SourceMed · Shelf #6927 in the ask interface

Wound-edge protectors: meta-analyses claim a third fewer infections, the large ROSSINI trial found none

Shelf #6927 · Emergency & first hours

SPLIT — meta-analyses of small trials favour protectors (relative risk ~0.6), but the large ROSSINI randomised trial found no difference (24.7% vs 25.4%)

Stamped: 2026-11-28.

Evidence published: 2012–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults having open or laparoscopic abdominal (and other clean-contaminated) surgery, does a wound-edge protector reduce surgical-site infection versus no protector, and do dual-ring devices outperform single-ring devices?

Balance of the evidence

This is the natural SPLIT the slate predicted. Three syntheses of mostly small, older trials — all at considerable risk of bias in one review's assessment — pool to relative risk ratios of 0.55–0.65 for surgical-site infection, with dual-ring devices looking better than single-ring in subgroup analyses (0.29–0.31 vs 0.71–0.83), a contrast one synthesis explicitly warns may reflect poorer double-ring data. The ROSSINI trial, the large multicentre randomised trial with blinded outcome assessment, found 24.7% versus 25.4% — the treatment made no difference. Devices are named by design only: the carded records do not give brands. SPLIT.

MeSH: Abdomen/surgery · Aged · Confidence Intervals · Humans · Length of Stay · Middle Aged · Odds Ratio · Plastics · Quality of Life · Single-Blind Method · Surgical Drapes · Surgical Wound Infection/prevention & control

Cards (5)

Card 1 — Pinkney 2013 — ROSSINI (multicentre RCT, 760 patients): wound-edge protection made no difference to surgical-site infection — 24.7% with the device versus 25.4% without (the treatment made no difference)

Study: Multicentre randomised controlled trial (ROSSINI, Pinkney 2013)

Population: 760 patients undergoing laparotomy at 21 UK hospitals, randomised to standard care or a wound-edge protection device during surgery; surgical-site infection within 30 days was assessed by blinded clinicians and patient self-report. 735 patients were analysed for the primary outcome.

Summary: Pinkney 2013 — ROSSINI (multicentre RCT, 760 patients): wound-edge protection made no difference to surgical-site infection — 24.7% with the device versus 25.4% without (the treatment made no difference)

Result: Surgical-site infection occurred in 91 of 369 patients (24.7%) in the device group and 93 of 366 (25.4%) in the control group (odds ratio 0.97, 95% CI 0.69 to 1.36; P = 0.85). The lack of benefit was consistent across clinician and patient assessments and all secondary outcomes, including quality of life and hospital stay.

Watch out: The largest and most rigorous trial in this base, and it is null — it outweighs the smaller positive trials in the meta-analyses below. The record does not name the specific device brand used.

Source: Pinkney TD et al. Impact of wound edge protection devices on surgical site infection after laparotomy: multicentre randomised controlled trial (ROSSINI Trial). BMJ. 2013. PMID: 23903454. Registry ID: none in the record. MeSH: Abdomen/surgery · Aged · Confidence Intervals · Humans · Length of Stay · Middle Aged · Odds Ratio · Plastics · Quality of Life · Single-Blind Method · Surgical Drapes · Surgical Wound Infection/prevention & control

Card 2 — Gheorghe 2012 (systematic review, 12 studies, 1,933 patients): pooled risk ratio 0.60 favoured wound-edge protection — but every included study was at considerable risk of bias

Study: Systematic review/meta-analysis (Gheorghe 2012)

Population: Twelve studies reporting primary data (1,933 patients) on wound-edge protection devices versus standard care in open abdominal surgery, reviewed to Cochrane principles.

Summary: Gheorghe 2012 (systematic review, 12 studies, 1,933 patients): pooled risk ratio 0.60 favoured wound-edge protection — but every included study was at considerable risk of bias

Result: An exploratory meta-analysis gave a pooled risk ratio of 0.60 (95% CI 0.41 to 0.86) for surgical-site infection — a 40% relative reduction — with no significant heterogeneity or publication bias detected. However, the quality assessment found all included studies at considerable risk of bias, and the authors called for a large, good-quality randomised trial (the call ROSSINI then answered, with a null result).

Watch out: A pooled relative effect from small, biased trials is exactly the pattern that a large rigorous trial often overturns — read this card together with ROSSINI, not instead of it.

Source: Gheorghe A et al. Systematic review of the clinical effectiveness of wound-edge protection devices in reducing surgical site infection in patients undergoing open abdominal surgery. Annals of surgery. 2012. PMID: 22270692. Registry ID: none in the record. MeSH: Abdomen/surgery · Humans · Laparotomy/instrumentation · Protective Devices · Quality Assurance, Health Care · Surgical Drapes · Surgical Wound Infection/etiology,prevention & control · Treatment Outcome · Wounds and Injuries/complications,surgery

Card 3 — Edwards 2012 (meta-analysis, 6 RCTs, 1,008 patients): wound protectors reduced infection in gastrointestinal/biliary surgery (risk ratio 0.55), driven by dual-ring devices (0.31) rather than single-ring (0.83, not significant)

Study: Meta-analysis of randomised trials (Edwards 2012)

Population: Six randomised trials (1,008 patients) of impervious wound-edge protectors in gastrointestinal and biliary tract surgery.

