SourceMed · Shelf #6520 in the ask interface

Pendelluft and patient self-inflicted lung injury: gas shifts to dependent lung when effort is strong — shown on tomography in human ARDS and scaled to effort in 20 patients, but human injury evidence rests on a single-patient observation and animal mechanics

Shelf #6520 · Critical care & sepsis

PHYSIOLOGY — EMERGING — pendelluft occurs in human ARDS and scales with inspiratory effort, and effort can be measured non-invasively (ΔPocc, P0.1); direct human evidence that vigorous effort worsens lung injury (P-SILI) is limited to a one-patient observation plus animal mechanics

Stamped: 2026-11-28.

Evidence published: 2013–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In spontaneously breathing patients with injured lungs, what is pendelluft, how strong is the human evidence that vigorous inspiratory effort worsens lung injury (patient self-inflicted lung injury), and how is effort measured at the bedside?

Balance of the evidence

PHYSIOLOGY — EMERGING (textbook framing: Guyton & Hall Textbook of Medical Physiology and Boron & Boulpaep Medical Physiology, on pleural-pressure transmission and regional lung stress): Pendelluft is gas moving inside the lung from non-dependent to dependent regions at the start of inspiration — without any change in tidal volume at the airway — when a strong diaphragmatic contraction drops pleural pressure locally, in dependent lung, instead of uniformly. The concept entered human medicine through a single-patient electrical impedance tomography observation during mechanical ventilation, after which the same group demonstrated the mechanism experimentally in injured pig lungs (Yoshida T et al., PMID: 24199628): the human component of that paper is one patient (N = 1, printed on the face), and its quantitative mechanics are animal data, labelled as such on the card and not treated as human evidence. Human cohort data now confirm the phenomenon is real and effort-dependent: in 20 ventilated ARDS patients, pendelluft during patient-triggered breaths grew with oesophageal pressure swing, with distinct high- and low-pendelluft response patterns (Lin WC et al., PMID: 38092775). What remains unproven in humans is the injury claim itself — patient self-inflicted lung injury (P-SILI): no human study carded here shows pendelluft or effort causing worse lung injury or death. Effort, at least, can be measured at the bedside: a brief airway occlusion swing (ΔPocc) detected muscle pressure above 10 cm H2O with AUROC 0.92 and transpulmonary driving pressure above 15 cm H2O with AUROC 0.93 in 16 patients, validated in 12 more (Bertoni M et al., PMID: 31694692), and ventilator-displayed occlusion pressure (P0.1) tracks drive and flags potentially injurious effort (Telias I et al., PMID: 32097569). PHYSIOLOGY — EMERGING: pendelluft exists in human ARDS and scales with effort; effort is measurable non-invasively; that vigorous effort worsens human lung injury is a coherent, experimentally grounded hypothesis without direct human outcome evidence.

MeSH: Humans · Positive-Pressure Respiration/methods · Retrospective Studies · Respiratory Distress Syndrome/therapy · Lung/physiology · Respiration, Artificial/methods

Cards (5)

Card 1 — Yoshida 2013: pendelluft seen on impedance tomography in one ventilated patient with injured lungs (human N = 1) — the mechanism then demonstrated in injured pig lungs (animal data, labelled)

Study: Human case observation (N = 1) with animal mechanistic experiments (Yoshida 2013)

Population: Human component: a single patient with injured lungs undergoing mechanical ventilation, in whom electrical impedance tomography showed air moving from non-dependent to dependent lung regions during spontaneous breathing effort without change in tidal volume — N = 1, printed on the face as the physiology labelling rule requires. Experimental component (animal, not human evidence): anaesthetised pigs with lung injury studied with impedance tomography, dynamic CT and intrabronchial pleural-pressure catheters.

Summary: Yoshida 2013: pendelluft seen on impedance tomography in one ventilated patient with injured lungs (human N = 1) — the mechanism then demonstrated in injured pig lungs (animal data, labelled)

Result: In the patient, spontaneous breathing during mechanical ventilation produced pendelluft visible on impedance tomography. In the animal experiments, spontaneous effort made dependent pleural pressure far more negative than non-dependent (−13.0 ± 4.0 vs −6.4 ± 3.8 cm H2O; P<0.05), pendelluft occurred during early inflation despite tidal volume limited below 6 mL/kg, and matching the dependent inflation under paralysis required almost threefold greater driving pressure (28.0 ± 0.5 vs 10.3 ± 0.6 cm H2O; P<0.01) — that is, effort overstretched dependent lung at unchanged tidal volume. The authors conclude strong spontaneous effort may enhance lung damage even when it does not increase tidal volume.

