Pharyngeal critical closing pressure (Pcrit) in sleep: −13 cmH₂O in normal sleepers, climbing through zero into apnea — with loop gain and arousal threshold as the other dials
Shelf #6953 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1988–2013.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, how collapsible is the upper airway during sleep — what is the pharyngeal critical closing pressure (Pcrit) in normal sleepers versus snorers and patients with sleep apnoea, and how large are ventilatory loop gain and arousal threshold in health?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED — for Pcrit as the measured index of upper-airway collapsibility, framed by Boron & Boulpaep / Ganong and Kryger (sleep physiology). The gradient is concordant across independent preparations: in natural NREM sleep, Pcrit was −13.3 ± 3.2 cmH₂O in 7 normal subjects (Schwartz), rising to −6.5 ± 2.7 in snorers, −1.6 ± 1.4 in obstructive hypopnea and +2.5 ± 1.5 in obstructive apnea (Gleadhill) — the airway becomes self-closing as Pcrit crosses zero. In the anaesthetised, paralysed passive pharynx (Isono), velopharyngeal closing pressure showed the same ordering at higher absolute values (−3.77 ± 3.44 normal vs +0.90 and +2.78 in sleep-disordered breathing), because that preparation removes neuromuscular compensation — values are carded per protocol and never merged. The phenotyping limb (Eckert/Wellman, 75 studied) qualifies the anatomy story: OSA Pcrit averaged +0.3 vs −6.2 cmH₂O in controls, but 36% of patients had high loop gain, 37% a low arousal threshold, and 19% obstructed with a near-normal Pcrit. The OSA treatment shelves ask different questions.
MeSH: Sleep Apnea Syndromes · Pharynx · Airway Obstruction · Respiration · Sleep · Humans
Cards (5)
Card 1 — Schwartz 1988: the normal sleeping airway has a Pcrit of −13.3 ± 3.2 cmH₂O — occlusion had to be induced by driving nasal pressure below it (7 normal subjects)
Study: Human sleep physiology study (nasal pressure-drop Pcrit in health), J Appl Physiol 1988
Population: Seven normal subjects studied during non-rapid-eye-movement (NREM) sleep with varying levels of subatmospheric pressure applied through a nasal mask, relating maximal inspiratory airflow to nasal pressure. Small physiology study: N = 7 printed on the face.
Summary: Schwartz 1988: the normal sleeping airway has a Pcrit of −13.3 ± 3.2 cmH₂O — occlusion had to be induced by driving nasal pressure below it (7 normal subjects)
Result: Maximal inspiratory airflow fell in proportion to nasal pressure, and when nasal pressure fell below the critical closing pressure (Pcrit), subjects developed upper-airway occlusions terminated by arousals. In these normal sleepers the upper-airway Pcrit was −13.3 ± 3.2 (SD) cmH₂O — deeply negative, i.e. the healthy airway stays open unless upstream pressure is driven far below atmospheric. In the four subjects who stayed asleep with nasal pressure below Pcrit, recurrent occlusive apneas were demonstrated, and the Pcrit read off the airflow–pressure regression at the zero-flow intercept matched the experimentally observed value.
Watch out: N = 7, NREM sleep, one laboratory's pressure-drop protocol — the reference value for the method, not a universal constant across protocols (see the Isono card's different, anaesthetised preparation).
Source: Schwartz AR, Smith PL, Wise RA, Gold AR, Permutt S. Induction of upper airway occlusion in sleeping individuals with subatmospheric nasal pressure. Journal of Applied Physiology. 1988. PMID: 3372411. Registry ID: none in the record (pre-registration era). MeSH: Adult · Airway Obstruction · Atmospheric Pressure · Female · Humans · Male · Nasal Cavity · Respiration · Respiration, Artificial · Sleep · Sleep Apnea Syndromes
Card 2 — Gleadhill 1991: Pcrit climbs a continuum — snorers −6.5 ± 2.7, obstructive hypopnea −1.6 ± 1.4, obstructive apnea +2.5 ± 1.5 cmH₂O
Study: Human sleep physiology study (Pcrit across the snoring–apnea spectrum), Am Rev Respir Dis 1991
Population: 10 asymptomatic snorers, 6 patients with obstructive hypopneas and 10 patients with obstructive apneas, studied during NREM sleep with Pcrit derived from the relationship between maximal inspiratory airflow and nasal pressure (the Schwartz pressure-drop method).
