Lung clearance index: ~6.2 in healthy children (upper limit 7.0-7.9 by method), flat through school age, then rising with adult age to a mean of 8.8 by age 90 — repeatable within about 5%
Shelf #7068 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2009–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what is the lung clearance index (and related multiple-breath washout indices) by age — the Global Lung Function Initiative reference values for nitrogen and SF6 washout — and how repeatable is LCI within a person?
Balance of the evidence
Textbook framing (Guyton & Hall Textbook of Medical Physiology; Boron & Boulpaep Medical Physiology): even in healthy lungs, ventilation is not perfectly uniform, and the multiple-breath washout quantifies that heterogeneity — the lung clearance index (LCI) is the number of functional residual capacity (FRC) turnovers needed to wash an inert tracer gas (resident nitrogen, or inhaled sulfur hexafluoride, SF6) down to 1/40 of its starting concentration, so a higher LCI means more uneven ventilation. The fetched human data give the scale. In healthy children the index sits near 6: Fuchs 2009 measured mean LCI 6.2 (SD 0.4) with an upper limit of normal of 7.0 on the EasyOne Pro ultrasonic system, with within-test repeatability of 5.1% and short- and long-term reproducibility of 4.2-5.1% — the test is stable within a person. The school-age nitrogen-washout norms (Anagnostopoulou 2020, Exhalyzer D) set a fixed upper limit of 7.91 for LCI at the 2.5% endpoint, because the age rise across 6-18 years was negligible (0.04 units per year). In adults the picture changes: with SF6, Trinkmann 2021 found age explained 47% of LCI variance, mean LCI rising from 6.3 (upper limit 7.4) at age 20 to 8.8 (upper limit 9.9) at age 90. The Global Lung Function Initiative equations (Ramsey 2024; 1,579 unique healthy observations, ages 2-81) pool the field: LCI prediction needs age alone, FRC needs height, age and sex, and — at the level of the prediction equations — equipment type, tracer gas and dead space did not significantly change the equations. The device-specific upper limits on the cards below (7.0 vs 7.91 vs age-dependent SF6 limits) are therefore not a contradiction of the GLI pooling but its practical boundary: interpret a patient's LCI against the reference set for their method and age. PHYSIOLOGY — ESTABLISHED.
MeSH: Humans · Male · Female · Reference Values · Aged · Middle Aged · Adult · Functional Residual Capacity/physiology · Aged, 80 and over · Young Adult · Adolescent · Child · Respiratory Function Tests/standards/instrumentation · Lung/physiology · Child, Preschool · Healthy Volunteers · Breath Tests/instrumentation/methods · Tidal Volume/physiology · Equipment Design · Lung Diseases/diagnosis · Prospective Studies · Reproducibility of Results · Breath Tests · Functional Residual Capacity · Lung · Respiratory Function Tests · Schools · Switzerland · Age Factors · Anthropometry · Cross-Sectional Studies · Lung Diseases, Obstructive/physiopathology · Smokers · Sulfur Hexafluoride/analysis
Cards (5)
Card 1 — Global Lung Function Initiative reference equations: 1,579 healthy observations, ages 2-81 — LCI predicted by age alone, FRC by height, age and sex (Ramsey 2024)
Study: Primary human physiology study (international reference-equation programme)
Population: Multiple-breath washout data from healthy individuals collated from 23 sites (3,647 test occasions); reference equations derived from 1,579 unique observations from participants aged 2-81 years, re-analysed with the latest software versions.
Summary: Global Lung Function Initiative reference equations: 1,579 healthy observations, ages 2-81 — LCI predicted by age alone, FRC by height, age and sex (Ramsey 2024)
Result: Reference equations for lung clearance index and functional residual capacity were derived with the lambda-mu-sigma method (generalised additive models of location, scale and shape). Reference equations for LCI include age as the only predictor, whereas sex-specific reference equations for FRC included height and age. Equipment type, inert tracer gas and equipment dead space volume did not significantly affect the prediction equations for either LCI or FRC.
Watch out: The abstract states the equations' structure, not numeric LCI values at each age — the numeric norms on this shelf come from the device- and age-specific studies below; a pooled equation that is statistically insensitive to equipment does not abolish the different upper limits those studies report.
