SourceMed · Shelf #6587 in the ask interface
Segesterone acetate/ethinyl estradiol one-year vaginal ring (tested product: the Population Council/TherapeuticsMD segesterone ring, Annovera) — SINGLE-ARM phase 3 programme in 2,265 women: Pearl Index 2.98 per 100 woman-years in women aged 35 and under; venous thromboembolism in 4 of 2,308 users of the final ring (0.2%)
Shelf #6587 · Women’s health
POSSIBLE (benefit) — single-arm phase 3 programme only (design printed): Pearl Index 2.98 per 100 woman-years (age ≤35 subgroup), 97.5% Kaplan–Meier effectiveness; VTE 0.2% in the safety population; no randomised comparison
Stamped: 2026-11-28.
Evidence published: 2019–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In women seeking contraception, does the segesterone acetate + ethinyl estradiol vaginal ring used in 21/7 cycles for up to 13 cycles (name the tested product — Population Council/TherapeuticsMD segesterone ring) prevent pregnancy as effectively as benchmark combined hormonal contraception, and what are its discontinuation and VTE profiles?
Balance of the evidence
POSSIBLE (benefit) — effective contraception on a single-arm programme, with the design printed: both phase 3 trials of the tested product (the Population Council/TherapeuticsMD segesterone acetate/ethinyl estradiol vaginal system, Annovera, releasing an average of 0.15 mg segesterone acetate and 0.013 mg ethinyl estradiol daily, used 21 days in / 7 days out for up to 13 cycles with the same ring) were open-label and single-arm, so efficacy is judged against regulatory benchmarks, not against a concurrent comparator. In 2,265 women in the efficacy analysis, the Pearl Index in the primary group (women aged 35 years and younger) was 2.98 per 100 woman-years (95% CI 2.13–4.06), and Kaplan–Meier analysis estimated the ring 97.5% effective over 13 cycles; 57.5% of participants completed 13 cycles. In the integrated safety analysis (2,308 women using the final manufactured ring), headache (26%), nausea (18%) and vaginal discharge/mycotic infection (10%) were most common, few women (under 1.5%) discontinued for these, and four women (0.2%) had venous thromboembolism — three of whom had risk factors (a Factor V Leiden mutation, or body mass index above 29 kg/m2). Satisfaction among prior pill/ring users was high (at least 90%). A single programme with no randomised comparator caps the stamp at POSSIBLE.
MeSH: Adolescent · Adult · Clinical Trials, Phase III as Topic · Contraceptive Devices, Female · Drug Combinations · Ethinyl Estradiol · Female · Humans · Infusion Pumps, Implantable · Outcome Assessment, Health Care · Pregnenediones · Treatment Outcome · Young Adult
Cards (4)
Card 1 — Archer 2019 — phase 3 programme, SINGLE-ARM open-label (design printed): 2,265 women in the efficacy analysis; Pearl Index 2.98 per 100 woman-years in women aged ≤35; 97.5% effective by Kaplan–Meier over 13 cycles
Study: Phase 3 single-arm trials (Archer 2019)
Population: 2,278 women enrolled across two identically designed multicentre, open-label, single-arm phase 3 trials (15 US sites; 12 US and international sites) of the tested product — the Population Council/TherapeuticsMD segesterone acetate/ethinyl estradiol contraceptive vaginal system (Annovera) — in healthy, sexually active, non-pregnant, non-sterilised women aged 18–40 years, using the same ring 21 days in and 7 days out for up to 13 cycles; removals during the 21 days were not to exceed 2 hours. The efficacy analysis included 2,265 participants (1,130 US; 1,135 international), and 1,303 (57.5%) completed up to 13 cycles.
Summary: Archer 2019 — phase 3 programme, SINGLE-ARM open-label (design printed): 2,265 women in the efficacy analysis; Pearl Index 2.98 per 100 woman-years in women aged ≤35; 97.5% effective by Kaplan–Meier over 13 cycles
Result: The Pearl Index for the primary efficacy group (women aged 35 years and younger, excluding adjunctive-contraception cycles) was 2.98 (95% CI 2.13–4.06) per 100 woman-years — within the range regulators accept as efficacy for a user-controlled contraceptive. Kaplan–Meier analysis estimated the vaginal system 97.5% effective, and pregnancy occurrence was similar across cycles. All 290 women followed after the trials reported return to menses or became pregnant within 6 months, including 24 of 38 (63%) who desired pregnancy.
Watch out: Single-arm design printed on the face: with no concurrent control group, the Pearl Index is a benchmark comparison, not a randomised effect — and 42.5% of participants did not complete 13 cycles, so the estimate rests heavily on the cycles actually observed.
Source: Archer DF et al. Efficacy of the 1-year (13-cycle) segesterone acetate and ethinylestradiol contraceptive vaginal system: results of two multicentre, open-label, single-arm, phase 3 trials. The Lancet Global Health. 2019. PMID: 31231065. Registry ID: ClinicalTrials.gov NCT00455156 and NCT00263341, from the record. MeSH: Adolescent · Adult · Clinical Trials, Phase III as Topic · Contraceptive Devices, Female · Drug Combinations · Ethinyl Estradiol · Female · Humans · Infusion Pumps, Implantable · Outcome Assessment, Health Care · Pregnenediones · Treatment Outcome · Young Adult
Card 2 — Gemzell-Danielsson 2019 — integrated safety (3,052 women in nine studies; 2,308 on the final ring): headache 26%, nausea 18%; venous thromboembolism in 4 women (0.2%), three with risk factors; partial or complete expulsion in about a quarter of cycles
Study: Integrated safety evaluation (Gemzell-Danielsson 2019)
Population: Integrated data from nine studies of the segesterone acetate/ethinyl estradiol contraceptive vaginal system (21 days in / 7 days out), including 3,052 women overall and 2,308 women (mean age 26.7 years; mean body mass index 24.1 kg/m2) who received the final manufactured ring, of whom 999 (43.3%) completed 13 cycles; safety-focused substudies covered endometrial biopsies, vaginal microbiology and liver proteins.
