SourceMed · Shelf #6688 in the ask interface
Anaesthesia-induced atelectasis: within 5 minutes of induction, dependent lung collapses in nearly everyone — and the size of the collapse tracks the shunt (r = 0.93–0.99)
Shelf #6688 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1985–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients under general anaesthesia, what is the physiological basis, extent and time course of anaesthesia-induced atelectasis and the resulting shunt?
Balance of the evidence
Framing (textbook account, Guyton & Hall Textbook of Medical Physiology and Ganong's Review of Medical Physiology — respiratory mechanics and ventilation-perfusion matching, cited as framing, not as evidence cards): induction of general anaesthesia drops functional residual capacity, the dependent lung is compressed, and collapsed but perfused alveoli create shunt. The Uppsala human CT programme measured every element of that account. The densities appear within 5 minutes of induction in all 20 patients studied, occupy about 4.8% of the transverse lung area in the most caudal slice, and do not grow over the next 20 minutes (PMID 3885791). Their extent correlates with shunt at r=0.93 and with impaired arterial oxygenation at r=0.99 (PMID 3085429); shunt after 15 minutes of anaesthesia ranged from 1% to 17% of cardiac output (PMID 3813078). Pooled CT data in 243 subjects found atelectasis in 90% of anaesthetised patients, larger with 100% inspired oxygen than with 30–50% (12.8 vs 8.1 cm2) (PMID 31918847). PHYSIOLOGY — ESTABLISHED: a single research group's classic programme, replicated internally across four decades of human studies and concordant with the textbook account; no animal study is carded (animal work appears nowhere in this pack's evidence).
MeSH: ['Pulmonary Atelectasis', 'Anesthesia, General', 'Pulmonary Gas Exchange', 'Tomography, X-Ray Computed', 'Humans']
Cards (5)
Card 1 — Brismar 1985: within 5 minutes of induction, every one of 20 patients developed dependent lung densities — 4.8% of the caudal lung area — and PEEP abolished them
Study: Primary human study — CT before/after induction (Brismar 1985)
Population: 20 patients (aged 23–76) studied by computed tomography before and after induction of general anaesthesia with muscular relaxation, plus 4 subjects studied awake over a longer period (N = 20 anaesthetised, printed plainly — a classic small physiology study).
Summary: Brismar 1985: within 5 minutes of induction, every one of 20 patients developed dependent lung densities — 4.8% of the caudal lung area — and PEEP abolished them
Result: No lung-tissue abnormality was present before anaesthesia. Within 5 minutes of induction, all subjects developed crest-shaped densities of increased density in the dependent regions of both lungs: largest in the most caudal segment (4.8 ± 0.8% of the transverse lung area, mean ± SE), smaller cephalad (3.4 ± 0.7%). The densities did not increase over a further 20 minutes and were not affected by inspired oxygen fraction. Moving to the lateral position cleared them from the non-dependent lung; PEEP of 10 cmH2O eliminated or reduced them. The 4 awake subjects showed no densities after 90 minutes supine. The authors proposed these densities are atelectasis formed by compression of lung tissue rather than by gas resorption.
Watch out: N = 20, and the identification of the densities as atelectasis was, in 1985, a proposal — the title says so. The two following cards are the same programme's tests of that proposal against gas exchange. Compression vs absorption as the mechanism is revisited by the 2020 pooled data (card 4): high inspired oxygen enlarged the atelectasis, which pure compression would not predict.
Source: Brismar B et al. Pulmonary densities during anesthesia with muscular relaxation — a proposal of atelectasis. Anesthesiology. 1985. PMID: 3885791. Registry ID: none in the record. MeSH: Adult · Aged · Anesthesia, General/adverse effects* · Closing Volume · Contrast Media · Female · Humans · Lung/diagnostic imaging* · Male · Middle Aged · Neuromuscular Blocking Agents/adverse effects* · Oxygen/administration & dosage · Pancuronium/adverse effects · Positive-Pressure Respiration · Posture · Pulmonary Atelectasis/diagnostic imaging/etiology*/prevention & control · Thiopental/adverse effects · Tomography, X-Ray Computed
Card 2 — Hedenstierna 1986: the bigger the atelectasis, the bigger the shunt — correlation r = 0.93 with shunt and r = 0.99 with oxygenation impairment (n=8)
Study: Primary human study — CT plus inert-gas elimination (Hedenstierna 1986)
Population: 8 essentially lung-healthy patients (N = 8, printed plainly — sub-10 N labelled per the physiology floor rule) studied awake and during halothane anaesthesia with mechanical ventilation; gas exchange by multiple inert gas elimination and blood gases, atelectasis by CT.
