Intrathecal drug-delivery system for refractory cancer pain (single randomised trial)

Shelf #6609 · Cancer

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2002–2005.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with refractory cancer pain despite systemic opioids, does an implantable intrathecal drug-delivery system improve pain control and reduce drug toxicity versus comprehensive medical management alone? (Single-trial shelf: one randomised trial carries this question.)

Balance of the evidence

POSSIBLE — a single-trial shelf, labelled as such: one randomised trial (Smith 2002, 202 patients enrolled) carries this question, and a single trial caps the stamp at POSSIBLE however positive its result. In that trial, clinical success (at least 20% pain reduction, or equal pain with at least 20% less toxicity) at 4 weeks was achieved by 84.5% of intrathecal drug-delivery patients versus 70.8% on comprehensive medical management alone (P=.05); success on both pain and toxicity together was 57.7% versus 37.5% (P=.02). Toxicity scores fell 50% with the device versus 17% without (P=.004), driven by fatigue and depressed consciousness, and 6-month survival was 53.9% versus 37.2% (P=.06) — a non-significant difference in a trial not powered for survival, reported here as the authors reported it, not as a survival claim. A planned crossover analysis (30 patients whose medical management had failed) found pain down 27% and toxicity down 51% after implant, consistent with the randomised result but uncontrolled. No second randomised trial exists in this evidence base; device harms, cost and the need for surgical implantation and refills sit outside the trial's 4-week primary endpoint.

MeSH: Analgesics, Opioid/administration & dosage · Female · Humans · Infusion Pumps, Implantable · Linear Models · Male · Middle Aged · Neoplasms/complications · Pain/drug therapy,etiology · Pain Management · Pain Measurement · Prospective Studies · Statistics, Nonparametric · Survival Analysis · Treatment Outcome · Aged · Cohort Studies · Longitudinal Studies · Neoplasms/complications,physiopathology · Intractable Pain/drug therapy,etiology · Palliative Care

Cards (4)

Card 1 — Smith 2002 (the single randomised trial): clinical success in 84.5% with intrathecal delivery versus 70.8% with medical management; toxicity scores halved with the device

Study: Multicentre randomised clinical trial (implantable intrathecal drug-delivery system plus comprehensive medical management versus comprehensive medical management alone)

Population: 202 patients with refractory cancer pain (visual analogue pain scores of 5 or more on a 0–10 scale despite systemic therapy) enrolled; the 4-week primary analysis covers 71 device and 72 medical-management patients. Entry required unrelieved pain despite comprehensive medical management.

Summary: Smith 2002 (the single randomised trial): clinical success in 84.5% with intrathecal delivery versus 70.8% with medical management; toxicity scores halved with the device

Result: Clinical success (at least 20% reduction in pain score, or equal score with at least 20% reduction in toxicity) was achieved by 60 of 71 device patients (84.5%) versus 51 of 72 medical patients (70.8%) (P=.05); at least 20% reduction in both pain and toxicity occurred in 57.7% versus 37.5% (P=.02). Mean pain scores fell 52% with the device (7.57 to 3.67) versus 39% without (7.81 to 4.76) (P=.055); mean toxicity scores fell 50% (7.22 to 3.59) versus 17% (6.36 to 5.27) (P=.004), with significant reductions in fatigue and depressed level of consciousness. Six-month survival was 53.9% versus 37.2% (P=.06).

Watch out: One trial, unblinded by necessity, with a borderline primary P value (.05), substantial attrition by 4 weeks (143 of 202 analysed) in a population with advanced cancer, and a survival difference that did not reach significance — the result is genuinely positive and genuinely single.

Source: Smith TJ et al. Randomized clinical trial of an implantable drug delivery system compared with comprehensive medical management for refractory cancer pain: impact on pain, drug-related toxicity, and survival. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 2002. PMID: 12351602. Registry ID: none in the record's databank fields. MeSH: Analgesics, Opioid/administration & dosage · Female · Humans · Infusion Pumps, Implantable · Linear Models · Male · Middle Aged · Neoplasms/complications · Pain/drug therapy,etiology · Pain Management · Pain Measurement · Prospective Studies · Statistics, Nonparametric · Survival Analysis · Treatment Outcome

Card 2 — Crossover analysis: in 30 patients whose expert medical management had failed, pain fell 27% and toxicity 51% after crossing over to intrathecal delivery

Study: Planned prospective longitudinal analysis within the Smith randomised trial (patients crossing from medical management to device by 6 months)

Population: 30 of 99 medical-management patients (30%) for whom comprehensive medical management failed — pain scores of 5 or more despite a month of opioids at 320 mg or more morphine-equivalent plus adjunct drugs — who crossed over to an implantable intrathecal programmable pump with opioids and local anaesthetics.

