SourceMed · Shelf #6589 in the ask interface

PlGF-based testing for suspected preterm pre-eclampsia: an sFlt-1/PlGF ratio of 38 or lower rules out pre-eclampsia within a week with 99.3% negative predictive value; revealing the result halved time to diagnosis (1.9 vs 4.1 days), but REPEAT testing (PARROT-2) made no difference to perinatal outcomes

Shelf #6589 · Women’s health

POSSIBLE (benefit) — single revealed PlGF test: NPV 99.3% at ratio ≤38 (accuracy) and faster diagnosis with fewer severe maternal outcomes in one cluster trial (outcomes); repeat testing NULL in PARROT-2 (31.2% vs 27.8%, p=0.18; the treatment made no difference)

Stamped: 2026-11-28.

Evidence published: 2016–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women presenting with suspected preterm pre-eclampsia, does revealing a PlGF-based test result (PlGF alone or sFlt-1/PlGF ratio) to clinicians shorten time to diagnosis and improve maternal/perinatal outcomes versus concealed testing/usual care — and how accurately does the test rule out pre-eclampsia within 1–2 weeks?

Balance of the evidence

POSSIBLE (benefit) for a single revealed test as a diagnostic strategy; repeat testing is a null. Accuracy first (accuracy figures stated as accuracy): in PROGNOSIS (Zeisler 2016; 500-woman development cohort plus 550-woman validation cohort), an sFlt-1/PlGF ratio of 38 or lower had a negative predictive value of 99.3% (95% CI 97.9–99.9) for absence of pre-eclampsia within 1 week, with 80.0% sensitivity and 78.3% specificity; a ratio above 38 had a positive predictive value of only 36.7% for pre-eclampsia within 4 weeks — the test rules out far better than it rules in. Strategy next (strategy outcomes stated as outcomes): in PARROT (Duhig 2019; stepped-wedge cluster trial, 1,023 women), revealing the PlGF result with a management algorithm cut median time to diagnosis from 4.1 to 1.9 days (time ratio 0.36, 95% CI 0.15–0.87) and severe maternal adverse outcomes were less frequent (4% versus 5%; adjusted odds ratio 0.32, 95% CI 0.11–0.96), with no difference in perinatal adverse outcomes (15% versus 14%) or gestation at delivery. In PARROT-2 (Duhig/Hurrell 2024; 1,252 women), REVEALED REPEAT testing made no difference: the perinatal composite (stillbirth, early neonatal death or neonatal-unit admission) occurred in 31.2% versus 27.8% (p=0.18; the treatment made no difference), and routine repeat testing was not recommended. One positive strategy trial plus one null repeat-testing trial caps the stamp at POSSIBLE.

MeSH: Adult · Biomarkers/blood · Female · Humans · Placenta Growth Factor · Pre-Eclampsia/blood/diagnosis · Predictive Value of Tests · Pregnancy · Pregnancy Proteins/blood · Prospective Studies · ROC Curve · Sensitivity and Specificity · Vascular Endothelial Growth Factor Receptor-1/blood

Cards (4)

Card 1 — Zeisler 2016 (PROGNOSIS) — accuracy: sFlt-1/PlGF ratio ≤38 had a 99.3% negative predictive value for no pre-eclampsia within 1 week; a ratio above 38 predicted pre-eclampsia within 4 weeks with only 36.7% positive predictive value

Study: Prospective diagnostic-accuracy study (Zeisler 2016, PROGNOSIS)

Population: Women with singleton pregnancies and suspected pre-eclampsia at 24 weeks 0 days to 36 weeks 6 days of gestation in a prospective multicentre observational study: a development cohort of 500 women, in which the ratio cutoff of 38 was derived, and a validation cohort of a further 550 women.

