Inhaled epoprostenol versus inhaled nitric oxide in ARDS: near-identical oxygenation gains in small crossover trials (PaO2/FiO2 +21 vs +29 mmHg) — no mortality data exist for the comparison
Shelf #6516 · Critical care & sepsis
MAYBE (weak evidence) — based on small crossover physiology trials (31 patients with documented N, plus one trial whose record does not report N): inhaled epoprostenol and inhaled nitric oxide improve oxygenation to a similar degree, and neither has mortality data in head-to-head comparison
Stamped: 2026-11-28.
Evidence published: 1996–2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with ARDS and refractory hypoxaemia, does inhaled epoprostenol improve oxygenation as effectively as inhaled nitric oxide — and does either change mortality?
Balance of the evidence
MAYBE (weak evidence) — on acute oxygenation the two inhaled vasodilators look equivalent in tiny crossover physiology trials; on mortality and every patient-important outcome there are no comparative data at all (Tier C): In the direct randomised crossover comparison (Walmrath D et al., PMID: 8630585; 16 patients with ARDS), individually titrated inhaled nitric oxide (mean 17.8 ppm) raised PaO2/FiO2 from 115 to 144 mmHg and aerosolised prostacyclin (epoprostenol; mean 7.5 ng/kg/min) from 114 to 135 mmHg, with shunt falling by about 7 points on each and near-identical efficacy profiles. A dose-response crossover study (Zwissler B et al., PMID: 8970353) found the same pattern — both agents selectively lowered pulmonary artery pressure and raised PaO2/FiO2 — in a record that does not report its patient number. A later three-way crossover pilot (Albert M et al., PMID: 28224110; 15 patients) found median PaO2 rises of 8.8 mmHg on nitric oxide and 6.0 mmHg on epoprostenol, with only nitric oxide reaching significance in that small sample. Each drug's effect against control is homed separately — inhaled nitric oxide at live #1323 (oxygenation improves briefly, outcomes do not) and inhaled prostacyclin at pack #3172 (a negative multicentre trial against placebo) — and neither home is re-carded here. MAYBE (weak evidence): epoprostenol is a physiologically credible, cheaper substitute for nitric oxide for short-term oxygenation rescue; equivalence on survival is unknown, not established.
MeSH: Administration, Inhalation · Adult · Aerosols · Aged · Blood Pressure/drug effects · Epoprostenol/therapeutic use · Female · Hemodynamics/drug effects · Humans · Lung/blood supply · Male · Middle Aged · Nitric Oxide/therapeutic use · Oxygen/blood · Oxygen Consumption/drug effects · Pulmonary Artery · Pulmonary Circulation/drug effects · Pulmonary Gas Exchange/drug effects · Respiration, Artificial · Respiratory Distress Syndrome/drug therapy · Respiratory System Agents/therapeutic use · Vasodilator Agents/therapeutic use
Cards (4)
Card 1 — Walmrath 1996 (randomised crossover, 16 ARDS patients): inhaled nitric oxide raised PaO2/FiO2 115 → 144 mmHg and aerosolised prostacyclin 114 → 135 mmHg — nearly identical efficacy profiles
Study: Randomised crossover comparison (Walmrath 1996) — N = 16
Population: 16 mechanically ventilated patients with ARDS (mean lung injury score 2.75), randomised to receive first inhaled nitric oxide then aerosolised prostacyclin (epoprostenol), or vice versa; each drug was individually titrated for maximum improvement in arterial oxygenation, with gas exchange measured including the multiple inert gas elimination technique.
