SourceMed · Shelf #6721 in the ask interface

Lumen-apposing metal stents vs plastic stents for pancreatic walled-off necrosis

Shelf #6721 · Liver & gut

SPLIT — randomised trials disagree and the pooled result shows no advantage in treatment success: LAMS shorten procedures, and their early safety disadvantage disappeared after protocols changed to 3-week imaging and early removal

Stamped: 2026-11-28.

Evidence published: 2019–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with pancreatic walled-off necrosis undergoing endoscopic drainage, do lumen-apposing metal stents (LAMS), compared with double-pigtail plastic stents, improve treatment success and reduce adverse events?

Balance of the evidence

The randomised record is split, and the honest summary is 'no consistent advantage'. Bang et al. (n = 60) found non-superiority of LAMS with MORE stent-related adverse events (32.3% vs 6.9%); PROMETHEUS (n = 64) found similar clinical success and similar stent adverse events; a 2024 multicentre trial in infected walled-off necrosis (n = 46) found no difference in necrosectomy number but higher 8-week clinical success with a novel electrocautery-enhanced LAMS; and a 2025 meta-analysis of seven RCTs found no difference in treatment success, bleeding, necrosectomy, reintervention, hospitalisation or mortality — only shorter procedure time with metal stents. The safety story is protocol-dependent, and it changed practice mid-programme: in Bang's trial, significant LAMS adverse events (including bleeding) clustered at ≥3 weeks, an interim audit changed the protocol to CT imaging at 3 weeks with LAMS removal if the collection had resolved, and after that amendment the adverse-event difference disappeared. A LAMS result quoted without its removal protocol is not the intervention that was finally tested. Where publications name the stent it is named on the card (clarification exception); several reports describe the device class without a brand the abstract records, and those cards say so.

MeSH: ['Humans', 'Drainage', 'Stents', 'Endosonography', 'Pancreatitis, Acute Necrotizing', 'Treatment Outcome', 'Plastics', 'Self Expandable Metallic Stents', 'Metals', 'Necrosis']

Cards (5)

Card 1 — Bang 2019: LAMS were NOT superior to plastic stents (procedures median 2 vs 3, p = 0.192) and stent-related adverse events were higher with LAMS (32.3% vs 6.9%, p = 0.01) — until the protocol changed, n = 60

Study: Randomised equivalence trial (Bang et al.), Gut 2019

Population: 60 patients with walled-off necrosis randomised to EUS-guided drainage with LAMS (31) or plastic stents (29). Primary outcome: total number of procedures to achieve treatment success (symptom relief with walled-off necrosis resolution on CT at 6 months). The publication describes the stent by class (lumen-apposing metal stent); no brand name is given in the fetched record, so none is printed here.

Summary: Bang 2019: LAMS were NOT superior to plastic stents (procedures median 2 vs 3, p = 0.192) and stent-related adverse events were higher with LAMS (32.3% vs 6.9%, p = 0.01) — until the protocol changed, n = 60

Result: No significant difference in total procedures (median 2 [range 2–7] LAMS vs 3 [2–7] plastic; p = 0.192), treatment success, clinical adverse events, readmissions, length of stay or overall treatment costs. Procedure duration was shorter with LAMS (15 vs 40 minutes; p < 0.001), but stent-related adverse events (32.3% vs 6.9%; p = 0.01) and procedure costs (US $12,155 vs US $6,609; p < 0.001) were higher. PROTOCOL EVOLUTION: significant stent-related adverse events in the LAMS group occurred at ≥3 weeks after placement (the early safety signal in this literature, including bleeding); an interim audit amended the protocol so patients had a CT scan at 3 weeks and the LAMS was removed if the necrosis had resolved — after the amendment there was no significant difference in adverse events between the groups.

Watch out: The headline safety comparison mixes two protocol eras: LAMS left in place beyond 3 weeks vs LAMS removed at 3 weeks after imaging. Present the protocol evolution, not just the pooled adverse-event rate.

