PHYSIOLOGY — the Guyton venous-return curve in humans: what is measured at the bedside is a model-derived mean-systemic-filling-pressure ANALOGUE (about 15–21 mmHg by method) in postoperative and ICU patients — not a directly measured Guyton curve, and not in healthy volunteers

Shelf #6631 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — EMERGING — the human Pmsf is a model-derived analogue, not a direct measurement: inspiratory-hold ~20.9 mmHg, arm equilibrium ~19.8 mmHg and model analogue ~14.9 mmHg in the same postoperative patients (methods disagree by ~6 mmHg); all human data are from postoperative/ICU patients, none from healthy volunteers

Stamped: 2026-11-28.

Evidence published: 1991–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In humans, can the Guyton venous-return curve be measured — what is the analogue of mean systemic filling pressure at zero flow (the Pmsf analogue), how close does it sit to right atrial pressure at rest, and how do volume loading and vasopressors move it?

Balance of the evidence

PHYSIOLOGY — EMERGING. Textbook framing (Guyton & Hall): venous return is driven by the gradient between mean systemic filling pressure (Pmsf) — the equilibrated pressure in the systemic circulation at zero flow — and right atrial pressure, and the venous-return curve plots flow against right atrial pressure with its zero-flow intercept at Pmsf. In humans that intercept cannot be measured directly in an intact circulation; what the human literature measures is an ANALOGUE, and this pack says so plainly, as required. Parkin & Wright (PMID: 1919281) proposed deriving a mean systemic filling pressure analogue from cardiac output, right atrial pressure and arterial pressure by modelling a notional regional circulation at stop-flow — a model-derived estimate from the start, offered as a quantitative link between volume state and therapy. Maas JJ et al. (PMID: 22584797), in 11 mechanically ventilated postoperative cardiac-surgery patients, compared three estimates across supine, head-up tilt and 500 mL colloid loading: inspiratory-hold Pmsf averaged 20.9 ± 5.6 mmHg, arm equilibrium pressure 19.8 ± 5.7 mmHg, and the model analogue (Pmsa) 14.9 ± 4.0 mmHg — the analogue ran about 6 mmHg below the hold estimate (bias −6.0 ± 3.1 mmHg), while changes with tilt and loading were directionally concordant across methods. In a companion study (PMID: 22763909; 15 postoperative patients), systemic vascular compliance was linear at 64.3 ± 32.7 mL/mmHg and stressed volume was estimated at 1,265 ± 541 mL (28.5% of predicted blood volume) by extrapolating the Pmsf–volume curve to zero pressure. Guérin L, Teboul JL, Persichini R et al. (PMID: 26597901), in 30 patients with acute circulatory failure, built venous-return curves from cardiac index–central venous pressure pairs during ventilatory occlusions: in fluid responders, passive leg raising raised Psm from 25 ± 13 to 31 ± 13 mmHg and widened the Psm–CVP gradient by 20 ± 30%, while resistance to venous return did not change — volume recruitment moves the intercept, not the slope resistance, in that manoeuvre. Every measurement here is in postoperative or ICU PATIENTS, not healthy volunteers, and every 'Pmsf' value is method-dependent (hold, arm stop-flow, or model analogue disagree by several mmHg in the same patients). The honest statement is: the Guyton framework organises these bedside estimates coherently, but no study in this pack measured a Guyton venous-return curve directly in a healthy human.

MeSH: Blood Circulation/physiology · Heart/physiology · Humans · Models, Cardiovascular · Vascular Resistance/physiology · Aged · Aged, 80 and over · Blood Pressure/physiology · Cardiac Output · Cardiac Surgical Procedures · Coronary Artery Disease/pathology · Female · Hemodynamics · Male · Middle Aged · Postoperative Period · Statistics, Nonparametric · Time Factors · Venous Pressure · Blood Pressure Determination/methods · Heart Function Tests/methods · Inhalation/physiology · Intensive Care Units · Point-of-Care Systems · Respiration, Artificial/methods · Stroke Volume/physiology · Fluid Therapy/methods · Hemodynamics/physiology · Leg · Posture/physiology · Shock/physiopathology,therapy · Treatment Outcome · Veins/physiopathology

Cards (5)

Card 1 — Parkin & Wright 1991 (analogue programme, human circulation control studies; N not documented in the record): the Pmsf analogue is DERIVED from a notional stop-flow regional circulation — a model estimate, proposed as the quantitative link between volume state and therapy

Study: Physiology methods and closed-loop control study (Parkin & Wright 1991)

Population: Human circulatory-control studies reported by the Parkin programme, in which mean blood pressure, right atrial pressure and cardiac output were simultaneously controlled within desired tolerances using state-based control; the record does not document a participant N, and none is claimed.

