SourceMed · Shelf #7057 in the ask interface

Robotic versus laparoscopic hernia repair

Shelf #7057 · Emergency & first hours

SPLIT

Stamped: 2026-11-28.

Evidence published: 2020–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults undergoing minimally invasive inguinal or ventral hernia repair, does robotic repair improve pain, recovery, recurrence or complications versus laparoscopic repair, and at what cost in operating time and resource use?

Balance of the evidence

SPLIT — the two limbs answer differently over time. Inguinal: the RIVAL randomised programme (102 patients, follow-on to 2 years) found no difference in pain, quality of life, wound events or recurrence (1 recurrence per arm at 2 years), while robotic repair took a median 75.5 versus 40.5 minutes and cost a median $3258 versus $1421. Ventral: the Houston blinded randomised trial (124 patients) found no difference in its primary outcome — days in hospital within 90 days (relative rate 0.90, 95% CI 0.37 to 2.19) — or in early complications, again with longer operating time (141 vs 77 minutes) and higher cost (adjusted difference $2767); its 2-year follow-on reported recurrence 4% robotic versus 13% laparoscopic (relative risk 0.3, 95% CI 0.06 to 1.39; not significant) and reoperation 0% versus 11% (P=0.019), which the authors themselves label hypothesis-generating. So: early outcomes and costs consistently favour laparoscopy or neutrality; a possible late durability advantage for robotic ventral repair is unconfirmed. A robotic-versus-open protocol exists with no results yet, so the open comparison is unanswered.

MeSH: Hernia, Inguinal/surgery · Hernia, Ventral/surgery · Herniorrhaphy/methods · Laparoscopy · Robotic Surgical Procedures · Treatment Outcome

Cards (5)

Card 1 — RIVAL 2020 (inguinal): robotic repair gave no pain, quality-of-life or wound advantage over laparoscopic repair, at longer operating time and higher cost

Study: Multicentre, single-blinded, randomised pilot trial (inguinal hernia)

Population: 102 patients analysed (of 113 enrolled) with unilateral primary or recurrent inguinal hernia at 6 academic sites: laparoscopic transabdominal preperitoneal repair 54 (mean age 57.2 years, 88.9% male) versus robotic transabdominal preperitoneal repair 48 (mean age 56.1 years, 91.6% male); 30-day follow-up.

Summary: RIVAL 2020 (inguinal): robotic repair gave no pain, quality-of-life or wound advantage over laparoscopic repair, at longer operating time and higher cost

Result: No differences at preoperative, 1-week or 30-day points in wound events, readmissions, pain (visual analogue scale) or quality of life (SF-36). Robotic repair took longer (median operative time 75.5 vs 40.5 minutes; P<.001), cost more (median $3258 vs $1421; P<.001) and gave surgeons higher frustration scores (NASA Task Load Index 32.7 vs 20.1; P=.004), with no ergonomic advantage.

Watch out: A pilot trial with no single primary outcome and only 30 days of follow-up — it can rule in 'no early benefit', not settle recurrence; several hernia trials in this field are device-maker-supported, and the record does not state the funder on its face.

Source: Prabhu AS et al. Robotic Inguinal vs Transabdominal Laparoscopic Inguinal Hernia Repair: The RIVAL Randomized Clinical Trial. JAMA Surg. 2020. PMID: 32186683. Registry ID: ClinicalTrials.gov: NCT02816658 , from the record's databank fields. MeSH: Abdomen · Adult · Aged · Female · Hernia, Inguinal/surgery · Herniorrhaphy/methods · Humans · Laparoscopy · Male · Middle Aged · Pilot Projects · Prospective Studies · Robotic Surgical Procedures · Single-Blind Method · Treatment Outcome

Card 2 — RIVAL 1–2-year follow-up: pain, quality of life and recurrence remained the same after robotic and laparoscopic inguinal repair (1 recurrence in each arm at 2 years)

Study: Randomised trial long-term follow-up report (inguinal hernia) — same programme as the RIVAL primary report, not an independent trial

Population: Of the 102 RIVAL patients, 83 (81%) completed 1-year follow-up (45 laparoscopic, 38 robotic) and 77 (75%) completed 2-year follow-up (43 laparoscopic, 34 robotic).

Summary: RIVAL 1–2-year follow-up: pain, quality of life and recurrence remained the same after robotic and laparoscopic inguinal repair (1 recurrence in each arm at 2 years)

Result: At 1 and 2 years pain was similar in both groups, no patient in either arm had neuropathic pain, health-related quality of life and physical activity were similar, and no long-term wound morbidity occurred. At 2 years hernia recurrence was 1 laparoscopic versus 1 robotic (P=1.0).

Watch out: A quarter of patients were lost by 2 years and recurrence counts of one per arm cannot distinguish the approaches; this is a follow-on report of the same trial, not a second trial.