Summary: Hedenstierna 1986: the bigger the atelectasis, the bigger the shunt — correlation r = 0.93 with shunt and r = 0.99 with oxygenation impairment (n=8)
Result: Awake, ventilation and perfusion were well matched in most patients and no patient had CT signs of atelectasis. After 15 minutes of anaesthesia, shunt had appeared in all patients, ranging from 1% (unchanged from awake, in two patients) to 17% of cardiac output; the major ventilation-perfusion mode widened. Dependent densities (interpreted as atelectasis) appeared in 6 of 8 patients, and their extent correlated significantly with shunt magnitude (r=0.93, P<0.01) and with impairment of arterial oxygenation (r=0.99, P<0.001). The authors concluded atelectasis is the major or sole cause of impaired gas exchange in the lung-healthy anaesthetised subject.
Watch out: N = 8: correlations of 0.93–0.99 in 8 subjects are striking but rest on few points, and correlation inside one programme's measurements is not independent proof of causation. Halothane-era anaesthesia; the direction of the physiology, not the exact shunt range, is what later work confirms.
Source: Hedenstierna G et al. Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysis. Acta Anaesthesiologica Scandinavica. 1986. PMID: 3085429. Registry ID: none in the record. MeSH: Adult · Anesthesia, General/adverse effects* · Carbon Dioxide/blood · Female · Hemodynamics · Humans · Lung/diagnostic imaging · Male · Middle Aged · Oxygen/blood · Pancuronium · Pulmonary Atelectasis/etiology*/physiopathology · Pulmonary Gas Exchange* · Respiration · Respiratory Function Tests · Tomography, X-Ray Computed · Ventilation-Perfusion Ratio
Card 3 — Tokics 1987: densities in 11 of 13 patients and shunt in all after 15 minutes — present even with spontaneous breathing, worse after paralysis
Study: Primary human study — breathing mode and paralysis (Tokics 1987)
Population: 13 supine patients with no apparent lung disease (N = 13), studied awake and during halothane anaesthesia by CT and multiple inert gas elimination; 5 were also studied during spontaneous breathing under anaesthesia before muscle paralysis.
Summary: Tokics 1987: densities in 11 of 13 patients and shunt in all after 15 minutes — present even with spontaneous breathing, worse after paralysis
Result: Awake, no patient had clear CT atelectasis. After 15 minutes of anaesthesia with mechanical ventilation, 11 of 13 had dependent densities and all had a shunt (1% to 17% of cardiac output); shunt magnitude correlated with density size (r=0.84, P<0.001). During spontaneous breathing under anaesthesia, densities and shunt were both present but small (1.8% and 3.7% respectively, as reported); both increased after muscle paralysis. PEEP reduced the density area in all patients but did not consistently reduce the shunt.
Watch out: The PEEP dissociation — less atelectasis on CT without a consistent fall in shunt — is a standing caution against treating the CT picture and the gas-exchange defect as interchangeable measures. N = 13, single programme.
Source: Tokics L et al. Lung collapse and gas exchange during general anesthesia: effects of spontaneous breathing, muscle paralysis, and positive end-expiratory pressure. Anesthesiology. 1987. PMID: 3813078. Registry ID: none in the record. MeSH: Adult · Anesthesia, General* · Cardiac Output · Female · Humans · Male · Middle Aged · Paralysis/therapy · Pulmonary Atelectasis/etiology/therapy* · Pulmonary Gas Exchange* · Respiration · Respiration, Artificial · Tomography, X-Ray Computed · Ventilation-Perfusion Ratio
Card 4 — Hedenstierna 2020: pooled CT data in 243 subjects — atelectasis in 90% under anaesthesia, larger on 100% oxygen (12.8 vs 8.1 cm2)
Study: Primary human study — pooled CT analysis, 243 subjects (Hedenstierna 2020)
Population: Pooled primary analysis of previously published CT studies: 243 subjects aged 18–78, BMI 18–52 kg/m2, without clinical cardiopulmonary disease, scanned awake and during anaesthesia before surgery after preoxygenation with inspired oxygen fraction above 0.8, then ventilated with FIO2 0.3 or higher and no PEEP.
