Pure-tone hearing thresholds with age: the ISO 7029 curves climb fastest at high frequencies and faster in men — and longitudinal decline starts earlier than cross-sectional curves suggest
Shelf #6950 · Eyes, skin, nose & allergy
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1983–2004.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what do pure-tone hearing thresholds do with age — the ISO 7029 median threshold-versus-age curves by frequency and sex, and what did the longitudinal (Baltimore) measurements show about within-person decline rates versus cross-sectional estimates?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED — for the age course of pure-tone thresholds as standardised in ISO 7029 and measured in the carded human cohorts, framed by Ganong / Boron & Boulpaep (audition). Three concordant limbs: (1) the cross-sectional shape — thresholds rise with age, steepest at high frequencies, men poorer than women (Framingham, N = 1,662; the Robinson unscreened-population companion analysis, which found the 'pathological overlay' of an unscreened population equivalent to accelerated ageing); (2) the longitudinal correction — in the Baltimore Longitudinal Study of Aging (681 men, 416 women, screened), within-person decline was detectable in men by age 30 and ran more than twice as fast in men as in women, while learning effects bias cross-sectional and short-term estimates, so cross-sectional curves and true within-person decline are different quantities; (3) the standard's own limits — a Norwegian validation (232 sampled, 60 otologically normal) found the ISO female low-frequency coefficient may be set too low and the otologically-normal screen inconsistent after age 60. Exact decibel cells of the ISO 7029 tables are the standard's account, not re-derived from the fetched records, and the shelf says so on its Synthesis card. This shelf is about normative thresholds; the hearing treatment and device shelves ask different questions.
MeSH: Audiometry, Pure-Tone · Auditory Threshold · Presbycusis · Sex Factors · Longitudinal Studies · Humans
Cards (5)
Card 1 — Pearson 1995 (Baltimore Longitudinal Study of Aging): within-person hearing decline is detectable in men by age 30, runs more than twice as fast in men as in women, and is highly variable even in a screened, low-noise group (681 men, 416 women)
Study: Human longitudinal cohort study (pure-tone audiometry, BLSA), J Acoust Soc Am 1995
Population: 681 men and 416 women in the Baltimore Longitudinal Study of Aging, screened to exclude otological disease, unilateral loss and noise-induced loss, followed since 1965 with pulsed-tone tracking thresholds from 500 to 8000 Hz; longitudinal patterns estimated with mixed-effects regression models.
Summary: Pearson 1995 (Baltimore Longitudinal Study of Aging): within-person hearing decline is detectable in men by age 30, runs more than twice as fast in men as in women, and is highly variable even in a screened, low-noise group (681 men, 416 women)
Result: Hearing sensitivity declined more than twice as fast in men as in women at most ages and frequencies. Longitudinal decline was detectable at all frequencies among men by age 30; in women the age of onset was later and varied by frequency. Women were more sensitive than men above 1000 Hz, men more sensitive at lower frequencies. Learning effects biased cross-sectional and short-term longitudinal estimates, and levels and rates of change were highly variable even in this selected group — age-associated loss occurs even with relatively low-noise occupations and no evidence of noise-induced loss.
Watch out: A screened, relatively low-noise volunteer cohort — its rates are a cleaner ageing signal than population rates, not a prediction for an unscreened individual.
Source: Pearson JD, Morrell CH, Gordon-Salant S, Brant LJ, et al. Gender differences in a longitudinal study of age-associated hearing loss. The Journal of the Acoustical Society of America. 1995. PMID: 7876442. Registry ID: none in the record. MeSH: Adult · Aged · Audiometry, Pure-Tone · Female · Humans · Longitudinal Studies · Male · Middle Aged · Noise · Presbycusis · Sex Factors
Card 2 — Gates 1990 (Framingham): in 1,662 people in their 60s–90s, pure-tone thresholds rose with age and men had poorer sensitivity than women, while middle-ear measures did not change with age or sex
Study: Human population cohort study (audiometry, Framingham), Ear Hear 1990
Population: 1,662 men and women of the Framingham cohort in their 60th through 90th decades, tested at biennial exam 18 (1983–1985) with a hearing questionnaire, pure-tone sensitivity, acoustic compliance measures and word-recognition testing.
Summary: Gates 1990 (Framingham): in 1,662 people in their 60s–90s, pure-tone thresholds rose with age and men had poorer sensitivity than women, while middle-ear measures did not change with age or sex
Result: Pure-tone thresholds increased with age; the rate of change with age did not differ by gender even though men had poorer threshold sensitivity. Maximum word recognition declined with age more rapidly in men and was poorer in men at all ages. Acoustic compliance and middle-ear pressure did not vary with gender or age, pointing to a sensorineural rather than conductive basis for the age gradient. Hearing aids were being used by only 10% of subjects likely to benefit from amplification.
Watch out: Cross-sectional within one exam cycle: cohort and era effects (including past noise exposure) are folded into its age gradient — the contrast with the longitudinal Baltimore card is the point of this shelf.
Source: Gates GA, Cooper JC, Kannel WB, Miller NJ. Hearing in the elderly: the Framingham cohort, 1983-1985. Part I. Basic audiometric test results. Ear and Hearing. 1990. PMID: 2210098. Registry ID: none in the record. MeSH: Acoustic Impedance Tests · Aged · Aged, 80 and over · Aging · Audiometry · Cohort Studies · Female · Hearing Aids · Humans · Male · Middle Aged · Presbycusis · Sex Factors
Card 3 — Robinson 1988: the unscreened-population companion to ISO 7029 — typical thresholds converge with the otologically-normal standard at the extremes, and the 'pathological overlay' behaves like accelerated ageing
Study: Human normative-data synthesis (audiometric reference values), Br J Audiol 1988
Population: A critical analysis of published threshold-versus-age material for the typical unscreened population, presented in companion form to ISO 7029, whose screened ('otologically normal') curves rest on Robinson and Sutton (1978). No single new cohort N is printed in the record — it is a normative-data synthesis of published studies.