Summary: Walmrath 1996 (randomised crossover, 16 ARDS patients): inhaled nitric oxide raised PaO2/FiO2 115 → 144 mmHg and aerosolised prostacyclin 114 → 135 mmHg — nearly identical efficacy profiles
Result: Inhaled nitric oxide (17.8 ± 2.7 ppm) increased PaO2/FiO2 from 115 ± 12 to 144 ± 15 mmHg (P<0.01) and reduced shunt flow from 33.1% to 26.6% (P<0.05). Aerosolised prostacyclin (7.5 ± 2.5 ng/kg/min) augmented PaO2/FiO2 from 114 ± 12 to 135 ± 12 mmHg (P<0.01) and decreased shunt from 33.5% to 26.0% (P<0.05). In 10 patients both agents raised PaO2/FiO2 by at least 10 mmHg; two further patients responded to one agent only. Nitric oxide lowered mean pulmonary artery pressure from 34.8 to 33.0 mmHg and prostacyclin from 35.0 to 31.9 mmHg (P<0.05). The authors conclude the two have nearly identical efficacy profiles. No mortality or ventilation-duration outcomes were studied.
Watch out: A 16-patient, single-session physiology study from 1996: it compares oxygenation over minutes to hours, in an era of non-protective ventilation, and says nothing about survival, ventilation days or harm. Titrated-to-best-dose designs also flatter both drugs equally, which is the point of the comparison but limits any absolute claim.
Source: Walmrath D et al. Direct comparison of inhaled nitric oxide and aerosolized prostacyclin in acute respiratory distress syndrome. Am J Respir Crit Care Med. 1996. PMID: 8630585. Registry ID: none in the record. MeSH: Administration, Inhalation · Adult · Aerosols · Aged · Blood Pressure/drug effects · Epoprostenol/therapeutic use · Female · Hemodynamics/drug effects · Humans · Lung/blood supply · Male · Middle Aged · Nitric Oxide/therapeutic use · Oxygen/blood · Oxygen Consumption/drug effects · Pulmonary Artery · Pulmonary Circulation/drug effects · Pulmonary Gas Exchange/drug effects · Respiration, Artificial · Respiratory Distress Syndrome/drug therapy · Respiratory System Agents/therapeutic use · Vasodilator Agents/therapeutic use
Card 2 — Zwissler 1996 (dose-response crossover): inhaled prostacyclin lowered pulmonary artery pressure dose-dependently (35.1 → 29.6 mmHg) and raised PaO2/FiO2 to 131 mmHg, matching nitric oxide (patient number not reported in the record)
Study: Dose-response crossover comparison (Zwissler 1996) — N not documented in the record
Population: Patients with adult respiratory distress syndrome receiving, in crossover fashion, inhaled prostacyclin (epoprostenol) at 1, 10 and 25 ng/kg/min and inhaled nitric oxide at 1, 4 and 8 ppm, with cardiorespiratory measurements at control, at each dose and after withdrawal. The record does not report the number of patients — N not documented in the record.
Summary: Zwissler 1996 (dose-response crossover): inhaled prostacyclin lowered pulmonary artery pressure dose-dependently (35.1 → 29.6 mmHg) and raised PaO2/FiO2 to 131 mmHg, matching nitric oxide (patient number not reported in the record)
Result: Prostacyclin produced a dose-dependent selective fall in pulmonary artery pressure, from 35.1 ± 6.3 mmHg at control to 29.6 ± 4.5 mmHg at 25 ng/kg/min, and raised PaO2/FiO2 from 105 ± 37 to 125 ± 56 mmHg at 10 ng/kg/min and 131 ± 63 mmHg at 25 ng/kg/min, with no effect at 1 ng/kg/min. Nitric oxide reduced pulmonary artery pressure from 34.5 ± 5.6 to 31.8 ± 6.1 mmHg at 8 ppm (no effect at 1 ppm), improved PaO2 (116 ± 47 to 167 ± 86 mmHg at 8 ppm) and reduced intrapulmonary shunt at all doses tested. The authors conclude both compounds induce selective pulmonary vasodilation and increase PaO2 in severe ARDS.
Watch out: The patient number is not printed in the record, so this card carries no N — treat it as a small physiology study by design (dose-response crossovers of this era enrolled handfuls of patients). Inter-individual responses ranged widely, including patients whose oxygenation fell on prostacyclin (range −5 to +89 mmHg at the top dose).