Summary: Parkin & Wright 1991 (analogue programme, human circulation control studies; N not documented in the record): the Pmsf analogue is DERIVED from a notional stop-flow regional circulation — a model estimate, proposed as the quantitative link between volume state and therapy

Result: The authors propose mean systemic filling pressure as a parsimonious description of volume state and describe a method of deriving a mean systemic filling pressure analogue based on stopping the flow in a notional regional systemic circulation, with the ratio (PM − PRA)/PM offered as a global measure of cardioactive drug effect. The analogue is, by construction, computed from measured pressures and flow — not a pressure ever read off a stopped human circulation.

Watch out: N not documented in the fetched record — labelled plainly per the physiology rule. This is the conceptual source of the 'analogue' language the whole pack depends on; it is a methods paper, and its numbers are control tolerances, not population values.

Source: Parkin WG et al. Three dimensional closed loop control of the human circulation. International journal of clinical monitoring and computing. 1991. PMID: 1919281. Registry ID: none in the record. MeSH: Blood Circulation/physiology · Heart/physiology · Humans · Models, Cardiovascular · Vascular Resistance/physiology

Card 2 — Maas 2012a (postoperative cardiac-surgery patients, N=11): three Pmsf estimates in the same patients — inspiratory-hold 20.9 ± 5.6, arm equilibrium 19.8 ± 5.7, model analogue 14.9 ± 4.0 mmHg; analogue biased −6.0 mmHg below hold

Study: Bedside methods-comparison physiology study in ICU patients (Maas 2012)

Population: 11 mechanically ventilated postoperative cardiac surgery patients, studied supine, at 30° head-up tilt, and after 500 mL colloid loading, with inspiratory-hold manoeuvres, upper-arm stop-flow occlusion (30 seconds) and a Guytonian model analogue computed at each state.

Summary: Maas 2012a (postoperative cardiac-surgery patients, N=11): three Pmsf estimates in the same patients — inspiratory-hold 20.9 ± 5.6, arm equilibrium 19.8 ± 5.7, model analogue 14.9 ± 4.0 mmHg; analogue biased −6.0 mmHg below hold

Result: Mean values across states: Pmsf (hold) 20.9 ± 5.6 mmHg, arm equilibrium pressure 19.8 ± 5.7 mmHg, model analogue 14.9 ± 4.0 mmHg. Arm pressure and hold Pmsf were interchangeable (bias −1.0 ± 3.08 mmHg; limits of agreement −7.3 to 5.2); the model analogue differed significantly (bias −6.0 ± 3.1 mmHg; limits −12.4 to 0.3). Changes in all three tracked head-up tilt and volume loading in the same direction.

Watch out: N=11 patients, printed plainly — postoperative, ventilated, vasoactively supported patients, not healthy volunteers. The ~6 mmHg method gap in the same patients at the same moment is the single most important number in this pack: 'the Pmsf' in humans is method-defined.

Source: Maas JJ et al. Estimation of mean systemic filling pressure in postoperative cardiac surgery patients with three methods. Intensive care medicine. 2012. PMID: 22584797. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Blood Pressure/physiology · Cardiac Output · Cardiac Surgical Procedures · Coronary Artery Disease/pathology · Female · Hemodynamics · Humans · Male · Middle Aged · Postoperative Period · Statistics, Nonparametric · Time Factors · Venous Pressure

Card 3 — Maas 2012b (postoperative ICU patients, N=15): systemic vascular compliance 64.3 ± 32.7 mL/mmHg (linear); stressed volume estimated 1,265 ± 541 mL (28.5% of predicted blood volume) by extrapolating the Pmsf–volume curve to zero

Study: Bedside physiology study with sequential volume loading (Maas 2012)

Population: 15 mechanically ventilated postoperative cardiac surgery patients in intensive care, undergoing inspiratory holds and arm stop-flow manoeuvres during normovolaemia and after each of 10 sequential 50-mL colloid boluses (500 mL total), with cardiac function and compliance curves constructed at the bedside.

Summary: Maas 2012b (postoperative ICU patients, N=15): systemic vascular compliance 64.3 ± 32.7 mL/mmHg (linear); stressed volume estimated 1,265 ± 541 mL (28.5% of predicted blood volume) by extrapolating the Pmsf–volume curve to zero

Result: Pmsf by hold and by arm were closely correlated. Systemic vascular compliance was linear at 64.3 ± 32.7 mL/mmHg (0.97 ± 0.49 mL·mmHg⁻¹·kg⁻¹ predicted body weight). Stressed volume, from extrapolating the Pmsf–volume curve to its zero-pressure intercept, was 1,265 ± 541 mL, or 28.5% ± 15% of predicted total blood volume. Cardiac function curves were steep in volume-responsive patients and flat in the rest.