Source: Miller BT et al. Laparoscopic versus robotic inguinal hernia repair: 1- and 2-year outcomes from the RIVAL trial. Surg Endosc. 2023. PMID: 35578051. Registry ID: none in the record's databank fields. MeSH: Humans · Robotic Surgical Procedures · Hernia, Inguinal/surgery · Quality of Life · Herniorrhaphy · Laparoscopy · Neuralgia/surgery · Surgical Mesh

Card 3 — Olavarria 2020 (ventral): robotic repair did not reduce days in hospital within 90 days versus laparoscopic repair, and cost more with longer operating time

Study: Pragmatic, multicentre, blinded randomised trial (ventral hernia)

Population: 124 patients deemed appropriate candidates for elective minimally invasive ventral hernia repair at Houston hernia clinics, randomised to robotic repair (65) or laparoscopic repair (59); 90-day follow-up completed in 123 (99%).

Summary: Olavarria 2020 (ventral): robotic repair did not reduce days in hospital within 90 days versus laparoscopic repair, and cost more with longer operating time

Result: No difference in the primary outcome, days in hospital within 90 days (median 0 vs 0 days; relative rate 0.90, 95% CI 0.37 to 2.19; P=0.82), nor in emergency visits, wound complications, recurrence or reoperation. Robotic repair took longer (141 vs 77 minutes; mean difference 62.89 minutes, 95% CI 45.75 to 80.01) and cost more ($15,865 vs $12,955; adjusted absolute difference $2767, 95% CI $910 to $4626; P=0.004). Two enterotomies occurred with robotic repair versus none with laparoscopic repair, and median 1-month abdominal-wall quality-of-life improvement was 3 points robotic versus 15 laparoscopic.

Watch out: A single-region pragmatic trial of intraperitoneal onlay mesh repair; the quality-of-life gap at 1 month and the two enterotomies are secondary signals in a 124-patient trial, not settled harms.

Source: Olavarria OA et al. Robotic versus laparoscopic ventral hernia repair: multicenter, blinded randomized controlled trial. BMJ. 2020. PMID: 32665218. Registry ID: ClinicalTrials.gov: NCT03490266 , from the record's databank fields. MeSH: Emergency Service, Hospital · Hernia, Ventral/surgery · Herniorrhaphy/adverse effects/economics/methods · Hospital Costs · Humans · Laparoscopy/adverse effects/economics · Length of Stay · Operative Time · Postoperative Complications · Quality of Life · Recurrence · Reoperation · Robotic Surgical Procedures/adverse effects/economics

Estimate type: adjusted estimate, as stated in the card.

Card 4 — Ventral trial 2-year report: recurrence 4% robotic versus 13% laparoscopic and reoperation 0% versus 11% — a hypothesis-generating late signal from the same trial

Study: Randomised trial 2-year follow-up report (ventral hernia) — same programme as the Olavarria primary report, not an independent trial

Population: Of 124 randomised patients, 101 completed 2-year follow-up (54 of 65 robotic, 83%; 47 of 59 laparoscopic, 80%).

Summary: Ventral trial 2-year report: recurrence 4% robotic versus 13% laparoscopic and reoperation 0% versus 11% — a hypothesis-generating late signal from the same trial

Result: No differences in surgical-site infection or surgical-site occurrence. Hernia recurrence occurred in 2 patients (4%) after robotic repair versus 6 (13%) after laparoscopic repair (relative risk 0.3, 95% CI 0.06 to 1.39; P=0.12 — not significant). No robotic patient (0%) required reoperation versus 5 laparoscopic patients (11%; P=0.019). The authors call these findings hypothesis-generating and ask for larger multicentre trials with longer follow-up.

Watch out: The recurrence difference is not statistically significant and rests on 8 events after ~18% attrition; the significant reoperation contrast (0 vs 5) is fragile to a single event changing arms.

Source: Dhanani NH et al. Robotic Versus Laparoscopic Ventral Hernia Repair: Two-Year Results From a Prospective, Multicenter, Blinded Randomized Clinical Trial. Ann Surg. 2023. PMID: 37203558. Registry ID: ClinicalTrials.gov: NCT03490266 , from the record's databank fields. MeSH: Humans · Robotic Surgical Procedures · Prospective Studies · Robotics · Laparoscopy/methods · Hernia, Ventral/surgery · Herniorrhaphy/methods · Surgical Wound Infection/epidemiology · Surgical Mesh

Card 5 — Synthesis: no early benefit in either limb; the only pro-robotic signal is a late, fragile one in a single ventral trial

Study: Synthesis

Population: Two randomised programmes: RIVAL (102 patients, inguinal, with 1–2-year follow-on) and the Houston ventral trial (124 patients, with 2-year follow-on). A robotic-versus-open ventral protocol (the Robovent trial) has been published as a protocol with no results in its record, so it contributes no evidence here.

Summary: Synthesis: no early benefit in either limb; the only pro-robotic signal is a late, fragile one in a single ventral trial

Result: Inguinal limb: no difference in pain, quality of life, wound events or 2-year recurrence, with robotic repair slower and more expensive. Ventral limb: no difference in the primary outcome (hospital days within 90 days) or in early complications, again slower and more expensive; at 2 years recurrence and reoperation numerically favoured robotic repair without a significant recurrence difference. Across both limbs the consistent, replicated findings are longer operating time and higher cost for the robot.

Watch out: Do not read the 2-year ventral signal as established benefit: it comes from one trial, few events and incomplete follow-up. Equally, these trials enrolled straightforward elective cases operated on by experienced minimally invasive surgeons — they do not answer complex or large hernias.

Source: Synthesis of the cards above; no additional source.