The cuff-leak test predicts post-extubation stridor with high specificity but only moderate sensitivity: pooled specificity 0.87–0.88 and sensitivity 0.62–0.66 across 28 studies (4,493 extubations) — a low leak flags risk, but a normal leak does not clear a patient, and early single-centre cut-offs (110–130 mL) performed better than the pooled test
Shelf #6844 · Critical care & sepsis
POSSIBLE — as a diagnostic-accuracy shelf: the cuff-leak test is a specific but only moderately sensitive screen; a positive (low-leak) result usefully flags risk, a negative result does not exclude stridor, and a low leak alone should not postpone extubation indefinitely
Stamped: 2026-11-28.
Evidence published: 1996–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In mechanically ventilated adults being considered for extubation, does the cuff-leak test (cuff-leak volume/percentage) predict post-extubation stridor and reintubation accurately enough to guide extubation decisions?
Balance of the evidence
POSSIBLE, framed as diagnostic accuracy, not as a treatment effect. The three classic prospective cohorts agree that patients who develop post-extubation stridor have much smaller cuff leaks: Miller & Cole 1996 (100 intubations; stridor in 6%; mean leak 180 vs 360 mL; a leak <110 mL had positive predictive value 0.80 and specificity 0.99), Jaber 2003 (112 extubations; stridor incidence 12%; at thresholds of 130 mL and 12% of tidal volume, sensitivity 85% and specificity 95%), and Sandhu 2000 (110 trauma patients; stridor/reintubation groups had leaks of about 8–9% of tidal volume; a leak <10% had 96% specificity). The 2020 meta-analysis (28 studies, 4,493 extubations) tempers the early numbers: pooled sensitivity 0.62 and specificity 0.87 for post-extubation airway obstruction, and sensitivity 0.66 / specificity 0.88 for reintubation, with substantial heterogeneity. The clinical reading the source literature supports: use a low leak to trigger preparation (steroids, anaesthesia presence, delayed extubation in selected patients) — but do not treat a reassuring leak as clearance, and do not let a single low leak postpone extubation indefinitely, since most low-leak patients still extubate without stridor. Extubation-strategy shelves (packs #1309/#3133–#3135) and the SBT shelf (live #1321) ask different questions and are not duplicated.
MeSH: ['Aged', 'Female', 'Humans', 'Intubation, Intratracheal', 'Laryngeal Edema/complications', 'Male', 'Middle Aged', 'Predictive Value of Tests', 'Respiration, Artificial', 'Respiratory Insufficiency/therapy', 'Respiratory Sounds/etiology']
Cards (5)
Card 1 — Miller & Cole 1996: pre-extubation cuff leak was 180 vs 360 mL in patients who did vs did not develop stridor; a leak <110 mL had PPV 0.80 and specificity 0.99 (100 intubations)
Study: Prospective diagnostic cohort study
Population: 100 consecutive intubations in a general medical ICU population; cuff-leak volume (inspiratory minus averaged expiratory tidal volume with the cuff deflated) was recorded within 24 h of starting and of ending mechanical ventilation. Post-extubation stridor accompanied 6% of extubations.
Summary: Miller & Cole 1996: pre-extubation cuff leak was 180 vs 360 mL in patients who did vs did not develop stridor; a leak <110 mL had PPV 0.80 and specificity 0.99 (100 intubations)
Result: Mean pre-extubation cuff-leak volume was significantly lower in patients who developed stridor than in those who did not (180 ± 157 mL vs 360 ± 157 mL; p=0.012). For a cuff leak <110 mL, the positive predictive value for post-extubation stridor was 0.80, the predictive value for absence of stridor with a leak >110 mL was 0.98, and specificity was 0.99. No other demographic or ventilation variables differed significantly between the groups.
Watch out: Only about six stridor events underpin the cut-off: a PPV of 0.80 built on a handful of cases is fragile, and stridor prevalence (6%) was low — predictive values will fall further where stridor is rarer and rise where it is commoner. Single-centre, 1996 ventilator practice.
