The tear film in health: basal turnover ~15%/min by fluorophotometry, break-up at ~11–12 seconds, osmolarity just under 300 mOsm/L

Shelf #6952 · Eyes, skin, nose & allergy

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1992–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, what does the tear film do — tear turnover rate by fluorophotometry, break-up time distributions, tear osmolarity ranges, and basal versus reflex secretion rates?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED — for the healthy tear film's measured behaviour, framed by Ganong / Boron & Boulpaep (lacrimal apparatus — thin framing; this shelf rests chiefly on the primary measurement literature, as its slate row directs). Turnover is the concordant limb: basal tear turnover by fluorophotometry was 15.6 ± 5.4%/min in 41 healthy controls (Kuppens & van Best) and 13.1–17.5%/min across three European centres under one standardised protocol — roughly a sixth of the film per minute. Break-up time in health centres at ~11 s by automated non-invasive measurement (N = 237) and ~12 s by fluorescein (N = 30), carded per method, never pooled. Osmolarity centres just under 300 mOsm/L (289.0 ± 5.8 in the large cohort; 299.06 ± 7.65 in young adults), with no age or sex effect on break-up time or osmolarity in the large cohort. REFUSAL: the classic Mishima 1966 tear-volume/tear-flow anchor was refused as a card — its record fetched has no abstract (reported on the Synthesis card). The dry-eye treatment shelves ask different questions.

MeSH: Tears · Fluorophotometry · Osmolar Concentration · Humans

Cards (5)

Card 1 — Kuppens & van Best 1992: basal tear turnover in healthy eyes is 15.6 ± 5.4%/min by fluorophotometry — lower in glaucoma, and lower still on timolol (41 healthy controls)

Study: Human fluorophotometry study (basal tear turnover), Invest Ophthalmol Vis Sci 1992

Population: 41 healthy control subjects, 13 open-angle glaucoma patients using no ophthalmic medication and 24 glaucoma patients using daily timolol; basal tear turnover (turnover at the lowest reflex lacrimation achievable under physiologic conditions) measured by fluorophotometry from the decay of tear fluorescence after 1 microlitre of 2% fluorescein, discarding the first 5 minutes.

Summary: Kuppens & van Best 1992: basal tear turnover in healthy eyes is 15.6 ± 5.4%/min by fluorophotometry — lower in glaucoma, and lower still on timolol (41 healthy controls)

Result: Basal tear turnover was 15.6 ± 5.4%/min in healthy controls, significantly higher than in untreated glaucoma patients (12.3 ± 4.1%/min) and in timolol-treated patients (10.1 ± 3.2%/min) (P < 0.02); the timolol group was also significantly below the untreated glaucoma group (P = 0.03). Tear-film break-up time in the timolol group was significantly shorter than in the other two groups. Health, then, is a turnover of roughly a sixth of the tear film per minute at basal (minimal-reflex) conditions.

Watch out: Basal turnover is a deliberately minimised-reflex measurement; it is not the higher turnover seen with reflex tearing, and the glaucoma/timolol limbs are disease/drug contrasts, not health values.

Source: Kuppens EV, Stolwijk TR, de Keizer RJ, van Best JA. Basal tear turnover and topical timolol in glaucoma patients and healthy controls by fluorophotometry. Investigative Ophthalmology & Visual Science. 1992. PMID: 1428718. Registry ID: none in the record (pre-registration era). MeSH: Administration, Topical · Fluorophotometry · Glaucoma · Humans · Intraocular Pressure · Reference Values · Reproducibility of Results · Tears · Timolol

Card 2 — van Best 1995 (European concerted action): with one standardised protocol, healthy basal tear turnover was 13.1–17.5%/min across three European cities — the method travels

Study: Human multicentre methods study (standardised basal tear turnover), Graefes Arch Clin Exp Ophthalmol 1995

Population: Healthy volunteers aged 20–70 years in three European cities (Clermont-Ferrand n = 4, Leiden n = 24, Madrid n = 20), measured with identical commercial fluorophotometers under a standardised protocol: 1-microlitre fluorescein drop, mono-exponential decay taken as basal tear flow. One centre contributed only 4 volunteers — printed on the face.