Summary: Gleadhill 1991: Pcrit climbs a continuum — snorers −6.5 ± 2.7, obstructive hypopnea −1.6 ± 1.4, obstructive apnea +2.5 ± 1.5 cmH₂O
Result: Pcrit rose stepwise across the spectrum: −6.5 ± 2.7 cmH₂O in snorers, −1.6 ± 1.4 in obstructive hypopnea and +2.5 ± 1.5 in obstructive apnea (mean ± SD, P < 0.001) — in apnea the airway closes at a positive pressure, i.e. it closes on its own at atmospheric pressure. Higher Pcrit was associated with lower maximal inspiratory airflow during tidal breathing in sleep (P < 0.005). Small differences in collapsibility along a continuum thus separate normal snoring from hypopnea and apnea — there is no threshold jump, there is a gradient.
Watch out: Groups of 10, 6 and 10; the gradient is the finding, and its absolute values belong to this laboratory's NREM pressure-drop protocol.
Source: Gleadhill IC, Schwartz AR, Schubert N, Wise RA, Permutt S, Smith PL. Upper airway collapsibility in snorers and in patients with obstructive hypopnea and apnea. The American Review of Respiratory Disease. 1991. PMID: 2048817. Registry ID: none in the record (pre-registration era). MeSH: Airway Obstruction · Apnea · Humans · Nasal Cavity · Pulmonary Ventilation · Respiration Disorders · Respiratory System · Sleep Stages · Snoring · Tidal Volume
Card 3 — Isono 1997: in the paralysed passive pharynx, velopharyngeal closing pressure was −3.77 ± 3.44 cmH₂O in normal subjects versus +0.90 and +2.78 in sleep-disordered breathing — and the velopharynx is where the airway closes
Study: Human physiology study (passive pharynx mechanics under anaesthesia/paralysis), J Appl Physiol 1997
Population: 57 subjects under general anaesthesia with complete paralysis, divided by nocturnal oximetry into a normal group (n = 17), and two sleep-disordered-breathing groups (SDB-1, n = 18; SDB-2, n = 22), matched for age and body-mass index; the static pressure–area relationship of the passive pharynx was quantified segment by segment.
Summary: Isono 1997: in the paralysed passive pharynx, velopharyngeal closing pressure was −3.77 ± 3.44 cmH₂O in normal subjects versus +0.90 and +2.78 in sleep-disordered breathing — and the velopharynx is where the airway closes
Result: The primary closure site was the velopharynx in 49 subjects and the oropharynx in only 8, with no difference in distribution between groups. Velopharyngeal closing pressure was −3.77 ± 3.44 cmH₂O in normal subjects, significantly lower than in SDB-1 (0.90 ± 1.34) and SDB-2 (2.78 ± 2.78) (P < 0.01), and maximal velopharyngeal area was larger in normals (2.10 ± 0.85 cm²) than in SDB-1 (1.15 ± 0.46) and SDB-2 (1.06 ± 0.75). Velopharyngeal closing pressure was the only mechanical variable highly correlated with the oxygen desaturation index. The passive pharynx is thus narrower and more collapsible in sleep-apneic patients — measured here with muscle activity abolished, which is why its normal closing pressure (−3.8) sits well above the sleeping, muscle-intact Schwartz value (−13.3): protocol is part of the number.
Watch out: Anaesthetised and paralysed by design — this is the passive anatomical limb of collapsibility, deliberately stripped of the neuromuscular compensation that operates in natural sleep; do not merge its closing pressures with sleep Pcrit values.
Source: Isono S, Remmers JE, Tanaka A, Sho Y, Sato J, Nishino T. Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects. Journal of Applied Physiology. 1997. PMID: 9104871. Registry ID: none in the record. MeSH: Adult · Air Pressure · Anesthesia, General · Body Mass Index · Female · Humans · Image Processing, Computer-Assisted · Laryngoscopy · Male · Middle Aged · Oropharynx · Oximetry · Pharynx · Regression Analysis · Sleep Apnea Syndromes
Card 4 — Eckert & Wellman 2013: phenotyping 75 people — OSA airways averaged Pcrit +0.3 versus −6.2 cmH₂O in controls, but 36% of patients had high loop gain and 37% a low arousal threshold, and 19% had a fairly non-collapsible airway
Study: Human sleep physiology study (OSA trait phenotyping: Pcrit, loop gain, arousal threshold), Am J Respir Crit Care Med 2013
Population: 75 men and women with and without obstructive sleep apnea, aged 20–65, studied on three nights: polysomnography, then measurement of anatomic (passive Pcrit) and non-anatomic traits — genioglossus muscle responsiveness, arousal threshold and respiratory control stability (loop gain).