Summary: Zeisler 2016 (PROGNOSIS) — accuracy: sFlt-1/PlGF ratio ≤38 had a 99.3% negative predictive value for no pre-eclampsia within 1 week; a ratio above 38 predicted pre-eclampsia within 4 weeks with only 36.7% positive predictive value

Result: In the validation cohort, an sFlt-1/PlGF ratio of 38 or lower had a negative predictive value of 99.3% (95% CI 97.9 to 99.9) for the absence of pre-eclampsia in the subsequent week, with 80.0% sensitivity (95% CI 51.9 to 95.7) and 78.3% specificity (95% CI 74.6 to 81.7). A ratio above 38 had a positive predictive value of 36.7% (95% CI 28.4 to 45.7) for a diagnosis of pre-eclampsia within 4 weeks, with 66.2% sensitivity and 83.1% specificity. These are accuracy figures: the test is a strong rule-out and a weak rule-in.

Watch out: Negative predictive value depends on how common pre-eclampsia is in the tested population — in these suspected-case cohorts about 99 of 100 women below the cutoff stayed free of pre-eclampsia for a week; the same cutoff performs differently where prevalence differs, and a high ratio alone diagnoses nothing (roughly 2 of 3 women above it did not develop pre-eclampsia within 4 weeks). The study was funded by the test's manufacturer, Roche Diagnostics.

Source: Zeisler H et al. Predictive Value of the sFlt-1:PlGF Ratio in Women with Suspected Preeclampsia. The New England Journal of Medicine. 2016. PMID: 26735990. Registry ID: none in the record. MeSH: Adult · Biomarkers/blood · Female · Humans · Placenta Growth Factor · Pre-Eclampsia/blood/diagnosis · Predictive Value of Tests · Pregnancy · Pregnancy Proteins/blood · Prospective Studies · ROC Curve · Sensitivity and Specificity · Vascular Endothelial Growth Factor Receptor-1/blood

Card 2 — Duhig 2019 (PARROT) — strategy: revealing PlGF results cut median time to diagnosis from 4.1 to 1.9 days and severe maternal adverse outcomes were 4% versus 5% (adjusted OR 0.32); perinatal outcomes did not differ (15% vs 14%)

Study: Stepped-wedge cluster-randomised trial (Duhig 2019, PARROT)

Population: 1,023 eligible women aged 18 years and older presenting with suspected pre-eclampsia between 20 weeks 0 days and 36 weeks 6 days of gestation with a live singleton fetus, in 11 UK maternity units (3,000–9,000 deliveries per year each); 573 women were analysed in the revealed-testing periods and 446 in the concealed-testing (usual care) periods, in a pragmatic stepped-wedge cluster-randomised design in which PlGF was measured in everyone but only revealed in the intervention phase, alongside a clinical management algorithm.

Summary: Duhig 2019 (PARROT) — strategy: revealing PlGF results cut median time to diagnosis from 4.1 to 1.9 days and severe maternal adverse outcomes were 4% versus 5% (adjusted OR 0.32); perinatal outcomes did not differ (15% vs 14%)

Result: Median time from presentation to documented pre-eclampsia diagnosis was 1.9 days with revealed testing versus 4.1 days with concealed testing (time ratio 0.36, 95% CI 0.15–0.87; p=0.027). Severe maternal adverse outcomes occurred in 22 of 573 women (4%) in the revealed group versus 24 of 447 (5%) in the concealed group (adjusted odds ratio 0.32, 95% CI 0.11–0.96; p=0.043) — an odds ratio, a relative measure, on small absolute numbers. There was no evidence of a difference in perinatal adverse outcomes (15% versus 14%) or in gestation at delivery (36.6 versus 36.8 weeks).

Watch out: The maternal-outcome signal rests on 46 events in a cluster trial whose primary outcome was time to diagnosis — a process outcome that revealing a test almost mechanically improves; the perinatal outcomes women and babies ultimately care about did not differ, and the stepped-wedge design is vulnerable to calendar-time trends.

Source: Duhig KE et al. Placental growth factor testing to assess women with suspected pre-eclampsia: a multicentre, pragmatic, stepped-wedge cluster-randomised controlled trial. The Lancet. 2019. PMID: 30948284. Registry ID: ISRCTN 16842031, from the record. MeSH: Adult · Algorithms · Female · Fetal Growth Retardation/diagnosis · Gestational Age · Humans · Hypertension/complications/diagnosis/epidemiology · Infant, Newborn · Outcome Assessment, Health Care · Perinatal Death · Placenta Growth Factor/blood · Pre-Eclampsia/diagnosis/epidemiology/metabolism/physiopathology · Pregnancy · Pregnancy Complications/epidemiology · Pregnancy Outcome/epidemiology · Proteinuria/complications/diagnosis/epidemiology

Estimate type: adjusted estimate, as stated in the card.