Summary: Hedenstierna 2020: pooled CT data in 243 subjects — atelectasis in 90% under anaesthesia, larger on 100% oxygen (12.8 vs 8.1 cm2)
Result: Atelectasis of up to 39 cm2 in a transverse scan near the diaphragm was seen in 90% of subjects during anaesthesia. Atelectasis area rose with age to about 50 years and fell beyond it, and rose with BMI up to 30 kg/m2 with no further increase in obesity — greater age and obesity limited, rather than increased, atelectasis formation. Subjects receiving FIO2 1.0 had more atelectasis than those on FIO2 0.3–0.5 (12.8 vs 8.1 cm2, P<0.001), supporting an absorption component alongside compression. Arterial oxygen fell with both age and BMI.
Watch out: A pooled re-analysis of the same research programme's earlier studies (publication type includes meta-analysis) — it extends the classic findings to age, BMI and oxygen fraction but is not an independent group's replication. Ventilation here used no PEEP, so areas are larger than in modern PEEP-managed practice.
Source: Hedenstierna G et al. Higher age and obesity limit atelectasis formation during anaesthesia: an analysis of computed tomography data in 243 subjects. British Journal of Anaesthesia. 2020. PMID: 31918847. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Distribution · Age Factors · Aged · Anesthesia, General/adverse effects*/methods · Body Mass Index · Female · Humans · Male · Middle Aged · Obesity/complications*/physiopathology · Postoperative Complications/diagnostic imaging/etiology/prevention & control* · Pulmonary Atelectasis/diagnostic imaging/etiology*/physiopathology/prevention & control · Pulmonary Gas Exchange/physiology · Respiration, Artificial/methods · Smoking/adverse effects · Tidal Volume/physiology · Tomography, X-Ray Computed · Young Adult
Card 5 — Synthesis: anaesthesia collapses dependent lung within minutes in almost everyone, and the collapse — not a primary perfusion change — accounts for the shunt
Study: Synthesis
Population: Four primary human CT/gas-exchange studies from the Uppsala programme: 20 patients (1985), 8 patients (1986), 13 patients (1987), and a pooled 243 subjects (2020).
Summary: Synthesis: anaesthesia collapses dependent lung within minutes in almost everyone, and the collapse — not a primary perfusion change — accounts for the shunt
Result: Time course: densities appear within 5 minutes of induction and do not grow over the next 20 minutes. Extent: about 3–5% of transverse lung area on single slices, up to 39 cm2 near the diaphragm in pooled data, present in 90% of anaesthetised subjects. Mechanism: compression of dependent lung (posture-dependent, PEEP-reversible) with an absorption contribution at high inspired oxygen. Consequence: shunt of 1–17% of cardiac output whose size tracks atelectasis extent (r=0.84–0.99 across studies). Textbook framing: Guyton & Hall and Ganong (ventilation-perfusion matching and the effects of anaesthesia on lung volumes) — cited as framing, not as evidence cards. PHYSIOLOGY — ESTABLISHED.
Watch out: Single-programme provenance is the honest caveat: one research group generated nearly all the primary human data, using halothane-era techniques in the classic studies. The findings are textbook-settled and internally replicated over 35 years, which is why the stamp is ESTABLISHED — but independent-group CT replication is thin, and modern anaesthetic practice (PEEP, recruitment, lower FIO2) modifies the magnitudes.
Source: Synthesis of Brismar B et al. Anesthesiology. 1985 (PMID: 3885791); Hedenstierna G et al. Acta Anaesthesiologica Scandinavica. 1986 (PMID: 3085429); Tokics L et al. Anesthesiology. 1987 (PMID: 3813078); Hedenstierna G et al. British Journal of Anaesthesia. 2020 (PMID: 31918847).