Long-acting reversible contraception: levonorgestrel intrauterine system vs copper IUD

Shelf #659 · Women’s health

POSSIBLE

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How do the levonorgestrel intrauterine system and copper IUD compare on continuation, bleeding, and satisfaction in head-to-head randomised data?

Balance of the evidence

POSSIBLE: The one head-to-head randomised trial — 199 women living with HIV in Cape Town, South Africa (median age 31) — found the levonorgestrel intrauterine system did not increase genital or plasma HIV viral load versus the copper IUD over 24 months, while continuation favoured the levonorgestrel system (copper users had significantly more expulsions, 8% vs 1%, and far more elective discontinuations, adjusted hazard ratio 8.75, a relative figure) and haemoglobin rose more with the levonorgestrel system (+0.71 g/dL at 24 months). A single trial in a specific population caps the stamp at POSSIBLE, and its continuation and bleeding findings should not be generalised beyond that population without corroboration. Emergency contraception lives on Shelf #244 and is not re-carded here.

MeSH: Contraceptive Agents, Female/adverse effects,therapeutic use · HIV Infections/drug therapy,etiology · Intrauterine Devices, Copper/adverse effects · Levonorgestrel/adverse effects,therapeutic use · South Africa

Cards (2)

Card 1 — Todd 2020: in women living with HIV, the LNG-IUS matched the copper IUD on viral-load safety and won on continuation

Study: Double-masked, randomised, noninferiority trial (Cape Town, South Africa)

Population: 199 women living with HIV, aged 18–40, not pregnant or desiring pregnancy within 30 months, randomised to the levonorgestrel intrauterine system (101) or copper intrauterine device (98) within antiretroviral-therapy (ART) strata (71 non-ART, 134 ART-using women enrolled across the strata as reported); median age 31 years; 95% had one or more prior pregnancies.

Summary: Todd 2020: in women living with HIV, the LNG-IUS matched the copper IUD on viral-load safety and won on continuation.

Result: Proportions with detectable genital tract viral load did not differ between LNG-IUS and copper IUD at 6 months (adjusted odds ratio 0.78, 95% CI 0.44 to 1.38) or 24 months (1.03, 0.68 to 1.57); plasma viral load results were likewise non-significant in ART users and non-ART women. Overall intrauterine-contraception continuation was 78%; copper users had significantly higher expulsion (8% vs 1%, p=0.02) and elective discontinuation (adjusted hazard ratio 8.75, 3.08 to 24.8 — a relative figure; p<0.001). Of 39 serious adverse events, 7 were judged directly device-related (3 pelvic inflammatory disease cases and 4 pregnancies with a device in place, with no discernible trend by arm). Mean haemoglobin change favoured LNG-IUS at 6 months (+0.57 g/dL, 0.24 to 0.90) and 24 months (+0.71 g/dL, 0.47 to 0.95).

Watch out: Population-specific by design: women living with HIV in one South African setting, with the non-ART stratum under-recruited after ART guideline changes and 24-month data truncated for 17 women; a viral-load assay change mid-study may have introduced measurement discrepancy. Continuation and satisfaction findings in this population are hypothesis-confirming for, not proof in, the general contraceptive population.

Source: Todd CS et al. Safety and continued use of the levonorgestrel intrauterine system as compared with the copper intrauterine device among women living with HIV in South Africa: A randomized controlled trial. PLoS Med. 2020;17(5):e1003110. PMID: 32442189. Registry ID: ClinicalTrials.gov: NCT01721798, from the record's databank fields.

Estimate type: adjusted estimate, as stated in the card.

Card 2 — Synthesis: one rigorous head-to-head trial, in one population — LNG-IUS at least as acceptable, with less blood loss

Study: Synthesis

Population: Synthesis of the card above: Todd 2020 (199 women living with HIV, Cape Town).

Summary: One rigorous head-to-head trial, in one population — LNG-IUS at least as acceptable, with less blood loss: POSSIBLE.

Result: Within its population the trial answers the safety worry that motivated it (no viral-load increase with the hormonal device) and adds two practical findings in the LNG-IUS's favour: devices stayed in (continuation 78% overall, with copper users discontinuing electively far more often) and haemoglobin rose instead of falling (+0.71 g/dL by 24 months), consistent with lighter bleeding on the hormonal system. Because the shelf rests on this single trial, every number here is stamped POSSIBLE, and the general-population version of this question remains open in the randomised record. Emergency contraception (Shelf #244) is a different question and stays home there.

Watch out: Do not present the continuation hazard ratio (8.75) without its population attached; elective discontinuation is behaviour- and context-dependent and will differ where copper-IUD counselling and follow-up differ.

Source: Synthesis of Todd CS et al. PLoS Med. 2020;17(5):e1003110. PMID: 32442189. Registry ID as on the individual card.