Source: Zwissler B et al. Inhaled prostacyclin (PGI2) versus inhaled nitric oxide in adult respiratory distress syndrome. Am J Respir Crit Care Med. 1996. PMID: 8970353. Registry ID: none in the record. MeSH: APACHE · Administration, Inhalation · Adult · Dose-Response Relationship, Drug · Epoprostenol/administration & dosage · Female · Hemodynamics/drug effects · Humans · Male · Middle Aged · Nitric Oxide/administration & dosage · Pulmonary Circulation/drug effects · Pulmonary Gas Exchange/drug effects · Respiratory Distress Syndrome/drug therapy · Vasodilation/drug effects · Vasodilator Agents/administration & dosage
Card 3 — Albert 2017 (crossover pilot, 15 ARDS patients): median PaO2 rise 8.8 mmHg on nitric oxide vs 6.0 mmHg on epoprostenol — only nitric oxide's rise was significant in this small sample
Study: Open-label prospective crossover pilot (Albert 2017) — N = 15
Population: 15 adult patients with ARDS and hypoxaemic failure monitored with a pulmonary artery catheter in a single academic ICU, in an open-label prospective crossover pilot; random sequential administration of inhaled nitric oxide (20 ppm) or nebulised epoprostenol (10 μg/mL), followed by inhaled milrinone arms that are outside this shelf's question.
Summary: Albert 2017 (crossover pilot, 15 ARDS patients): median PaO2 rise 8.8 mmHg on nitric oxide vs 6.0 mmHg on epoprostenol — only nitric oxide's rise was significant in this small sample
Result: Neither agent affected systemic haemodynamics and no significant drug-related adverse events were observed. The median increase in PaO2 from baseline was 8.8 mmHg (IQR 16.3) with inhaled nitric oxide and 6.0 mmHg (IQR 18.4) with epoprostenol; only nitric oxide (and the milrinone–nitric oxide combination) had a statistically significant effect on PaO2 in this sample. No mortality or ventilation outcomes were studied.
Watch out: Fifteen patients and a fixed (not titrated) epoprostenol concentration: the non-significant epoprostenol result may reflect dose and power rather than inferiority, and the study's primary interest was milrinone. It is carded as the only modern-era head-to-head, not as a verdict.
Source: Albert M et al. Comparison of inhaled milrinone, nitric oxide and prostacyclin in acute respiratory distress syndrome. World J Crit Care Med. 2017. PMID: 28224110. Registry ID: none in the record. MeSH: not captured from the record
Card 4 — Synthesis: equivalent acute oxygenation in 31 patients with documented numbers — and no mortality data anywhere in the head-to-head literature (MAYBE, weak evidence)
Study: Synthesis
Population: Synthesis of the cards above: three crossover physiology comparisons (16 and 15 patients with documented numbers; one further trial whose record does not report N).
Summary: Synthesis: equivalent acute oxygenation in 31 patients with documented numbers — and no mortality data anywhere in the head-to-head literature (MAYBE, weak evidence)
Result: PaO2/FiO2 gains were of the same order for both drugs in the titrated comparison (+29 mmHg nitric oxide, +21 mmHg prostacyclin) and pulmonary artery pressure fell selectively with both. No head-to-head study reports mortality, ventilator-free days or length of stay. MAYBE (weak evidence) — the honest claim is physiological interchangeability for rescue oxygenation, nothing more.
Watch out: Each drug versus control is a separate shelf — live #1323 for inhaled nitric oxide (brief oxygenation gain, no outcome benefit) and pack #3172 for inhaled prostacyclin (negative primary endpoint against placebo) — and those verdicts bound what this head-to-head can mean: two agents can be equivalent to each other while neither improves survival.
Source: Synthesis of Walmrath D et al. Am J Respir Crit Care Med. 1996. PMID: 8630585; Zwissler B et al. Am J Respir Crit Care Med. 1996. PMID: 8970353; Albert M et al. World J Crit Care Med. 2017. PMID: 28224110. Registry IDs as on the individual cards (none).