Source: Miller RL, Cole RP. Association between reduced cuff leak volume and postextubation stridor. Chest. 1996. PMID: 8874265. Registry ID: none in the record. MeSH: Aged · Female · Humans · Intubation, Intratracheal · Laryngeal Edema/complications · Male · Middle Aged · Predictive Value of Tests · Respiration, Artificial · Respiratory Insufficiency/therapy · Respiratory Sounds/etiology
Card 2 — Jaber 2003: stridor incidence 12%; at cut-offs of 130 mL and 12%, cuff-leak sensitivity was 85% and specificity 95% (112 extubations)
Study: Prospective diagnostic cohort study
Population: 112 extubations in 112 patients in a university-hospital ICU over 14 months, each preceded by a cuff-leak test; the study also evaluated risk factors for post-extubation stridor.
Summary: Jaber 2003: stridor incidence 12%; at cut-offs of 130 mL and 12%, cuff-leak sensitivity was 85% and specificity 95% (112 extubations)
Result: Stridor incidence was 12%. Patients who developed stridor had a much lower cuff leak than the others, in absolute values (59 ± 92 mL vs 372 ± 170 mL; p<0.001) and relative values (9 ± 13% vs 56 ± 20%; p<0.001). At thresholds of 130 mL and 12% of tidal volume, sensitivity was 85% and specificity 95%. Stridor was also associated with higher SAPS II score, medical admission, traumatic or difficult intubation, self-extubation history, an over-inflated cuff at ICU admission and prolonged intubation.
Watch out: The best-performing cut-offs in the literature come from this single centre; the same paper shows stridor is multifactorial (intubation trauma, duration, cuff over-inflation), so the leak is one risk marker among several, not a standalone gate.
Source: Jaber S et al. Post-extubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test. Intensive care medicine. 2003. PMID: 12528025. Registry ID: none in the record. MeSH: Airway Obstruction/epidemiology,etiology,prevention & control · Female · France/epidemiology · Humans · Intensive Care Units · Intubation, Intratracheal/adverse effects,instrumentation · Laryngeal Edema/etiology,prevention & control · Male · Manometry/methods · Middle Aged · Prospective Studies · ROC Curve · Respiratory Sounds/etiology · Risk Factors · Sensitivity and Specificity · Statistics, Nonparametric
Card 3 — Sandhu 2000: patients with stridor or stridor requiring reintubation had cuff leaks of only ~8–9% of tidal volume; a leak <10% had 96% specificity (110 trauma patients)
Study: Prospective diagnostic cohort study (trauma population)
Population: 110 consecutive trauma patients at a level I trauma centre who met standard weaning-protocol criteria and were studied prospectively at extubation; the commonest reason for intubation was closed-head injury. Percent cuff leak was the exhaled tidal-volume change on cuff deflation divided by the pre-deflation exhaled tidal volume; patients were followed for 24 h after extubation.
Summary: Sandhu 2000: patients with stridor or stridor requiring reintubation had cuff leaks of only ~8–9% of tidal volume; a leak <10% had 96% specificity (110 trauma patients)
Result: Seven patients (6.4%) developed stridor alone, with a mean cuff leak of 58 mL (8.4% of tidal volume); six patients (5.5%) developed stridor requiring reintubation, with a mean leak of 68 mL (9.2%). Patients who developed stridor or needed reintubation had been intubated significantly longer. A cuff leak of less than 10% of tidal volume identified patients at risk for stridor or reintubation with 96% specificity. The authors note the leak decreases after more than 3 days of intubation.
Watch out: A young trauma population with head injury predominating is not a general medical ICU population; event counts are small (7 and 6 patients), and the record's own numbers show intubation duration confounds the leak–stridor relationship.
