SourceMed · Shelf #6847 in the ask interface

PHYSIOLOGY — Dynamic heart–lung indices of fluid responsiveness: pulse pressure variation above ~13% identifies fluid responders (sensitivity 94%, specificity 96% in the founding study), stroke volume variation behaves similarly, and a 15-second end-expiratory occlusion that raises cardiac index ≥5% predicts responsiveness — all of it valid only under controlled ventilation, adequate tidal volume, sinus rhythm and no spontaneous effort

Shelf #6847 · Critical care & sepsis

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 2000–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In mechanically ventilated adults, how do respiratory variations in pulse pressure and stroke volume, and the end-expiratory occlusion test, predict fluid responsiveness — what are the thresholds, and under what conditions (tidal volume, rhythm, spontaneous effort, lung compliance) do they fail?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. The textbook framing (Guyton & Hall's account of heart–lung interaction: positive-pressure inspiration cyclically raises intrathoracic pressure, impedes venous return and left-ventricular preload, and so makes arterial pulse pressure swing with the breath — the swing is large only when the ventricles sit on the steep part of the Frank–Starling curve, which is precisely the fluid-responsive state) is borne out by concordant primary human data. Michard 2000 (40 septic, ventilated patients): a pre-infusion pulse pressure variation of 13% separated responders from non-responders with sensitivity 94% and specificity 96%, and the variation correlated tightly with the cardiac-index response (r²=0.85). Berkenstadt 2001 (15 neurosurgical patients, 140 graded volume loads): stroke volume variation ≥9.5% predicted a stroke-volume rise with sensitivity 79% and specificity 93%, far outperforming central venous pressure (AUC 0.870 vs 0.493). Monnet 2009 (34 ventilated patients with shock): a 15-second end-expiratory occlusion — which removes the cyclic inspiratory impediment and acts as a reversible internal fluid challenge — predicted responsiveness when cardiac index rose ≥5% (sensitivity 91%, specificity 100%). The meta-analytic average (Yang 2014: 22 studies, 807 patients, pooled AUC 0.94) was earned only in patients ventilated with tidal volume >8 mL/kg, without spontaneous breathing and without arrhythmia — those validity conditions are part of the physiology, printed on the cards, not fine print: with low tidal volumes, spontaneous efforts, irregular rhythm or poor lung compliance the indices lose discrimination. Passive leg raising is a separate, already-homed test (pack #3151), cross-pointed and not duplicated.

MeSH: ['Adolescent', 'Adult', 'Aged', 'Aged, 80 and over', 'Blood Pressure', 'Body Fluids', 'Female', 'Humans', 'Male', 'Middle Aged', 'Pulse', 'Respiration', 'Respiration, Artificial', 'Shock, Septic/physiopathology,therapy']

Cards (5)

Card 1 — Michard 2000: pre-infusion pulse pressure variation was 24% in fluid responders vs 7% in non-responders; a 13% threshold gave sensitivity 94% and specificity 96% (40 septic ventilated patients)

Study: Primary human physiology study (prospective, ventilated septic patients)

Population: 40 mechanically ventilated patients with acute circulatory failure related to sepsis, instrumented with systemic and pulmonary artery catheters, studied before and after volume expansion. Responders (16) were patients whose cardiac index rose ≥15% with volume expansion; 24 were non-responders. Respiratory pulse pressure variation (ΔPp) was calculated over one respiratory cycle as (Ppmax − Ppmin) divided by their mean.

Summary: Michard 2000: pre-infusion pulse pressure variation was 24% in fluid responders vs 7% in non-responders; a 13% threshold gave sensitivity 94% and specificity 96% (40 septic ventilated patients)

Result: Before volume expansion, ΔPp was 24 ± 9% in responders vs 7 ± 3% in non-responders (p<0.001), and respiratory systolic pressure variation was 15 ± 5% vs 6 ± 3%. ROC analysis showed ΔPp was a more accurate indicator of fluid responsiveness than systolic pressure variation; a ΔPp of 13% discriminated responders from non-responders with sensitivity 94% and specificity 96%. Pre-infusion ΔPp correlated closely with the volume-induced cardiac-index increase (r²=0.85, p<0.001), and volume expansion itself reduced ΔPp from 14 ± 10% to 7 ± 5%.

Watch out: Forty patients with sepsis on controlled ventilation in one centre, against a pulmonary-artery-catheter reference standard. The 13% threshold's performance degrades outside its validity conditions (spontaneous breathing, arrhythmia, low tidal volume) — see the meta-analysis card.