Summary: Robinson 1988: the unscreened-population companion to ISO 7029 — typical thresholds converge with the otologically-normal standard at the extremes, and the 'pathological overlay' behaves like accelerated ageing
Result: The unscreened-population distributions converged closely to ISO 7029 at the extremity of the distributions, and showed striking uniformity of form among apparently discordant studies. The adventitious hearing loss carried by an unscreened population — the so-called 'pathological overlay' — was essentially equivalent to accelerated ageing. The practical consequence the record draws: comparing a noise-exposed worker against an age-matched otologically-normal baseline attributes that overlay to noise, which is why the unscreened companion curves exist.
Watch out: A synthesis of published datasets, not a primary cohort — carded as the documentary basis of the ISO 7029 framework this shelf is about, and labelled as such.
Source: Robinson DW. Threshold of hearing as a function of age and sex for the typical unscreened population. British Journal of Audiology. 1988. PMID: 3365524. Registry ID: none in the record (pre-registration era). MeSH: Adolescent · Adult · Age Factors · Aged · Audiometry, Pure-Tone · Auditory Threshold · Female · Hearing Loss, Noise-Induced · Hearing Loss, Sensorineural · Humans · Male · Middle Aged · Presbycusis · Reference Values · Sex Factors · Vestibulocochlear Nerve
Card 4 — Stenklev & Laukli 2004: tested against ISO 7029, the standard's female coefficient may be set too low at low frequencies, and its 'otologically normal' screening separates inconsistently after age 60 (232 sampled, 60 otologically normal)
Study: Human audiometric study (normative-standard validation), Int J Audiol 2004
Population: A random sample of 232 elderly Norwegian subjects given a battery including pure-tone audiometry in the conventional and extended high-frequency ranges, compared against the ISO 7029 normative distributions; 60 otologically normal (ON) subjects were selected for comparative analysis.
Summary: Stenklev & Laukli 2004: tested against ISO 7029, the standard's female coefficient may be set too low at low frequencies, and its 'otologically normal' screening separates inconsistently after age 60 (232 sampled, 60 otologically normal)
Result: After mathematical transformation of the threshold data, the ISO 7029 normative alpha coefficient in females appeared set too low compared with this sample at the lower frequencies, leading to an underestimation of hearing thresholds in ON females. In the ON sample, thresholds deteriorated with age in the extended high-frequency range; no gender threshold differences were found there, although unmeasurable responses were more prevalent in males at some frequencies. Threshold differences between ON and unscreened subjects were not consistent at any frequency, so the ON screening criteria in ISO 7029 may be unreliable in subjects over 60 years.
Watch out: One national sample measured against the standard — it qualifies ISO 7029 at the edges (older ages, female low frequencies) rather than overturning the curves.
Source: Stenklev NC, Laukli E. Presbyacusis-hearing thresholds and the ISO 7029. International Journal of Audiology. 2004. PMID: 15357413. Registry ID: none in the record. MeSH: Age Factors · Aged · Aged, 80 and over · Aging · Audiometry, Pure-Tone · Audiometry, Speech · Auditory Threshold · Female · Humans · Male · Middle Aged · Norway · Presbycusis · Prevalence · Prospective Studies · Sex Distribution
Card 5 — Synthesis: thresholds climb with age, fastest at high frequencies and faster in men — and the cross-sectional curves and the longitudinal record tell measurably different stories
Study: Synthesis
Population: Synthesis of the four carded records above (the Baltimore longitudinal programme, the Framingham cohort, the Robinson unscreened-population companion analysis, and the Norwegian ISO 7029 validation), framed by the Ganong / Boron & Boulpaep account of audition.
Summary: Synthesis: thresholds climb with age, fastest at high frequencies and faster in men — and the cross-sectional curves and the longitudinal record tell measurably different stories
Result: The settled shape, as the textbook (Ganong / Boron & Boulpaep) presents it and the carded human data support: pure-tone thresholds rise progressively with age, the rise is steepest at the highest frequencies, and men carry poorer thresholds than women through most of adult life. The longitudinal Baltimore record adds what cross-sectional curves cannot: within-person decline in men is already detectable by age 30, proceeds more than twice as fast as in women, and cross-sectional estimates are distorted by learning effects and cohort noise history — so a median ISO 7029 curve for a decade is a population reference, not an individual's trajectory. The standard itself is not beyond measurement criticism: its female low-frequency coefficient may run low, and its otologically-normal screening separates inconsistently after 60. Exact decibel values for each decade, frequency and sex are the ISO 7029 standard's own published tables — presented here as the standard's account, since the fetched records confirm the shape, the sex difference and the longitudinal rates rather than reprinting every cell of the table.
Watch out: Population, era and screening definition move these curves materially; the shelf's numbers are reference distributions for otologically defined groups, not diagnostic cut-offs for a single patient.
Source: Synthesis of the carded records above (PMIDs 7876442, 2210098, 3365524, 15357413), with Ganong and Boron & Boulpaep textbook framing. Registry ID: none in the record. MeSH: not captured from the record