Summary: Gemzell-Danielsson 2019 — integrated safety (3,052 women in nine studies; 2,308 on the final ring): headache 26%, nausea 18%; venous thromboembolism in 4 women (0.2%), three with risk factors; partial or complete expulsion in about a quarter of cycles
Result: The most common adverse events on the final ring were headache (601 women, 26%), nausea (420, 18%), vaginal discharge/vulvovaginal mycotic infection (242, 10%) and abdominal pain (225, 10%); fewer than 1.5% of women discontinued for these complaints. Four women (0.2%) experienced venous thromboembolism, three of whom had risk factors for thrombosis (Factor V Leiden mutation in one; body mass index above 29 kg/m2 in two). Across 21,482 phase 3 cycles evaluable for expulsion, partial expulsions were reported in 19.5% of cycles and complete expulsions in 7%, most often in the first cycle. The focused safety studies revealed no additional concerns, and the authors judged the profile similar to other combined hormonal contraceptives, with the same prescribing precautions.
Watch out: The safety population was young and lean (mean body mass index 24.1 kg/m2); the authors themselves call for more study in women with obesity, who carry higher venous thromboembolism risk — four events in 2,308 users cannot pin down a rare-event rate.
Source: Gemzell-Danielsson K et al. Segesterone acetate/ethinyl estradiol 12-month contraceptive vaginal system safety evaluation. Contraception. 2019. PMID: 30831102. Registry ID: none in the record. MeSH: Adult · Contraceptive Devices, Female/adverse effects · Drug Combinations · Ethinyl Estradiol/adverse effects · Female · Humans · Pregnenediones/adverse effects · Young Adult
Card 3 — Jensen 2023 — satisfaction in prior pill/ring users: at least 90% satisfied with the one-year ring; ease of use and 1-year duration the most-liked features, insertion and feeling it come out the most disliked
Study: Post-hoc satisfaction analysis (Jensen 2023)
Population: Participants in the multinational phase 3 trial with documented recent use of a monthly contraceptive vaginal ring (128 at cycle 3; 92 at end of study) or oral contraceptive pills (219 at cycle 3; 148 at end of study) before enrolment, drawn from 1,033 survey participants at cycle 3 and 622 at end of study (end of study required at least 10 completed cycles).
Summary: Jensen 2023 — satisfaction in prior pill/ring users: at least 90% satisfied with the one-year ring; ease of use and 1-year duration the most-liked features, insertion and feeling it come out the most disliked
Result: Overall satisfaction with the vaginal system was high (at least 90%) in both switcher groups. At end of study, 89% of recent ring users and 97% of recent pill users liked the system as much as or better than any previous method; the most-liked features were ease of use and the 1-year duration, and the most disliked were ring insertion and feeling it coming out. At least 88% of both groups had no concern about using the same ring for a year, and more than 80% had recommended it to friends or family.
Watch out: Post-hoc and survivor-shaped: end-of-study responses come only from women who persisted for at least 10 cycles, so satisfaction among the many women who stopped early — the group whose experience decides real-world acceptability — is not captured here.
Source: Jensen JT et al. Satisfaction with a Segesterone Acetate and Ethinyl Estradiol Contraceptive Vaginal System Among Recent Oral Contraceptive or Hormonal Contraceptive Vaginal Ring Users. Journal of Women's Health. 2023. PMID: 37253139. Registry ID: ClinicalTrials.gov NCT00263341, from the record. MeSH: Female · Humans · Contraceptive Agents, Female · Contraceptive Devices, Female · Contraceptives, Oral · Ethinyl Estradiol · Drug Combinations · Pregnenediones
Card 4 — Synthesis: one ring for a year prevents pregnancy at a Pearl Index of about 3 in the regulatory subgroup, with a combined-hormonal-contraceptive harm profile — on single-arm evidence
Study: Synthesis
Population: The tested product (Annovera) across its programme: 2,265 women in the efficacy analysis and 2,308 users of the final manufactured ring in the safety analysis, all in open-label, single-arm studies.
Summary: Synthesis: one ring for a year prevents pregnancy at a Pearl Index of about 3 in the regulatory subgroup, with a combined-hormonal-contraceptive harm profile — on single-arm evidence
Result: Efficacy: Pearl Index 2.98 per 100 woman-years in women aged 35 and under and 97.5% Kaplan–Meier effectiveness over 13 cycles, with return to menses or pregnancy documented after use. Harms: mostly headache, nausea and vaginal symptoms, under 1.5% discontinuing for them, expulsions in about a quarter of cycles, and venous thromboembolism in 0.2% — three of the four cases with pre-existing risk factors. Acceptability among women who stayed on it was high.
Watch out: Everything rests on one sponsor programme without a randomised comparator, in young, mostly non-obese women; the convenience claim (no refills for a year) is real, but comparative effectiveness and the venous thromboembolism rate in higher-risk users remain benchmark judgements, not measured differences.
Source: Synthesis of Archer DF et al. The Lancet Global Health. 2019 (PMID: 31231065); Gemzell-Danielsson K et al. Contraception. 2019 (PMID: 30831102); Jensen JT et al. Journal of Women's Health. 2023 (PMID: 37253139).