Source: Bang JY, Navaneethan U, Hasan MK, et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut. 2019. PMID: 29858393. Registry ID: NCT02685865. MeSH: Adult · Aged · Aged, 80 and over · Drainage · Endosonography · Equipment Design · Female · Humans · Length of Stay · Male · Middle Aged · Operative Time · Pancreatitis, Acute Necrotizing · Plastics · Postoperative Complications · Self Expandable Metallic Stents · Tomography, X-Ray Computed · Treatment Outcome · Young Adult

Card 2 — PROMETHEUS 2024: clinical success was similar with LAMS and plastic pigtail stents (short-term RR 1.41, 95% CI 0.88 to 2.25 — not significant); only procedure time clearly favoured LAMS, n = 64

Study: Open-label multicentre randomised trial (PROMETHEUS), Surg Endosc 2024

Population: 64 patients with symptomatic walled-off necrosis enrolled at 9 tertiary hospitals (screened 99), randomised to double-pigtail plastic stents (31) or LAMS (33) in an open-label multicentre trial. Primary outcome: short-term (4-week) clinical success by reduction of the collection. Devices are described by class in the record; no brand name is given in the fetched abstract, so none is printed here.

Summary: PROMETHEUS 2024: clinical success was similar with LAMS and plastic pigtail stents (short-term RR 1.41, 95% CI 0.88 to 2.25 — not significant); only procedure time clearly favoured LAMS, n = 64

Result: Short-term clinical success was similar (relative risk 1.41; 95% CI 0.88 to 2.25; p = 0.218), as was long-term success (RR 1.2; 95% CI 0.92 to 1.58; p = 0.291). Procedure duration was significantly shorter with LAMS (35 vs 45 minutes; p = 0.003). Hospital stay was similar. Reported stent-related adverse events were similar (36% LAMS vs 45% plastic), except de novo fever, which was lower with LAMS (RR 0.26; 95% CI 0.08 to 0.83; p = 0.015). The authors conclude the clinical superiority of LAMS over plastic stents was not proved.

Watch out: Open-label design; relative risks are relative measures and both success intervals cross 1 — this is a null result on success, not a trend to quote as benefit.

Source: PROMETHEUS — Gornals JB, Velasquez-Rodriguez JG, Bas-Cutrina F, et al. Plastic pigtail vs lumen-apposing metal stents for drainage of walled-off necrosis (PROMETHEUS study): an open-label, multicenter randomized trial. Surgical Endoscopy. 2024. PMID: 38448625. Registry ID: NCT03100578. MeSH: Humans · Treatment Outcome · Stents · Drainage · Length of Stay · Necrosis · Endosonography

Card 3 — Moon 2024 (infected walled-off necrosis): a novel electrocautery-enhanced LAMS did not reduce necrosectomy procedures (median 9 vs 4, p = 0.07) but clinical success at 8 weeks was 100% vs 73.9% (p = 0.03), n = 46

Study: Multicentre randomised study (electrocautery-enhanced LAMS, infected WON), Endoscopy 2024

Population: 46 patients with infected walled-off necrosis requiring EUS-guided drainage, randomised to a novel electrocautery-enhanced LAMS (23) or plastic stents (23) in a multicentre randomised study. Primary outcome: total number of direct endoscopic necrosectomy (DEN) procedures needed for clinical success. The record names the device by its class and design (novel electrocautery-enhanced LAMS); no brand name is given in the fetched abstract, so none is printed here.

Summary: Moon 2024 (infected walled-off necrosis): a novel electrocautery-enhanced LAMS did not reduce necrosectomy procedures (median 9 vs 4, p = 0.07) but clinical success at 8 weeks was 100% vs 73.9% (p = 0.03), n = 46

Result: The primary outcome did not differ significantly: median DEN procedures 9 (IQR 8.0–9.0) with LAMS vs 4 (IQR 2.5–5.0) with plastic stents (p = 0.07) — numerically more procedures with LAMS. Clinical success by intention-to-treat was higher with LAMS at 8 weeks (100% vs 73.9%; p = 0.03) but not at 4 weeks. Significant bleeding occurred in one patient in the plastic group and none in the LAMS group; no bleeding or buried-stent events occurred with LAMS within the study duration.