Card 3 — Hurrell 2024 (PARROT-2) — REPEAT testing NULL: revealed repeat PlGF testing did not improve the perinatal composite (31.2% vs 27.8%; p=0.18) (the treatment made no difference); routine repeat testing not recommended

Study: Randomised controlled trial (Hurrell 2024, PARROT-2)

Population: 1,252 pregnant women aged 18 years and older with suspected preterm pre-eclampsia between 22 weeks 0 days and 35 weeks 6 days of gestation, in 22 maternity units across England, Scotland and Wales, randomly assigned to revealed repeat PlGF-based testing (625 women, using a management algorithm and nationally recommended thresholds) or concealed repeat testing with usual care (627 women). The primary outcome was a perinatal composite of stillbirth, early neonatal death or neonatal unit admission.

Summary: Hurrell 2024 (PARROT-2) — REPEAT testing NULL: revealed repeat PlGF testing did not improve the perinatal composite (31.2% vs 27.8%; p=0.18) (the treatment made no difference); routine repeat testing not recommended

Result: There was no significant difference in the primary perinatal composite outcome: 195 of 625 women (31.2%) in the revealed repeat-testing group versus 174 of 626 (27.8%) in the concealed group (p=0.18; the treatment made no difference), with per-protocol results similar. Serious adverse events were few (four versus six) and all deemed unrelated to the intervention. The authors concluded that universal, routine repeat PlGF-based testing of everyone with suspected pre-eclampsia is not recommended in a high-income setting with a low prevalence of adverse outcomes.

Watch out: PARROT-2 tests repeat testing, not the first test: its null does not erase PARROT's faster-diagnosis result, but it does close the door on the natural 'test again later' extension — and its point estimate, if anything, favoured the concealed group, underlining that more testing is not automatically better care.

Source: Hurrell A et al. Repeat placental growth factor-based testing in women with suspected preterm pre-eclampsia (PARROT-2): a multicentre, parallel-group, superiority, randomised controlled trial. The Lancet. 2024. PMID: 38342128. Registry ID: ISRCTN 85912420, from the record. MeSH: Adult · Female · Humans · Infant, Newborn · Pregnancy · Parturition · Placenta Growth Factor · Pre-Eclampsia/diagnosis · Stillbirth/epidemiology

Card 4 — Synthesis: test once and reveal — a strong rule-out (NPV 99.3%) and a faster, possibly safer diagnostic pathway; test repeatedly — no benefit

Study: Synthesis

Population: The evidence chain: a 1,050-woman accuracy study (PROGNOSIS), a 1,023-woman cluster-randomised strategy trial of revealed versus concealed testing (PARROT), and a 1,252-woman randomised trial of revealed versus concealed repeat testing (PARROT-2), all in women with suspected preterm pre-eclampsia.

Summary: Synthesis: test once and reveal — a strong rule-out (NPV 99.3%) and a faster, possibly safer diagnostic pathway; test repeatedly — no benefit

Result: Accuracy and strategy answer different questions and are kept separate on this shelf. Accuracy: a ratio at or below 38 makes pre-eclampsia within a week very unlikely (99.3% negative predictive value), while a high ratio is a weak predictor (36.7% positive predictive value over 4 weeks). Strategy: revealing a first PlGF result with an algorithm halved time to diagnosis and was associated with fewer severe maternal adverse outcomes, without perinatal benefit; revealing repeat results changed nothing (the treatment made no difference).

Watch out: Adoption arguments often merge the accuracy headline with outcome claims the trials did not show: no trial here demonstrated fewer perinatal deaths or admissions from testing, and the maternal-outcome signal comes from one cluster trial with 46 events. The supported claim is narrower — faster, better-targeted assessment after a single test.

Source: Synthesis of Zeisler H et al. The New England Journal of Medicine. 2016 (PMID: 26735990); Duhig KE et al. The Lancet. 2019 (PMID: 30948284); Hurrell A et al. The Lancet. 2024 (PMID: 38342128).