Summary: van Best 1995 (European concerted action): with one standardised protocol, healthy basal tear turnover was 13.1–17.5%/min across three European cities — the method travels

Result: Mean basal tear turnover was 13.1 ± 4.6%/min (Clermont-Ferrand), 16.0 ± 5.2%/min (Leiden) and 17.5 ± 3.4%/min (Madrid); the differences between cities were not significant (P > 0.09). Under one protocol, then, healthy basal turnover sits in the mid-teens percent per minute wherever it is measured — the cross-centre concordance that makes the Kuppens healthy value (15.6%/min) a reference rather than a local artefact.

Watch out: Centre Ns are uneven (4, 24, 20); the claim is concordance of means under a shared protocol, not precision at the smallest centre.

Source: van Best JA, Benitez del Castillo JM, Coulangeon LM. Measurement of basal tear turnover using a standardized protocol. European concerted action on ocular fluorometry. Graefe's Archive for Clinical and Experimental Ophthalmology. 1995. PMID: 7721117. Registry ID: none in the record (pre-registration era). MeSH: Adult · Aged · Aged, 80 and over · Aging · Europe · Eye · Female · Fluorescein · Fluoresceins · Fluorophotometry · Glaucoma, Open-Angle · Humans · Male · Middle Aged · Reference Standards · Tears

Card 3 — Singh 2022: in 237 healthy people, non-invasive break-up time averaged 10.95 ± 2.02 s, tear meniscus height 0.34 ± 0.07 mm and osmolarity 289.0 ± 5.8 mOsm/L — with no age or sex effect on break-up time or osmolarity

Study: Human normative study (automated tear-film assessment in health), Front Med 2022

Population: 237 healthy subjects (474 eyes; 150 males; mean age 40 ± 17 years, range 10–78) with no ocular disease, assessed automatically with the Keratograph 5M (OCULUS GmbH, Wetzlar, Germany — device named as published) for tear meniscus height and non-invasive tear break-up time (NIBUT), and the TearLab Osmolarity System (TearLab Corporation, California, USA — named as published) for osmolarity.

Summary: Singh 2022: in 237 healthy people, non-invasive break-up time averaged 10.95 ± 2.02 s, tear meniscus height 0.34 ± 0.07 mm and osmolarity 289.0 ± 5.8 mOsm/L — with no age or sex effect on break-up time or osmolarity

Result: Mean tear meniscus height was 0.34 ± 0.07 mm, mean NIBUT 10.95 ± 2.02 s and mean tear osmolarity 289.0 ± 5.8 mOsm/L. Age had a small positive relationship with meniscus height (0.002 mm/year, P < 0.0001) but no effect on NIBUT (P = 0.26) or osmolarity (P = 0.27); there were no sex differences in any parameter, and meniscus height, NIBUT and osmolarity were not significantly associated with each other. In health these three quantities are therefore near-independent descriptors, not interchangeable proxies.

Watch out: One population (Indian) and one device pair; NIBUT by automated keratograph is not the same measurement as fluorescein break-up time — compare the Masmali card's fluorescein TBUT of ~12 s as a neighbouring, not identical, quantity.

Source: Singh S, Srivastav S, Mohamed A, Basu S. Non-invasive Tear Film Assessment in Normal Population: Effect of Age, Sex, and Interparametric Relationship. Frontiers in Medicine. 2022. PMID: 35721069. Registry ID: none in the record. MeSH: not captured from the record

Card 4 — Masmali 2014: tear osmolarity in 30 healthy young adults averaged 299.06 ± 7.65 mOsm/L on the TearLab system, with fluorescein break-up time ~12 s and good repeatability

Study: Human normative study (tear osmolarity repeatability in health), Eye Contact Lens 2014

Population: 30 healthy young adults (13 men, 17 women; age 20–40 years, mean 28.57 ± 5.58) in Saudi Arabia with no dry-eye symptoms or ocular disease, screened with slit-lamp examination, phenol red thread, tear break-up time (TBUT) and the McMonnies questionnaire; three osmolarity measurements in one eye at 5-minute intervals with the TearLab osmometer (named as published).