Watch out: Small (n = 46), infected-necrosis population only, and the significant result is a secondary time-point (8 weeks) while the primary outcome (necrosectomy count) was null and numerically favoured plastic — do not headline this trial as a LAMS win.

Source: Moon JH, Park SW, Lee YN, et al. A comparison of novel electrocautery-enhanced lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of infected walled-off necrosis: a multicenter randomized study. Endoscopy. 2024. PMID: 38857618. MeSH: Humans · Male · Female · Middle Aged · Drainage · Stents · Endosonography · Pancreatitis, Acute Necrotizing · Electrocoagulation · Plastics · Adult · Aged · Treatment Outcome · Metals · Ultrasonography, Interventional

Card 4 — Meta-analysis 2025 (7 RCTs): no difference between metal and plastic stents in treatment success, bleeding or mortality — only procedure duration favoured metal (mean difference −11.32 minutes)

Study: Meta-analysis of randomised trials, J Minim Access Surg 2025

Population: Pooled randomised trials comparing metal vs plastic stents for drainage of walled-off pancreatic necrosis, searched to December 2024; seven RCTs met inclusion. This is a synthesis of the same trial population carded above, not independent patients.

Summary: Meta-analysis 2025 (7 RCTs): no difference between metal and plastic stents in treatment success, bleeding or mortality — only procedure duration favoured metal (mean difference −11.32 minutes)

Result: Procedure duration was significantly shorter with metal stents (mean difference −11.32 minutes; 95% CI −17.75 to −4.88). There was no difference between groups in stent-related periprocedural adverse events, bleeding, serious bleeding, treatment success, need for or number of necrosectomies, reinterventions, percutaneous drainage, surgery, duration of hospitalisation, mortality, stent dysfunction or recurrence.

Watch out: A meta-analysis of the same small RCTs carded in this pack — it pools, and cannot add to, their patient base; the constituent trials used different LAMS dwell-time protocols, which the pooled adverse-event rates conceal.

Source: Giri S, Gore P, Khatana G, et al. Comparative outcome of metal versus plastic stents for the management of walled-off pancreatic necrosis — an updated meta-analysis of randomised studies. Journal of Minimal Access Surgery. 2025. PMID: 40693902. MeSH: not captured from the record

Card 5 — Synthesis: no consistent LAMS advantage on success; the durable lessons are shorter procedures and the 3-week imaging-and-removal protocol (PMIDs 29858393, 38448625, 38857618, 40693902)

Study: Synthesis

Population: Adults with (often infected) pancreatic walled-off necrosis undergoing EUS-guided drainage; randomised base 170 patients across three trials (60 + 64 + 46), plus a meta-analysis of seven RCTs.

Summary: Synthesis: no consistent LAMS advantage on success; the durable lessons are shorter procedures and the 3-week imaging-and-removal protocol (PMIDs 29858393, 38448625, 38857618, 40693902)

Result: Treatment success does not consistently differ between LAMS and plastic stents; LAMS procedures are consistently shorter; and the early LAMS safety signal (bleeding-type stent events at ≥3 weeks) was a dwell-time problem that the field answered with interval imaging and early removal. Synthesis rests on PMIDs 29858393, 38448625, 38857618 and 40693902.

Watch out: SPLIT stamp: anyone quoting a single favourable trial (or the pooled success rate) without the dwell-time protocol is misrepresenting this literature.

Source: Synthesis of this pack's own cards: Bang 2019 PMID 29858393; PROMETHEUS PMID 38448625; Moon 2024 PMID 38857618; meta-analysis PMID 40693902. Registry IDs: NCT02685865; NCT03100578.