Watch out: Read the denominators: the human evidence in this founding paper is one patient's tomogram; every number on this card except the existence of the phenomenon in that patient comes from pigs. It is carded because it is the origin of the concept and its human observation is genuine — not because its mechanics are human data.

Source: Yoshida T et al. Spontaneous effort causes occult pendelluft during mechanical ventilation. Am J Respir Crit Care Med. 2013. PMID: 24199628. Registry ID: none in the record. MeSH: Adult · Animals · Humans · Lung/physiopathology · Male · Plethysmography, Impedance · Pleura/physiopathology · Positive-Pressure Respiration · Pressure · Respiration · Respiratory Distress Syndrome/physiopathology · Swine · Tidal Volume · Tomography

Card 2 — Lin 2023 (20 ARDS patients): pendelluft during triggered breaths scaled with breathing effort (oesophageal pressure swing), with distinct high- and low-response patterns

Study: Prospective physiological cohort study (Lin 2023) — N = 20

Population: 20 mechanically ventilated patients with ARDS during transition from controlled to active breaths under volume-cycled ventilation, studied prospectively with electrical impedance tomography plus respiratory mechanics; breaths were grouped by oesophageal pressure swing (ΔPes): low (<5 cm H2O; 471 breaths), moderate (5 to <10 cm H2O; 906 breaths) and high effort (≥10 cm H2O; 565 breaths).

Summary: Lin 2023 (20 ARDS patients): pendelluft during triggered breaths scaled with breathing effort (oesophageal pressure swing), with distinct high- and low-response patterns

Result: The pendelluft response to breathing effort was significantly greater in patient-triggered breaths than in reverse-triggered breaths (P<0.0001). By pendelluft-ΔPes slope, patients split into a high-pendelluft group (n=9; slope 0.7–2.4 mL/cm H2O) and a low-pendelluft group (n=11; slope −0.1 to 0.3 mL/cm H2O); for triggered breaths the high group had lower peak/plateau pressures and lower respiratory-system and lung elastance. Using ΔPes to predict pendelluft had a low positive predictive value. No clinical outcomes were measured.

Watch out: Twenty patients, breath-level analysis (thousands of breaths are not thousands of patients), and a retrospectively analysed dataset. It establishes that pendelluft occurs and is effort-related in human ARDS — and, usefully, that effort alone predicts it poorly, so the phenomenon cannot be inferred from the ventilator screen alone.

Source: Lin WC et al. Pendelluft in patients with acute respiratory distress syndrome during trigger and reverse triggering breaths. Sci Rep. 2023. PMID: 38092775. Registry ID: none in the record. MeSH: Humans · Positive-Pressure Respiration/methods · Retrospective Studies · Respiratory Distress Syndrome/therapy · Lung/physiology · Respiration, Artificial/methods

Card 3 — Bertoni 2019 (16 patients + 12-patient validation): a brief occlusion swing (ΔPocc) detected excessive effort — muscle pressure >10 cm H2O with AUROC 0.92, transpulmonary driving pressure >15 cm H2O with AUROC 0.93

Study: Physiological validation study (Bertoni 2019) — N = 16 + 12

Population: Mechanically ventilated patients in two Toronto ICUs, with daily measurements of respiratory muscle pressure (Pmus), dynamic transpulmonary driving pressure (ΔPL,dyn) and the airway-pressure swing during a brief end-expiratory occlusion (ΔPocc): 52 recordings in 16 patients for derivation, and an independent external validation cohort of 12 patients in Nanjing, China.

Summary: Bertoni 2019 (16 patients + 12-patient validation): a brief occlusion swing (ΔPocc) detected excessive effort — muscle pressure >10 cm H2O with AUROC 0.92, transpulmonary driving pressure >15 cm H2O with AUROC 0.93

Result: Excessive effort was frequent: Pmus exceeded 10 cm H2O on 84% of study days and ΔPL,dyn exceeded 15 cm H2O on 53%. ΔPocc accurately detected Pmus >10 cm H2O (AUROC 0.92, 95% CI 0.83 to 0.97) and ΔPL,dyn >15 cm H2O (AUROC 0.93, 95% CI 0.86 to 0.99), and in the external cohort estimated values detected both conditions with AUROC ≥0.94. The authors conclude measuring ΔPocc enables accurate non-invasive screening for elevated respiratory muscle pressure and transpulmonary driving pressure.

Watch out: The thresholds (Pmus 10, ΔPL 15 cm H2O) are the investigators' definitions of 'excessive', chosen from the P-SILI framework itself — the study validates a measurement against those definitions, not the definitions against patient outcomes. Twenty-eight patients in total is a small validation base.