Summary: Masmali 2014: tear osmolarity in 30 healthy young adults averaged 299.06 ± 7.65 mOsm/L on the TearLab system, with fluorescein break-up time ~12 s and good repeatability

Result: Overall mean tear osmolarity was 299.06 ± 7.65 mOsm/L — 50% of subjects read 299–312 mOsm/L, 40% read 288–299 and 10% read 277–288 — within the published reference range the record cites (298.0–301.9 mOsm/L). Repeated readings did not differ significantly (P = 0.945), showing good precision. Mean TBUT was 12 ± 1.7 s (right) and 12.5 ± 1.6 s (left), and phenol red thread wetting 22 ± 7.7 mm and 21.5 ± 6.6 mm; osmolarity correlated negatively with TBUT. Together with the Singh card (289.0 mOsm/L in an older, wider-age sample), healthy osmolarity centres just under 300 mOsm/L, with device and population moving the mean by about 10 mOsm/L.

Watch out: Young adults (20–40) in a hot climate, one eye, one device — a repeatability and reference-range record, not a lifespan normative cohort.

Source: Masmali A, Alrabiah S, Alharbi A, El-Hiti GA, Almubrad T. Investigation of tear osmolarity using the TearLab Osmolarity System in normal adults in Saudi Arabia. Eye & Contact Lens. 2014. PMID: 24412954. Registry ID: none in the record. MeSH: Adult · Diagnostic Techniques, Ophthalmological · Female · Humans · Male · Osmolar Concentration · Reproducibility of Results · Saudi Arabia · Tears · Young Adult

Card 5 — Synthesis: the healthy tear film turns over at roughly a sixth of its volume a minute, breaks up at about 11–12 seconds, and sits just under 300 mOsm/L

Study: Synthesis

Population: Synthesis of the four carded human records above (the two fluorophotometry turnover programmes and the two modern normative device cohorts), framed by Ganong / Boron & Boulpaep on the lacrimal apparatus — thin textbook framing, as this row's slate states: the shelf rests chiefly on the primary measurement literature.

Summary: Synthesis: the healthy tear film turns over at roughly a sixth of its volume a minute, breaks up at about 11–12 seconds, and sits just under 300 mOsm/L

Result: Turnover: basal tear turnover by fluorophotometry is 15.6 ± 5.4%/min in healthy controls in one laboratory and 13.1–17.5%/min across three European centres under one standardised protocol — a concordant mid-teens percent per minute, i.e. the basal tear film replaces roughly a sixth of itself each minute; glaucoma and timolol lower it. Stability: break-up time in health is ~11 s non-invasively (automated keratograph, N = 237) and ~12 s by fluorescein (N = 30) — neighbouring methods, similar centre. Composition: osmolarity centres at 289–299 mOsm/L depending on cohort and device, with no age or sex effect in the large cohort. REFUSAL, reported as required: Mishima and colleagues' 1966 'Determination of tear volume and tear flow', the classic fluorophotometric-era anchor named for this row, was refused as a card because its PubMed record fetched carries no abstract, so its values could not be verified from the record — it is named here, not carded, and no tear-volume figure from it is printed on this shelf. Basal versus reflex secretion rates beyond the basal-turnover definition itself are presented only as the textbook's account: the carded records measure the basal state by design, and reflex rates are not quantified in any fetched record here.

Watch out: Every quantity here is method-bound (fluorophotometry vs automated NIBUT vs lab-on-chip osmolarity); the shelf cards per method and never pools devices into one number.

Source: Synthesis of the carded records above (PMIDs 1428718, 7721117, 35721069, 24412954), with Ganong and Boron & Boulpaep textbook framing. Registry ID: none in the record. MeSH: not captured from the record