Source: Ramsey KA et al. The European respiratory journal. 2024. PMID: 39326920. Registry ID: none in the record. MeSH: Humans · Male · Female · Reference Values · Aged · Middle Aged · Adult · Functional Residual Capacity/physiology · Aged, 80 and over · Young Adult · Adolescent · Child · Respiratory Function Tests/standards/instrumentation · Lung/physiology · Child, Preschool · Healthy Volunteers · Breath Tests/instrumentation/methods · Tidal Volume/physiology
Card 2 — Healthy children: mean LCI 6.2 (SD 0.4), upper limit of normal 7.0 — and the index barely moves on retesting (5.1% within-test, 4.2% at 1 hour, 5.1% at 6-15 months) (Fuchs 2009)
Study: Primary human physiology study (normative values and repeatability in children/adolescents)
Population: 44 healthy volunteers aged 5.3-20.3 years tested with nitrogen multiple-breath washout using the sidestream ultrasonic flow sensor (EasyOne Pro MBW Module, ndd Medical Technologies); 22 retested after 1 hour and 34 retested 6-15 months later.
Summary: Healthy children: mean LCI 6.2 (SD 0.4), upper limit of normal 7.0 — and the index barely moves on retesting (5.1% within-test, 4.2% at 1 hour, 5.1% at 6-15 months) (Fuchs 2009)
Result: Mean LCI (SD) was 6.2 (0.4) at the first test, 6.3 (0.4) at the second (1 hour later) and 6.0 (0.4) at follow-up 6-15 months later; the upper limit of normal was 7.0 for all subjects. Within-test repeatability was 5.1%. Short-term reproducibility was 4.2% with a mean difference of -0.13 (95% CI -0.350 to 0.087); long-term reproducibility was 5.1%. The authors conclude the low within- and between-test variability demonstrates the reliability of the equipment, protocol and technique.
Watch out: Device-specific norms (EasyOne Pro ultrasonic sensor): the upper limit of 7.0 belongs to this system and age range and should not be transplanted to other devices or to older adults, in whom LCI rises with age (see the SF6 adult study).
Source: Fuchs SI et al. Pediatric pulmonology. 2009. PMID: 19911370. Registry ID: none in the record. MeSH: Adolescent · Child · Equipment Design · Female · Humans · Lung Diseases/diagnosis · Male · Prospective Studies · Reference Values · Reproducibility of Results · Young Adult
Card 3 — Nitrogen washout in school-age children (N = 180): upper limits fixed at 7.91 (LCI 2.5%) and 5.73 (LCI 5%) because the age rise was negligible — 0.04 units per year (Anagnostopoulou 2020)
Study: Primary human physiology study (normative nitrogen-washout data, school-aged children)
Population: 180 healthy Caucasian children aged 6-18 years from four experienced centres (485 trials analysed); nitrogen multiple-breath washout on an ultrasonic flowmeter (Exhalyzer D, Eco Medics AG), analysed with Spiroware version 3.2.1.
Summary: Nitrogen washout in school-age children (N = 180): upper limits fixed at 7.91 (LCI 2.5%) and 5.73 (LCI 5%) because the age rise was negligible — 0.04 units per year (Anagnostopoulou 2020)
Result: While LCI increased with age, the increase was negligible (0.04 units per year for LCI at the 2.5% endpoint), so fixed upper limits of normal were defined for this age group: 7.91 for LCI2.5%, 5.73 for LCI5%, 1.75 for the moment ratio M1/M0 and 6.15 for M2/M0. Height and weight were independent predictors of functional residual capacity, for which a prediction equation was generated.
Watch out: Method-specific values: nitrogen washout on the Exhalyzer D gives a higher upper limit (7.91) than the EasyOne Pro paediatric study (7.0) — gas, device and software generation must match the reference set used, exactly the per-method caution this shelf is built around.