Source: Michard F et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. American journal of respiratory and critical care medicine. 2000. PMID: 10903232. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Blood Pressure · Body Fluids · Female · Humans · Male · Middle Aged · Pulse · Respiration · Respiration, Artificial · Shock, Septic/physiopathology,therapy

Card 2 — Berkenstadt 2001: stroke volume variation ≥9.5% predicted a stroke-volume response (sensitivity 79%, specificity 93%; AUC 0.870), while central venous pressure performed at chance (AUC 0.493) — 15 patients, 140 graded volume loads

Study: Primary human physiology study (prospective, intraoperative)

Population: 15 patients undergoing brain surgery, monitored with a PiCCO continuous cardiac output monitor displaying stroke volume variation (SVV: the percentage change between maximal and minimal stroke volumes over a floating 30-second period). Graded volume loading was performed in 100 mL steps of 6% hydroxyethyl starch, repeated while each step raised stroke volume >5% (responsive) until a step changed it <5% (non-responsive): 140 volume-loading steps in total.

Summary: Berkenstadt 2001: stroke volume variation ≥9.5% predicted a stroke-volume response (sensitivity 79%, specificity 93%; AUC 0.870), while central venous pressure performed at chance (AUC 0.493) — 15 patients, 140 graded volume loads

Result: Responsive and non-responsive loading steps differed in pre-load systolic blood pressure, stroke volume and SVV, but not in heart rate or central venous pressure. By ROC analysis, the area under the curve for SVV was 0.870 (95% CI 0.809–0.903), statistically greater than for central venous pressure (0.493, 0.397–0.590), heart rate (0.593) and systolic blood pressure (0.729). An SVV of 9.5% or more predicted an increase in stroke volume of at least 5% after a 100 mL load with sensitivity 79% and specificity 93%.

Watch out: Only 15 patients (the 140 observations are repeated loads within them, not 140 patients), in neurosurgical patients receiving a colloid, with a lenient response definition (stroke volume +5% after only 100 mL). The durable lesson is the contrast with static pressures, not the exact 9.5% cut-off.

Source: Berkenstadt H et al. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesthesia and analgesia. 2001. PMID: 11273937. Registry ID: none in the record. MeSH: Aged · Brain/surgery · Central Venous Pressure/physiology · Fluid Therapy · Hemodynamics/physiology · Humans · Hydroxyethyl Starch Derivatives/therapeutic use · Male · Middle Aged · Neurosurgical Procedures · Plasma Substitutes/therapeutic use · Predictive Value of Tests · Stroke Volume/physiology

Card 3 — Monnet 2009: a 15-second end-expiratory occlusion raised cardiac index ≥5% only in fluid responders — sensitivity 91%, specificity 100% (34 ventilated patients with shock)

Study: Primary human physiology study (prospective, ventilated ICU patients)

Population: 34 mechanically ventilated patients with shock in a medical ICU in whom volume expansion was planned. Each patient underwent a 15-second end-expiratory occlusion followed by a 500 mL saline infusion, with arterial pressure and pulse-contour cardiac index (PiCCOplus) measured at baseline, during passive leg raising, in the last 5 seconds of the occlusion, and after volume expansion. Twenty-three patients were responders (cardiac index rise >15% after volume expansion).

Summary: Monnet 2009: a 15-second end-expiratory occlusion raised cardiac index ≥5% only in fluid responders — sensitivity 91%, specificity 100% (34 ventilated patients with shock)

Result: Before volume expansion, the end-expiratory occlusion increased arterial pulse pressure by 15 ± 15% and cardiac index by 12 ± 11% in responders, with no significant change in non-responders. A pulse-pressure rise ≥5% during occlusion predicted fluid responsiveness with sensitivity 87% and specificity 100%; a cardiac-index rise ≥5% predicted it with sensitivity 91% and specificity 100% (ROC area 0.972). Accuracy was similar to the cardiac-index response to passive leg raising and significantly better than the pulse-pressure response to leg raising (ROC area 0.675).

Watch out: The occlusion test needs a ventilator that can hold an end-expiratory pause and a patient making no inspiratory effort during it — a spontaneous breath inside the 15 seconds invalidates the manoeuvre. Thirty-four patients, one centre, one monitoring platform (PiCCO pulse contour).