Source: Bertoni M et al. A novel non-invasive method to detect excessively high respiratory effort and dynamic transpulmonary driving pressure during mechanical ventilation. Crit Care. 2019. PMID: 31694692. Registry ID: none in the record. MeSH: Acute Lung Injury/physiopathology · Aged · Female · Humans · Male · Middle Aged · Monitoring, Physiologic/methods · Noninvasive Ventilation/methods · Pressure · Respiration, Artificial/methods · Respiratory Muscles/injuries · Weights and Measures/instrumentation · Work of Breathing/physiology

Card 4 — Telias 2020: airway occlusion pressure (P0.1) is a reliable bedside estimate of drive and effort — P0.1 above 3.5 cm H2O was 80% sensitive for high effort (patient number not reported in the record)

Study: Physiological validation studies (Telias 2020) — N not documented in the record

Population: Patients under assisted ventilation (three patient studies) and healthy subjects (one study), plus a bench study of six ventilators; ventilator-displayed P0.1 was validated against diaphragmatic electrical activity, muscular pressure-time measures and a reference occlusion P0.1, with oesophageal pressure-time product as the reference standard for effort. The record does not print the total patient number — N not documented in the record.

Summary: Telias 2020: airway occlusion pressure (P0.1) is a reliable bedside estimate of drive and effort — P0.1 above 3.5 cm H2O was 80% sensitive for high effort (patient number not reported in the record)

Result: Ventilator P0.1 correlated well with measures of drive and with the oesophageal pressure-time product (within-subjects R²=0.8). A reference P0.1 above 3.5 cm H2O was 80% sensitive and 77% specific for detecting high effort (≥200 cm H2O·s·min⁻¹), and P0.1 at or below 1.0 cm H2O was 100% sensitive and 92% specific for low effort (≤50 cm H2O·s·min⁻¹); areas under the curve for ventilator P0.1 were 0.81 (high effort) and 0.92 (low effort). Bench testing showed low mean bias for most ventilators but variable precision, worse in patients.

Watch out: P0.1 measures drive in the first 100 milliseconds of an occluded breath — a proxy for effort, not effort itself, and ventilators that estimate it without a true occlusion can underestimate it. Like the ΔPocc card, it validates detection of a physiological state whose harmfulness in humans is the unproven part of P-SILI.

Source: Telias I et al. Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation. Am J Respir Crit Care Med. 2020. PMID: 32097569. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Air Pressure · Biological Monitoring/standards · Female · Humans · Inhalation/physiology · Male · Middle Aged · Positive-Pressure Respiration/standards · Practice Guidelines as Topic · Reproducibility of Results · Respiration, Artificial/standards · Work of Breathing/physiology

Card 5 — Synthesis: pendelluft is real and effort-scaled in human ARDS, effort is measurable at the bedside — and direct human evidence that effort injures the lung does not yet exist (PHYSIOLOGY — EMERGING)

Study: Synthesis

Population: Synthesis of the cards above: a one-patient founding observation with animal mechanics, a 20-patient ARDS cohort, and two effort-measurement validation studies (16 + 12 patients; one with N not documented).

Summary: Synthesis: pendelluft is real and effort-scaled in human ARDS, effort is measurable at the bedside — and direct human evidence that effort injures the lung does not yet exist (PHYSIOLOGY — EMERGING)

Result: Existence: pendelluft demonstrated on tomography in ventilated human ARDS, scaling with oesophageal pressure swing. Mechanism: dependent overstretch at unchanged tidal volume — demonstrated in animals, inferred in humans. Measurement: ΔPocc (AUROC 0.92–0.93) and P0.1 (AUROC 0.81–0.92) detect high effort non-invasively. Outcomes: no carded human study links pendelluft or effort to worsened injury or mortality. PHYSIOLOGY — EMERGING, with the human-data limit stated plainly.

Watch out: P-SILI is routinely invoked to justify deep sedation or paralysis decisions; this shelf's evidence supports monitoring effort, not any particular response to it. The Brochard/Goligher review literature frames the hypothesis — reviews are discussed in the balance, not carded, because they are not primary human data.

Source: Synthesis of Yoshida T et al. Am J Respir Crit Care Med. 2013. PMID: 24199628; Lin WC et al. Sci Rep. 2023. PMID: 38092775; Bertoni M et al. Crit Care. 2019. PMID: 31694692; Telias I et al. Am J Respir Crit Care Med. 2020. PMID: 32097569. Registry IDs as on the individual cards (none).