Summary: Crossover analysis: in 30 patients whose expert medical management had failed, pain fell 27% and toxicity 51% after crossing over to intrathecal delivery

Result: Clinical success was achieved after crossover, with pain scores significantly reduced by 27% (P=0.011) and drug toxicity scores by 51% (P<.0001). Median survival after implant was 103 days, similar to patients implanted as part of the initial randomisation; the authors note a 3-month survival may be long enough for the implant to be cost-effective.

Watch out: Uncontrolled before–after data in the most refractory subgroup — regression to the mean and survivor selection both favour the device, so this card supports consistency, not proof.

Source: Smith TJ et al. Implantable drug delivery systems (IDDS) after failure of comprehensive medical management (CMM) can palliate symptoms in the most refractory cancer pain patients. Journal of palliative medicine. 2005. PMID: 16128647. Registry ID: none in the record's databank fields. MeSH: Aged · Cohort Studies · Female · Humans · Infusion Pumps, Implantable · Longitudinal Studies · Male · Middle Aged · Neoplasms/complications,physiopathology · Intractable Pain/drug therapy,etiology · Palliative Care · Prospective Studies

Card 3 — Smith & Coyne evidence review: the randomised trial is the only controlled evidence; the 1980–2003 cohort literature showed pain relief without standardised assessment or control groups

Study: Evidence review of implantable drug-delivery systems for refractory cancer pain (cohort reports 1980–2003 plus the randomised trial)

Population: Published cohort reports from 1980 through 2003 and the 202-patient randomised trial population with unrelieved pain (scores of 5 or more) despite conventional management. This record carries no MeSH terms in PubMed (noted on its source line).

Summary: Smith & Coyne evidence review: the randomised trial is the only controlled evidence; the 1980–2003 cohort literature showed pain relief without standardised assessment or control groups

Result: The non-randomised trials all showed pain relief with acceptable complication rates but often lacked standardised assessment, control groups and multi-institution design. In the randomised trial, clinical success was 84.5% with the device versus 70.5% with medical management (P<.05), pain scores fell 52% versus 39% (P=0.057) and toxicity scores fell 52% versus 19% (P=0.01) by the review's figures, with all individual toxicities improved more by the device, especially fatigue and depressed consciousness.

Watch out: A review co-authored by the trial's lead investigator — it organises the evidence honestly (including the weakness of the cohort base) but is not an independent appraisal, and its slightly different percentages reflect its own rounding of the trial data.

Source: Smith TJ et al. What is the evidence for implantable drug delivery systems for refractory cancer pain? Supportive cancer therapy. 2004. PMID: 18628140. Registry ID: none in the record's databank fields. MeSH: not captured from the record

Card 4 — Synthesis: one randomised trial shows better pain-plus-toxicity success with intrathecal delivery — POSSIBLE, single-trial shelf, exactly as labelled

Study: Synthesis

Population: Synthesis of the Smith 2002 randomised trial (202 enrolled, 143 in the 4-week primary analysis), its planned crossover analysis (30 patients) and an evidence review of the 1980–2003 cohort literature.

Summary: Synthesis: one randomised trial shows better pain-plus-toxicity success with intrathecal delivery — POSSIBLE, single-trial shelf, exactly as labelled

Result: The randomised comparison favours the device on the combined pain-and-toxicity endpoint (84.5% versus 70.8%), on toxicity reduction (50% versus 17%) and on achieving both pain and toxicity success (57.7% versus 37.5%); the crossover experience is consistent. With one trial and no replication, the stamp is POSSIBLE and the shelf is labelled single-trial wherever it is summarised.

Watch out: Implantation is surgery in patients with advanced cancer, with device, infection and refill burdens the 4-week endpoint does not capture; the near-significant survival difference (P=.06) must not be quoted as a survival benefit.

Source: Synthesis of Smith TJ et al. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 2002 (PMID: 12351602); Smith TJ et al. Journal of palliative medicine. 2005 (PMID: 16128647); Smith TJ et al. Supportive cancer therapy. 2004 (PMID: 18628140).