Summary: Eckert & Wellman 2013: phenotyping 75 people — OSA airways averaged Pcrit +0.3 versus −6.2 cmH₂O in controls, but 36% of patients had high loop gain and 37% a low arousal threshold, and 19% had a fairly non-collapsible airway
Result: Traits varied substantially. Overall the OSA airway was more collapsible (Pcrit 0.3 [−1.5 to 1.9] vs −6.2 [−12.4 to −3.6] cmH₂O in controls, P < 0.01), yet 19% of patients had a relatively non-collapsible airway (Pcrit −2 to −5 cmH₂O) similar to many controls — and in those patients loop gain was almost twice as high as in patients with Pcrit above −2 (−5.9 vs −3.2 in the record's signed dimensionless presentation, P = 0.01). Among patients, 36% had minimal genioglossus responsiveness, 37% a low arousal threshold, 36% high loop gain and 28% multiple non-anatomic features; the authors estimate non-anatomic traits play an important role in 56% of OSA. Collapsibility is therefore one dial among several, and in a fifth of patients it is barely abnormal at all.
Watch out: A phenotyping framework measured in a research sleep laboratory over three nights; loop-gain and arousal-threshold values are method-defined traits, not routine clinical measurements.
Source: Eckert DJ, White DP, Jordan AS, Malhotra A, Wellman A. Defining phenotypic causes of obstructive sleep apnea. Identification of novel therapeutic targets. American Journal of Respiratory and Critical Care Medicine. 2013. PMID: 23721582. Registry ID: none in the record. MeSH: Adult · Aged · Case-Control Studies · Female · Humans · Male · Middle Aged · Phenotype · Polysomnography · Respiratory Muscles · Respiratory System · Sleep Apnea, Obstructive · Young Adult
Card 5 — Synthesis: the healthy airway closes only far below atmospheric pressure; disease is Pcrit climbing through zero — with loop gain and arousal threshold deciding who actually obstructs
Study: Synthesis
Population: Synthesis of the four carded human records above (the Schwartz pressure-drop programme, the Gleadhill spectrum study, the Isono passive-pharynx programme and the Eckert/Wellman phenotyping cohort), framed by Boron & Boulpaep / Ganong on upper-airway mechanics in sleep and by Kryger's sleep-medicine account as framing.
Summary: Synthesis: the healthy airway closes only far below atmospheric pressure; disease is Pcrit climbing through zero — with loop gain and arousal threshold deciding who actually obstructs
Result: The Pcrit gradient is the settled core, concordant across two independent preparations: in natural NREM sleep the normal airway's Pcrit is deeply negative (−13.3 ± 3.2 cmH₂O), snorers sit at −6.5, hypopnea at −1.6 and apnea at +2.5 — the airway becomes self-closing as Pcrit crosses zero; in the paralysed passive pharynx the same ordering appears at higher absolute pressures (normals −3.8, disordered breathing +0.9 to +2.8 cmH₂O), because the preparation removes neuromuscular compensation — protocol is part of every Pcrit number, and this shelf never merges values across protocols. The phenotyping limb adds the modern qualification: Pcrit is one trait among several — loop gain and arousal threshold are abnormal in roughly a third of patients each, and about a fifth of patients obstruct despite a near-normal Pcrit, driven by those non-anatomic traits. Textbook framing (Boron & Boulpaep / Ganong; Kryger for the sleep context) presents the pharynx as a Starling resistor whose closing pressure is set by surrounding tissue pressure and wall compliance — the carded human measurements are that model's numbers. The OSA treatment shelves (CPAP, stimulation, myofunctional therapy) ask what to do about a collapsible airway; this shelf asks how collapsible it measurably is.
Watch out: Pcrit values are protocol-bound (natural sleep vs anaesthesia/paralysis, nasal-mask pressure drops vs static pressure–area curves); the gradient across health and disease is the portable finding, not any single absolute value.
Source: Synthesis of the carded records above (PMIDs 3372411, 2048817, 9104871, 23721582), with Boron & Boulpaep, Ganong and Kryger textbook framing. Registry ID: none in the record. MeSH: not captured from the record