SourceMed · Shelf #7079 in the ask interface
FRIEND reference standards for peak oxygen uptake: treadmill medians fall from 48.0 (men) and 37.6 (women) mL/kg/min in the twenties to 24.4 and 18.3 in the seventies, with cycle values systematically lower
Shelf #7079 · Heart, vessels, blood pressure & clotting
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2015–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what are reference percentile values for peak oxygen uptake (VO2peak) by age, sex and exercise mode — the FRIEND registry standards for treadmill and cycle ergometry — and how fast does VO2peak fall per decade in each sex?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED. Framed by Boron & Boulpaep Medical Physiology (textbook framing, not evidence). This shelf answers the measurement question — population percentile standards for peak oxygen uptake — which is a different question from the determinants question homed on the existing VO2max-limits shelf (what limits maximal oxygen uptake: cardiac output versus peripheral extraction); that shelf is cross-pointed here in prose only, and none of its studies is re-carded. The carded base is one registry programme (FRIEND) in three reports: treadmill standards (N=7,783), cycle-ergometry standards (N=4,494) and the updated combined standards (N=22,379). The pattern is concordant across all three: values are higher in men than women at every age, higher on the treadmill than the cycle, and fall with age at roughly 10% per decade in relative terms in the original reports (13.5–16.4% per decade in the updated report, printed beside the absolute falls of 4.0–4.3 mL/kg/min per decade). Registry volunteers are self-selected people referred for or volunteering for maximal exercise testing, not a random population sample — the standards describe tested, apparently healthy adults without cardiovascular disease, and the updated treadmill standards came in 1.5–4.6 mL/kg/min lower than the 2015 standards as the sample broadened.
MeSH: Adult · Age Factors · Aged · Cohort Studies · Exercise Test · Female · Humans · Male · Middle Aged · Oxygen Consumption · Physical Fitness · Reference Values · Registries · Research · Sex Factors · United States
Cards (4)
Card 1 — FRIEND treadmill standards 2015: median VO2max fell from 48.0 mL/kg/min in men and 37.6 in women aged 20–29 to 24.4 and 18.3 at ages 70–79 — about a 10% relative fall per decade
Study: Primary human physiology study
Population: 7,783 maximal treadmill cardiopulmonary exercise tests (respiratory exchange ratio ≥1.0) from men and women aged 20–79 years without cardiovascular disease, contributed by 8 US laboratories to the FRIEND registry (tests from January 2014 to February 2015).
Summary: FRIEND treadmill standards 2015: median VO2max fell from 48.0 mL/kg/min in men and 37.6 in women aged 20–29 to 24.4 and 18.3 at ages 70–79 — about a 10% relative fall per decade
Result: Percentiles of maximal oxygen consumption were determined for each decade from age 20 through 79, separately by sex. The 50th percentile fell from 48.0 (men) and 37.6 (women) mLO2·kg-1·min-1 at ages 20–29 to 24.4 (men) and 18.3 (women) at ages 70–79 — an absolute fall of 23.6 mL/kg/min in men and 19.3 in women across five decades, described by the authors as a rate of decline of approximately 10% per decade (a relative rate; the absolute decade medians are printed here beside it). FRIEND values differed from Norwegian CPX reference data and from older US standards derived from workload estimation rather than measured gas exchange.
Watch out: Registry volunteers tested in experienced laboratories — self-selected, apparently healthy adults, not a random population sample; values apply to maximal treadmill tests meeting the effort criterion, not to submaximal or estimated fitness.
Source: Primary human physiology study (registry reference-standards report) | Kaminsky LA, Arena R, Myers J. Reference Standards for Cardiorespiratory Fitness Measure With Cardiopulmonary Exercise Testing: Data From the Fitness Registry and the Importance of Exercise National Database. Mayo Clin Proc. 2015. PMID: 26455884. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Cohort Studies · Exercise Test · Female · Humans · Male · Middle Aged · Oxygen Consumption · Physical Fitness · Reference Values · Registries · Research · Sex Factors · United States
Card 2 — FRIEND cycle-ergometry standards 2017: median VO2max fell from 41.9 mL/kg/min in men and 31.0 in women aged 20–29 to 19.5 and 14.8 at ages 70–79 — cycle values run below treadmill values at every age
Study: Primary human physiology study
Population: 4,494 maximal cycle-ergometer cardiopulmonary exercise tests (respiratory exchange ratio ≥1.1) from men and women aged 20–79 years from 27 states, without cardiovascular disease, contributed by 10 US laboratories to the FRIEND registry (April 2014 to May 2016).
Summary: FRIEND cycle-ergometry standards 2017: median VO2max fell from 41.9 mL/kg/min in men and 31.0 in women aged 20–29 to 19.5 and 14.8 at ages 70–79 — cycle values run below treadmill values at every age
Result: Percentiles of maximum oxygen consumption were determined per decade and sex for cycle ergometry. The 50th percentile fell from 41.9 (men) and 31.0 (women) mLO2/kg/min at ages 20–29 to 19.5 (men) and 14.8 (women) at ages 70–79 — absolute falls of 22.4 and 16.2 mL/kg/min, a rate of decline of approximately 10% per decade (relative rate, with the absolute medians printed beside it). At the youngest decade the cycle medians sit about 6 mL/kg/min below the treadmill medians from the same registry, confirming that mode-specific standards are required: a cycle value must not be read against treadmill percentiles.
