation. 2022. PMID: 35213213; Saldaña-Gastulo JJC et al. Crit Care Sci. 2023. PMID: 37712812. Registry IDs as on the individual cards.
Estimate type: unadjusted estimate, as stated in the card.