Summary: Edwards 2012 (meta-analysis, 6 RCTs, 1,008 patients): wound protectors reduced infection in gastrointestinal/biliary surgery (risk ratio 0.55), driven by dual-ring devices (0.31) rather than single-ring (0.83, not significant)

Result: Wound protector use was associated with a significantly lower surgical-site infection rate (risk ratio 0.55, 95% CI 0.31 to 0.98; P = 0.04) — a relative measure; the record does not give a single pooled absolute rate. By device design, dual-ring protectors showed a stronger effect (RR 0.31, 95% CI 0.14 to 0.67; P = 0.003) than single-ring protectors (RR 0.83, 95% CI 0.38 to 1.83; P = 0.64, not significant). Publication year significantly influenced the pooled result.

Watch out: Only six small trials, and the dual-ring/single-ring contrast is a between-trial subgroup comparison — device type is confounded with trial era and quality.

Source: Edwards JP et al. Wound protectors reduce surgical site infection: a meta-analysis of randomized controlled trials. International journal of surgery. 2012. PMID: 22584694. Registry ID: none in the record. MeSH: Biliary Tract Surgical Procedures · Digestive System Surgical Procedures · Equipment Design · Humans · Protective Devices · Randomized Controlled Trials as Topic · Surgical Drapes · Surgical Wound Infection/prevention & control

Card 4 — Mihaljevic 2015 (systematic review/meta-analysis, 16 RCTs, 3,695 patients): protectors reduced infection overall (risk ratio 0.65), with double-ring devices at 0.29 versus single-ring at 0.71 — a subgroup the authors flag may reflect poorer double-ring data quality

Study: Systematic review/meta-analysis of RCTs (Mihaljevic 2015)

Population: 16 randomised trials (3,695 patients, 1972–2014) of wound-edge protectors in patients undergoing laparotomy, with critical appraisal that found methodological flaws, predominantly in the older trials.

Summary: Mihaljevic 2015 (systematic review/meta-analysis, 16 RCTs, 3,695 patients): protectors reduced infection overall (risk ratio 0.65), with double-ring devices at 0.29 versus single-ring at 0.71 — a subgroup the authors flag may reflect poorer double-ring data quality

Result: Wound-edge protectors significantly reduced surgical-site infection (risk ratio 0.65, 95% CI 0.51 to 0.83; p = 0.0007; I² = 52%), with a similar effect in colorectal surgery (RR 0.65). Double-ring devices showed a greater protective effect (RR 0.29, 95% CI 0.15 to 0.55) than single-ring devices (RR 0.71, 95% CI 0.54 to 0.92) — but the authors note this might largely be due to the lower quality of the available double-ring data. Effects were larger in contaminated cases (RR 0.44) than clean-contaminated (RR 0.72), and for superficial infections (RR 0.45).

Watch out: This pooling includes the era of trials ROSSINI was designed to supersede; whether ROSSINI's own data are inside the 16 trials matters and the record's trial list is not reproduced here — the split with ROSSINI is therefore presented, not resolved.

Source: Mihaljevic AL et al. Wound edge protectors in open abdominal surgery to reduce surgical site infections: a systematic review and meta-analysis. PloS one. 2015. PMID: 25816365. Registry ID: none in the record. MeSH: Abdomen/pathology,surgery · Abdominal Wound Closure Techniques · Digestive System Surgical Procedures/methods · Humans · Laparotomy · Surgical Wound Infection/pathology,prevention & control

Card 5 — Synthesis: meta-analyses of small trials say protectors cut infections by about a third relative; the one large rigorous trial found 24.7% versus 25.4% — a textbook split

Study: Synthesis

Population: One large multicentre RCT (760 patients) and three meta-analyses/systematic reviews (1,008–3,695 patients) dominated by smaller, older trials at considerable risk of bias.

Summary: Synthesis: meta-analyses of small trials say protectors cut infections by about a third relative; the one large rigorous trial found 24.7% versus 25.4% — a textbook split

Result: The pooled relative effects favour protectors (risk ratios 0.55–0.65 overall; double-ring subgroups 0.29–0.31 versus single-ring 0.71–0.83), while ROSSINI — the largest, blinded-outcome trial — found no difference at all. Whether dual-ring devices genuinely outperform single-ring devices is suggested by two subgroup analyses and undermined by the data-quality caveat in one of them. SPLIT.

Watch out: Tested devices are identified in the carded records only by design (single-ring versus dual-ring impervious protectors), not by brand — no brand claim is made on this shelf.