Watch out: A stricter effort criterion (respiratory exchange ratio ≥1.1) than the treadmill report (≥1.0) — cross-mode comparisons carry that protocol difference as well as the true mode difference.
Source: Primary human physiology study (registry reference-standards report) | Kaminsky LA, Imboden MT, Arena R, Myers J. Reference Standards for Cardiorespiratory Fitness Measure With Cardiopulmonary Exercise Testing Using Cycle Ergometry: Data From the Fitness Registry and the Importance of Exercise National Database (FRIEND) Registry. Mayo Clin Proc. 2017. PMID: 27938891. Registry ID: none in the record. MeSH: Adult · Aged · Body Mass Index · Cardiorespiratory Fitness · Exercise Test · Female · Humans · Male · Middle Aged · Reference Values · United States · Young Adult
Card 3 — Updated FRIEND standards 2022 (N=22,379): average decline 13.5% per decade on the treadmill (4.0 mL/kg/min) and 16.4% per decade on the cycle (4.3 mL/kg/min); updated treadmill standards sit 1.5–4.6 mL/kg/min below the 2015 standards
Study: Primary human physiology study
Population: 22,379 cardiopulmonary exercise tests (16,278 treadmill and 6,101 cycle ergometer) from apparently healthy adults aged 20–89 years, contributed by 34 US laboratories to the FRIEND registry (tests conducted 1968–2021).
Summary: Updated FRIEND standards 2022 (N=22,379): average decline 13.5% per decade on the treadmill (4.0 mL/kg/min) and 16.4% per decade on the cycle (4.3 mL/kg/min); updated treadmill standards sit 1.5–4.6 mL/kg/min below the 2015 standards
Result: Percentiles of peak oxygen consumption were determined per decade (20 through 89 years), sex and exercise mode, under both respiratory exchange ratio ≥1.0 and ≥1.1 effort criteria; mean peak values were observationally similar under either criterion. For both sexes the 50th percentile fell with age, was higher in men at every age, and was higher for treadmill than cycle testing. The average rate of decline per decade over six decades was 13.5% (relative), 4.0 mLO2·kg-1·min-1 (absolute), for treadmill testing and 16.4% (relative), 4.3 mLO2·kg-1·min-1 (absolute), for cycle testing. The updated treadmill standards were 1.5–4.6 mLO2·kg-1·min-1 lower than the 2015 standards, while the updated cycling standards were generally comparable to the 2017 standards — a reminder that reference values move as the reference sample broadens.
Watch out: Tests span 1968–2021 and 34 laboratories — equipment and protocol generations differ across the pooled sample; the standards are for apparently healthy tested adults, and percentile position is not by itself a diagnosis or a prognosis.
Source: Primary human physiology study (registry reference-standards update) | Kaminsky LA, Arena R, Myers J, Peterman JE. Updated Reference Standards for Cardiorespiratory Fitness Measure with Cardiopulmonary Exercise Testing: Data from the Fitness Registry and the Importance of Exercise National Database (FRIEND). Mayo Clin Proc. 2022. PMID: 34809986. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cardiorespiratory Fitness · Databases, Factual · Exercise Test · Female · Humans · Male · Middle Aged · Oxygen Consumption · Physical Fitness · Reference Standards · Reference Values · Registries · United States · Young Adult
Card 4 — Synthesis: peak oxygen uptake has usable age-, sex- and mode-specific percentile standards — men above women, treadmill above cycle, and a fall of roughly a tenth to a sixth of the value per decade
Study: Synthesis
Population: Synthesis of Kaminsky 2015 (treadmill, N=7,783), Kaminsky 2017 (cycle, N=4,494) and Kaminsky 2022 (updated combined, N=22,379), framed by Boron & Boulpaep Medical Physiology (textbook framing, not an evidence card).
Summary: Synthesis: peak oxygen uptake has usable age-, sex- and mode-specific percentile standards — men above women, treadmill above cycle, and a fall of roughly a tenth to a sixth of the value per decade
Result: The three FRIEND reports agree on the shape of normal cardiorespiratory fitness. At the median, a healthy man in his twenties reaches about 48 mL/kg/min on a treadmill and about 42 on a cycle; a healthy woman reaches about 38 and 31 respectively. By the seventies those medians have roughly halved (treadmill 24.4 and 18.3; cycle 19.5 and 14.8). The relative rate of decline is approximately 10% per decade in the original reports and 13.5% (treadmill) to 16.4% (cycle) per decade in the updated report, corresponding to absolute falls of about 4.0–4.3 mL/kg/min per decade — relative and absolute figures are printed together throughout this shelf, per the standing wording rule. Three practical consequences: read a result only against the standard for its own exercise mode; expect the percentile, not the raw value, to carry the age comparison; and treat the standards as describing self-selected tested volunteers, so a low percentile is a prompt for clinical context, not a stand-alone verdict. This shelf is the population-standards companion to the existing shelf on what limits maximal oxygen uptake (cardiac output versus peripheral extraction), which asks the mechanism question and is not duplicated here.
Watch out: Synthesis: all three reports come from one registry programme (FRIEND) — the standards are internally concordant but rest on a single, self-selected US testing population, not on independent population samples.
Source: Synthesis of Kaminsky LA et al. Mayo Clin Proc. 2015 (PMID: 26455884); Kaminsky LA et al. Mayo Clin Proc. 2017 (PMID: 27938891); Kaminsky LA et al. Mayo Clin Proc. 2022 (PMID: 34809986). Registry IDs: none in the records.