Watch out: Stressed volume here is an extrapolation of a fitted line to zero pressure — two modelling steps removed from any measurement. N=15 patients, printed plainly; again a postoperative ICU population under mechanical ventilation.

Source: Maas JJ et al. Bedside assessment of total systemic vascular compliance, stressed volume, and cardiac function curves in intensive care unit patients. Anesthesia and analgesia. 2012. PMID: 22763909. Registry ID: none in the record. MeSH: Aged · Blood Pressure/physiology · Blood Pressure Determination/methods · Female · Heart Function Tests/methods · Humans · Inhalation/physiology · Intensive Care Units · Male · Middle Aged · Point-of-Care Systems · Respiration, Artificial/methods · Stroke Volume/physiology · Vascular Resistance/physiology

Card 4 — Guérin/Persichini 2015 (acute circulatory failure, N=30): leg raising raised Psm from 25 ± 13 to 31 ± 13 mmHg in fluid responders and widened the Psm–CVP gradient by 20 ± 30%, with no change in resistance to venous return

Study: Human venous-return-curve physiology study in shock (Guérin, Teboul & Persichini 2015)

Population: 30 patients with acute circulatory failure in whom venous-return curves were constructed as the regression line between cardiac index and central venous pressure pairs measured during end-inspiratory and end-expiratory ventilatory occlusions, at baseline, during passive leg raising and after fluid infusion; fluid responders (n=15) were those whose cardiac index rose more than 15% with infusion.

Summary: Guérin/Persichini 2015 (acute circulatory failure, N=30): leg raising raised Psm from 25 ± 13 to 31 ± 13 mmHg in fluid responders and widened the Psm–CVP gradient by 20 ± 30%, with no change in resistance to venous return

Result: In fluid responders, passive leg raising significantly increased central venous pressure (7 ± 3 to 9 ± 4 mmHg) and mean systemic pressure (25 ± 13 to 31 ± 13 mmHg), and the Psm–CVP gradient rose by 20 ± 30%, while resistance to venous return did not change significantly. In non-responders, Psm and CVP rose but the gradient did not. Fluid infusion produced the same pattern as leg raising.

Watch out: These Psm values (25–31 mmHg) are higher than the Maas postoperative estimates — different population (shock), different construction (occlusion-pair regression). That spread across methods and populations is itself the finding to carry away; there is no single human 'Pmsf number' this pack can honestly print as normal.

Source: Guérin L et al. Effects of passive leg raising and volume expansion on mean systemic pressure and venous return in shock in humans. Critical care (London, England). 2015. PMID: 26597901. Registry ID: none in the record. MeSH: Aged · Blood Circulation/physiology · Blood Pressure/physiology · Female · Fluid Therapy/methods · Hemodynamics/physiology · Humans · Leg · Male · Middle Aged · Posture/physiology · Shock/physiopathology,therapy · Treatment Outcome · Veins/physiopathology

Card 5 — Synthesis: a coherent framework, an analogue measurement — EMERGING, in patients only, with method spread of several mmHg

Study: Synthesis

Population: Four primary human studies: the Parkin & Lean analogue programme's founding methods paper (N not documented), two Maas bedside studies (N=11 and N=15 postoperative patients) and the Guérin/Teboul/Persichini occlusion-curve study (N=30 patients in circulatory failure), framed by Guyton & Hall as textbook background only.

Summary: Synthesis: a coherent framework, an analogue measurement — EMERGING, in patients only, with method spread of several mmHg

Result: Bedside Pmsf estimates in patients sit roughly between 15 and 31 mmHg depending on method and population; volume loading and leg raising move the estimated intercept upward and widen the gradient to right atrial pressure in responders, without changing resistance to venous return. PHYSIOLOGY — EMERGING, Tier C: the Guyton construction organises real human measurements, but the quantity is a model-derived analogue, the methods disagree by ~6 mmHg head-to-head, and no healthy-volunteer measurement exists in this base.

Watch out: This pack must not be cited as 'the measured human Guyton curve': no card measured venous return at zero flow in an intact healthy human, because that measurement cannot be made. The piglet validation study behind one pulse-contour method (Maas 2011, PMID: 21830048) was refused as a card under the no-animal-cards rule for physiology packs and is noted here only as a refusal.

Source: Synthesis of Parkin WG et al. International journal of clinical monitoring and computing. 1991 (PMID: 1919281); Maas JJ et al. Intensive care medicine. 2012 (PMID: 22584797); Maas JJ et al. Anesthesia and analgesia. 2012 (PMID: 22763909); Guérin L et al. Critical care (London, England). 2015 (PMID: 26597901). Textbook framing: Guyton & Hall.