Source: Sandhu RS et al. Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation. Journal of the American College of Surgeons. 2000. PMID: 10873003. Registry ID: none in the record. MeSH: Craniocerebral Trauma/therapy · Edema/etiology · Female · Humans · Intubation, Intratracheal/instrumentation · Laryngeal Diseases/etiology · Male · Prospective Studies · Respiratory Sounds/etiology · Tidal Volume · Time Factors · Tracheal Diseases/etiology · Treatment Failure · Wounds and Injuries/therapy
Card 4 — Meta-analysis 2020: across 28 studies and 4,493 extubations, pooled sensitivity was only 0.62 for airway obstruction (specificity 0.87) and 0.66 for reintubation (specificity 0.88)
Study: Systematic review and meta-analysis of diagnostic-accuracy studies
Population: Systematic review and meta-analysis of diagnostic-accuracy studies of the cuff-leak test in intubated adults in critical care, searching to March 2020: 28 studies involving 4,493 extubations; only three studies were at low risk of bias across all QUADAS-2 domains. Sensitivities and specificities were pooled with a bivariate random-effects model.
Summary: Meta-analysis 2020: across 28 studies and 4,493 extubations, pooled sensitivity was only 0.62 for airway obstruction (specificity 0.87) and 0.66 for reintubation (specificity 0.88)
Result: For post-extubation airway obstruction, pooled sensitivity was 0.62 (95% CI 0.49–0.73; I²=81.6%) and pooled specificity 0.87 (95% CI 0.82–0.90; I²=97.8%). For reintubation, pooled sensitivity was 0.66 (95% CI 0.46–0.81) and specificity 0.88 (95% CI 0.83–0.92). Subgroup analyses suggested the type of cuff-leak test influenced sensitivity heterogeneity and intubation length influenced specificity heterogeneity. The authors conclude the test has excellent specificity but moderate sensitivity: clinicians should consider intervening when the test is positive, but patients still need close monitoring after extubation when it is negative.
Watch out: Heterogeneity is very high (I² up to 97.8%) and test methods (qualitative vs quantitative, absolute vs percent thresholds) varied across studies — the pooled pair is an average over different tests, which is why the early single-centre cut-offs should not be quoted as the test's settled performance.
Source: Kuriyama A et al. Performance of the cuff leak test in adults in predicting post-extubation airway complications: a systematic review and meta-analysis. Critical care (London, England). 2020. PMID: 33160405. Registry ID: none in the record. MeSH: Adult · Airway Extubation/instrumentation,methods · Humans · Predictive Value of Tests · Pressure · Sensitivity and Specificity · Weights and Measures/instrumentation,standards
Card 5 — Synthesis: a rule-in aid, not a rule-out — POSSIBLE as an accuracy shelf; prepare for stridor when the leak is low, monitor regardless when it is not
Study: Synthesis
Population: Synthesis of the cards above: three prospective cohorts (100, 112 and 110 patients/extubations) and a 28-study meta-analysis (4,493 extubations).
Summary: Synthesis: a rule-in aid, not a rule-out — POSSIBLE as an accuracy shelf; prepare for stridor when the leak is low, monitor regardless when it is not
Result: The direction is unanimous — smaller leak, more stridor — and the pooled specificity (0.87–0.88) makes a low leak a useful rule-in signal. The pooled sensitivity (0.62–0.66) is the discipline on enthusiasm: roughly a third of patients who will develop obstruction or need reintubation pass the test, so a normal leak changes monitoring intensity, not vigilance. The classic cut-offs (110 mL, 130 mL, 10–12% of tidal volume) come from small single-centre cohorts and performed better there than the test performs on average. Nothing carded here shows that acting on the test (steroids, delayed extubation) improves outcomes — that is a treatment question this accuracy shelf does not answer, and a low leak by itself should not postpone extubation indefinitely.
Watch out: Predictive values (unlike sensitivity/specificity) move with local stridor prevalence: Miller & Cole's PPV of 0.80 was earned at 6% prevalence in one ICU and will not travel unchanged.
Source: Synthesis of Miller RL, Cole RP. Chest. 1996 (PMID: 8874265), Jaber S et al. Intensive Care Med. 2003 (PMID: 12528025), Sandhu RS et al. J Am Coll Surg. 2000 (PMID: 10873003) and Kuriyama A et al. Crit Care. 2020 (PMID: 33160405).