Source: Anagnostopoulou P et al. The European respiratory journal. 2020. PMID: 31862765. Registry ID: none in the record. MeSH: Adolescent · Breath Tests · Child · Functional Residual Capacity · Humans · Lung · Respiratory Function Tests · Schools · Switzerland
Card 4 — SF6 washout in adults (N = 100, ages 20-88): age drives LCI — mean 6.3 (upper limit 7.4) at age 20 rising to 8.8 (upper limit 9.9) at age 90 (Trinkmann 2021)
Study: Primary human physiology study (SF6 washout reference values across adult age)
Population: 100 pulmonary-healthy adults (never-smokers and smokers; mean age 51 years, SD 20, range 20-88) undergoing triplicate sulfur hexafluoride multiple-breath washout; LCI, acinar (Sacin) and conductive (Scond) heterogeneity derived at the 2.5% and 5% stopping points; upper limit of normal defined as the 95th percentile.
Summary: SF6 washout in adults (N = 100, ages 20-88): age drives LCI — mean 6.3 (upper limit 7.4) at age 20 rising to 8.8 (upper limit 9.9) at age 90 (Trinkmann 2021)
Result: Age was the only meaningful parameter influencing SF6 washout parameters, explaining 47% (95% CI 33% to 59%) of the variance in LCI, 32% (18% to 47%) in Sacin and 10% (2% to 22%) in Scond. Mean LCI increased from 6.3 (upper limit 7.4) to 8.8 (upper limit 9.9) between ages 20 and 90 years. Smoking accounted for only 2% (0% to 8%) of LCI variability, and no influence of height, weight or sex was seen.
Watch out: SF6 (inhaled tracer) values in adults are not interchangeable with nitrogen (resident gas) values in children: the adult age rise means a single paediatric-style upper limit near 7 would mislabel healthy older adults as abnormal.
Source: Trinkmann F et al. Thorax. 2021. PMID: 33593931. Registry ID: NCT04099225. MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Anthropometry · Breath Tests · Cross-Sectional Studies · Female · Healthy Volunteers · Humans · Lung Diseases, Obstructive/physiopathology · Male · Middle Aged · Reference Values · Respiratory Function Tests · Smokers · Sulfur Hexafluoride/analysis
Card 5 — Synthesis: healthy LCI is ~6 in childhood with an upper limit near 7-8 depending on method, stays flat through school age, then climbs with adult age to ~8.8 by age 90 — and repeats within ~5% in the same person
Study: Synthesis
Population: Synthesis of the four primary human studies above.
Summary: Synthesis: healthy LCI is ~6 in childhood with an upper limit near 7-8 depending on method, stays flat through school age, then climbs with adult age to ~8.8 by age 90 — and repeats within ~5% in the same person
Result: The concordant account, framed by the textbooks (Guyton & Hall; Boron & Boulpaep) as a measure of ventilation heterogeneity: a healthy child's lung clears tracer in about six FRC turnovers (mean LCI 6.2, SD 0.4; Fuchs 2009), the school-age rise is negligible (0.04 units/year; Anagnostopoulou 2020), and the adult rise is the dominant fact (age explaining 47% of variance; mean 6.3 at 20 years to 8.8 at 90 years on SF6; Trinkmann 2021). Upper limits are method-bound: 7.0 (EasyOne Pro, children), 7.91 at the 2.5% endpoint (nitrogen, Exhalyzer D, school age), and age-dependent on SF6 (7.4 at 20 years, 9.9 at 90 years). The GLI equations (Ramsey 2024) unify reporting — LCI from age alone, FRC from height, age and sex — without erasing those method-specific limits. Within a person the measurement is tight (repeatability/reproducibility ~4-5%), so a change well beyond ~5% is signal, not noise. PHYSIOLOGY — ESTABLISHED.
Watch out: LCI values across gases (nitrogen vs SF6), devices and software versions are cousins, not twins: longitudinal follow-up of a patient should stay on one system, and cross-system comparisons should use each system's own reference equations.
Source: Synthesis of Ramsey KA et al. The European respiratory journal. 2024 (PMID: 39326920); Fuchs SI et al. Pediatric pulmonology. 2009 (PMID: 19911370); Anagnostopoulou P et al. The European respiratory journal. 2020 (PMID: 31862765); Trinkmann F et al. Thorax. 2021 (PMID: 33593931). Textbook framing: Guyton & Hall Textbook of Medical Physiology; Boron & Boulpaep Medical Physiology.