Source: Monnet X et al. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Critical care medicine. 2009. PMID: 19237902. Registry ID: none in the record. MeSH: Fluid Therapy · Hemodynamics · Humans · Intensive Care Units · Positive-Pressure Respiration · Prospective Studies · Respiration, Artificial · Time Factors

Card 4 — Yang 2014 meta-analysis: pooled PPV performance (sensitivity 0.88, specificity 0.89, AUC 0.94) was demonstrated only at tidal volume >8 mL/kg, without spontaneous breathing or arrhythmia (22 studies, 807 patients)

Study: Systematic review and meta-analysis of diagnostic-accuracy studies

Population: Systematic review and meta-analysis of clinical trials of pulse pressure variation (PPV) for predicting fluid responsiveness after fluid challenge in mechanically ventilated ICU patients: 22 studies with 807 patients, of whom 465 (58%) were responders. Included studies enrolled patients with tidal volume more than 8 mL/kg and without spontaneous breathing and cardiac arrhythmia.

Summary: Yang 2014 meta-analysis: pooled PPV performance (sensitivity 0.88, specificity 0.89, AUC 0.94) was demonstrated only at tidal volume >8 mL/kg, without spontaneous breathing or arrhythmia (22 studies, 807 patients)

Result: Pooled sensitivity was 0.88 (95% CI 0.81 to 0.92) and pooled specificity 0.89 (95% CI 0.84 to 0.92); the summary ROC area under the curve was 0.94 (95% CI 0.91 to 0.95). A significant threshold effect was identified across studies.

Watch out: The eligibility conditions are the finding: this pooled accuracy does not describe modern lung-protective ventilation at 6 mL/kg, patients triggering the ventilator, or patients in atrial fibrillation — in those settings the founding thresholds should not be applied as if validated.

Source: Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Critical care (London, England). 2014. PMID: 25427970. Registry ID: none in the record. MeSH: Blood Pressure/physiology · Clinical Trials as Topic/methods,trends · Critical Illness/therapy · Fluid Therapy/methods,trends · Hemodynamics/physiology · Humans · Intensive Care Units/trends · Tidal Volume/physiology

Card 5 — Synthesis: textbook heart–lung interaction, quantified — ESTABLISHED physiology whose thresholds carry their validity conditions with them

Study: Synthesis

Population: Synthesis of the cards above: Michard 2000 (40 patients), Berkenstadt 2001 (15 patients, 140 volume loads), Monnet 2009 (34 patients) and the Yang 2014 meta-analysis (22 studies, 807 patients). Textbook framing: Guyton & Hall (heart–lung interaction, venous return and the Frank–Starling mechanism) and Ganong.

Summary: Synthesis: textbook heart–lung interaction, quantified — ESTABLISHED physiology whose thresholds carry their validity conditions with them

Result: The mechanism the textbooks describe — cyclic inspiratory impedance of venous return translating into arterial pressure swings whose size reports position on the Frank–Starling curve — is directly quantified in humans: pulse pressure variation threshold ~13% (sensitivity 94%, specificity 96%), stroke volume variation threshold ~9.5% (AUC 0.870 vs 0.493 for central venous pressure), and the end-expiratory occlusion test (cardiac-index rise ≥5% during a 15-second hold; sensitivity 91%, specificity 100%), which works by transiently removing the inspiratory impediment rather than by giving fluid. The stamp is PHYSIOLOGY — ESTABLISHED because the primary studies and their synthesis are concordant; the conditions are part of the establishment — controlled ventilation, tidal volume ≥8 mL/kg for classic PPV, sinus rhythm, no spontaneous effort, and adequate lung compliance — and outside them the same numbers are not established at all. Passive leg raising, the non-ventilator-dependent alternative, is homed on pack #3151 and is cross-pointed, not duplicated.

Watch out: Fluid responsiveness is a physiological state, not an instruction to give fluid: these indices say the circulation can respond, and say nothing about whether it should — that judgement needs the clinical picture (perfusion, congestion, lung water) the indices do not measure.

Source: Synthesis of Michard F et al. Am J Respir Crit Care Med. 2000 (PMID: 10903232), Berkenstadt H et al. Anesth Analg. 2001 (PMID: 11273937), Monnet X et al. Crit Care Med. 2009 (PMID: 19237902) and Yang X, Du B. Crit Care. 2014 (PMID: 25427970). Textbook framing: Guyton & Hall Textbook of Medical Physiology; Ganong's Review of Medical Physiology. Cross-point: pack #3151 (passive leg raising).