SourceMed · Shelf #6784 in the ask interface

Inverted ILM flap for large macular holes: closure 98% versus 88% in the originating randomised trial, with flat-open holes almost abolished (2% vs 19%) and better 12-month vision; a four-trial meta-analysis gives odds ratio 4.89 for anatomic success

Shelf #6784 · Eyes, skin, nose & allergy

LIKELY (benefit) — for large macular holes (>400 µm) the inverted ILM flap closes more holes than conventional peeling (98% vs 88% in the originating trial; pooled odds ratio 4.89 across four randomised trials) and nearly abolishes the flat-open outcome, with a smaller visual-acuity advantage

Stamped: 2026-11-28.

Evidence published: 2010–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with large full-thickness macular holes (>400 µm), does vitrectomy with an inverted internal-limiting-membrane flap improve hole closure and vision versus conventional ILM peeling?

Balance of the evidence

LIKELY (benefit) for closure of large holes. This pack is the PARTIAL slice the library lacked: pack #4614 asks about ocriplasmin injection and pack #6621 asks about face-down posturing after macular-hole vitrectomy — neither asks the flap-versus-peel technique question, and no homed report is carded here. The originating randomised trial (Michalewska 2010; 101 eyes with holes >400 µm) found closure in 98% with the inverted flap versus 88% with standard peeling, flat-open holes (closed but with bare pigment epithelium and poor vision) in 2% versus 19%, and better mean 12-month acuity (0.28 versus 0.17; P=0.001). A second randomised trial in still larger holes (Kannan 2018; 60 patients, holes 600-1500 µm) found anatomical success 90.0% versus 70.0% — the same direction, not statistically significant on its own (P=0.125). The meta-analysis of the four randomised trials (Chen 2020; 276 eyes) pooled an odds ratio of 4.89 (95% CI 2.09-11.47) for anatomic success and 5.23 (95% CI 2.83-9.66) for type 1 closure in favour of the flap, with better postoperative acuity. LIKELY (benefit) for anatomical closure; the visual advantage is smaller and less certain than the closure advantage.

MeSH: ['Humans', 'Basement Membrane/surgery', 'Retinal Perforations/surgery', 'Surgical Flaps', 'Vitrectomy', 'Visual Acuity', 'Treatment Outcome', 'Tomography, Optical Coherence']

Cards (4)

Card 1 — Michalewska 2010 (prospective randomised trial, 101 eyes, holes >400 µm): inverted flap versus standard vitrectomy with ILM peeling — closure 98% versus 88%, flat-open 2% versus 19%, 12-month acuity 0.28 versus 0.17 (P=0.001)

Study: Prospective randomised clinical trial (Michalewska 2010)

Population: Patients with macular holes larger than 400 µm: group 1, 51 eyes of 40 patients, underwent standard three-port pars plana vitrectomy with complete ILM removal and air; group 2, 50 eyes of 46 patients, underwent the inverted ILM flap technique, in which a stained ILM remnant left attached to the hole margins is inverted to cover the hole; spectral optical coherence tomography and examination were performed to 12 months.

Summary: Michalewska 2010 (prospective randomised trial, 101 eyes, holes >400 µm): inverted flap versus standard vitrectomy with ILM peeling — closure 98% versus 88%, flat-open 2% versus 19%, 12-month acuity 0.28 versus 0.17 (P=0.001)

Result: Macular hole closure was observed in 88% of group 1 and 98% of group 2. A flat-open appearance (flat hole roof with bare retinal pigment epithelium) occurred in 19% of group 1 versus 2% of group 2. Mean (or median) postoperative visual acuity at 12 months was 0.17 (range 0.1-0.6) in group 1 versus 0.28 (range 0.02-0.8) in group 2 (P=0.001), from preoperative means of 0.12 and 0.078 respectively. The authors conclude the flap technique prevents the flat-open appearance and improves anatomic and functional outcomes for holes over 400 µm.

Watch out: The originating centre's trial, with the technique's inventors as operators — the closure gap (98% vs 88%) is modest in absolute terms and the headline benefit is as much about the quality of closure (flat-open abolition) as about closure itself. Acuity is reported as decimal means/medians with wide, overlapping ranges.

Source: Michalewska Z et al. Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology. 2010. PMID: 20541263. Registry ID: none in the record (pre-registration-era trial). MeSH: Aged · Basement Membrane/surgery · Female · Fluorescein Angiography · Humans · Male · Ophthalmologic Surgical Procedures · Prospective Studies · Retinal Perforations/diagnosis/physiopathology/surgery · Retinal Pigment Epithelium/pathology · Surgical Flaps · Tomography, Optical Coherence · Visual Acuity/physiology · Vitrectomy

Card 2 — Kannan 2018 (randomised trial, 60 patients, holes 600-1500 µm): inverted flap versus peeling — anatomical success 90.0% versus 70.0% (P=0.125, not significant), acuity modestly better with the flap (also not significant)

Study: Randomised controlled trial (Kannan 2018)

Population: 60 patients with idiopathic large full-thickness macular holes (minimum diameter 600-1500 µm; mean minimum diameter about 760 µm in the peeling group and 803 µm in the flap group), randomised to ILM peeling (group A, 30 patients) or inverted ILM flap (group B, 30 patients), with anatomical and visual outcomes at 6 months; anatomical success required flattening of the hole with neurosensory retina completely covering the fovea.

Summary: Kannan 2018 (randomised trial, 60 patients, holes 600-1500 µm): inverted flap versus peeling — anatomical success 90.0% versus 70.0% (P=0.125, not significant), acuity modestly better with the flap (also not significant)

Result: Anatomical success was 70.0% in group A versus 90.0% in group B (P=0.125). Mean best-corrected acuity at 6 months was logMAR 0.65 (Snellen equivalent 20/89) versus logMAR 0.53 (20/68) (P=0.060); mean improvement was 1.4 versus 2.1 lines (P=0.353), and acuity of 20/60 or better was achieved by 13.3% versus 20.0% (P=0.766). The authors conclude the outcomes are statistically similar between the techniques in this sample.

Watch out: The honest counterweight card: in the largest holes, an independent centre found a 20-point closure advantage that its 60-patient sample could not confirm statistically. Direction agrees with Michalewska; precision does not. Registered with the Clinical Trials Registry - India as CTRI/2017/11/010474, as reported in the record.

Source: Kannan NB et al. Comparative study of inverted internal limiting membrane (ILM) flap and ILM peeling technique in large macular holes: a randomized-control trial. BMC ophthalmology. 2018. PMID: 30029621. Registry ID: CTRI/2017/11/010474 (Clinical Trials Registry - India, as reported in the record). MeSH: Adult · Aged · Basement Membrane/surgery · Female · Follow-Up Studies · Fovea Centralis/pathology · Humans · Male · Middle Aged · Prospective Studies · Retinal Perforations/diagnosis/physiopathology/surgery · Surgical Flaps · Tomography, Optical Coherence · Treatment Outcome · Visual Acuity · Vitrectomy/methods

Card 3 — Chen 2020 (meta-analysis of 4 randomised trials, 276 eyes): anatomic success odds ratio 4.89 and type 1 closure odds ratio 5.23 in favour of the inverted flap, with better postoperative acuity

Study: Meta-analysis of randomised controlled trials (Chen 2020)

Population: Four randomised trials (276 eyes: 135 inverted flap, 141 conventional peeling) in idiopathic large macular holes, all using gas tamponade, with follow-up of 3 months in two studies, 6 months in one and 12 months in one; outcomes were anatomic success, type 1 closure (neurosensory retina present over the hole), postoperative best-corrected acuity and change in acuity.

Summary: Chen 2020 (meta-analysis of 4 randomised trials, 276 eyes): anatomic success odds ratio 4.89 and type 1 closure odds ratio 5.23 in favour of the inverted flap, with better postoperative acuity

Result: Anatomic success favoured the inverted flap (odds ratio 4.89; 95% CI 2.09-11.47; P=0.0003), as did type 1 closure (odds ratio 5.23; 95% CI 2.83-9.66; P<0.00001). Postoperative logMAR acuity and mean change in acuity also favoured the flap (weighted mean differences 0.17, 95% CI 0.11-0.24, and 0.08, 95% CI 0.01-0.16, respectively). Odds ratios are relative measures: with closure already near 88-90% on peeling, an odds ratio near 5 corresponds to a much smaller absolute gain, of the order of the 98% versus 88% seen in the originating trial.

Watch out: Four small trials, two of them carded above — the pooled estimate inherits their single-centre and inventor-centre features, and follow-up is as short as 3 months in half the base. The acuity advantage (0.08-0.17 logMAR) is about one line or less.

Source: Chen G et al. Inverted ILM flap technique versus conventional ILM peeling for idiopathic large macular holes: A meta-analysis of randomized controlled trials. PloS one. 2020. PMID: 32706833. Registry ID: none in the record. MeSH: Aged · Basement Membrane/pathology/surgery · Databases as Topic · Humans · Middle Aged · Randomized Controlled Trials as Topic · Retina/pathology/surgery · Retinal Perforations/surgery · Surgical Flaps · Treatment Outcome · Visual Acuity

Card 4 — Synthesis: LIKELY (benefit) for closure — the flap's clearest win is converting flat-open failures into true closures

Study: Synthesis

Population: Two individually carded randomised trials (101 and 60 eyes) within a four-trial, 276-eye meta-analysis, all in holes over 400 µm. Cross-points: pack #4614 (ocriplasmin injection) and pack #6621 (face-down posturing) cover neighbouring macular-hole questions; none of their reports is carded here.

Summary: Synthesis: LIKELY (benefit) for closure — the flap's clearest win is converting flat-open failures into true closures

Result: Closure 98% vs 88% and flat-open 2% vs 19% (Michalewska); 90.0% vs 70.0% closure, not significant alone (Kannan); pooled odds ratio 4.89 for anatomic success and 5.23 for type 1 closure, with a small acuity advantage. LIKELY (benefit) for anatomical closure in large holes.

Watch out: Evidence is confined to idiopathic large holes in surgical series; it does not address small holes (where peeling already closes nearly all), traumatic or secondary holes, or surgeon learning curves with the flap technique.

Source: Synthesis of Michalewska Z et al. Ophthalmology. 2010 (PMID: 20541263); Kannan NB et al. BMC ophthalmology. 2018 (PMID: 30029621); Chen G et al. PloS one. 2020 (PMID: 32706833).