SourceMed · Shelf #7087 in the ask interface
Diaphragm ultrasound in health: end-expiratory thickness lower limits 1.3 mm (men) / 1.1 mm (women) seated, thickening-fraction lower limits ~39–48%, deep-breathing excursion ~5 cm supine
Shelf #7087 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2018–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what are diaphragm thickness, thickening fraction and excursion on ultrasound at rest and during deep breathing, by sex and posture — the reference values and limits of normality?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED — for thickness and thickening in healthy adults, framed by Guyton & Hall / Boron & Boulpaep on the diaphragm and respiratory mechanics as textbook framing, not as an evidence card. Two large healthy cohorts measured in different postures converge on the same muscle: seated, end-expiratory thickness has a lower limit of normality of 1.3 mm in men and 1.1 mm in women, with thickening-fraction lower limits around 39–48% by side and sex (Boussuges 2021, N = 200); supine, mean end-expiratory thickness is 0.14 ± 0.05 cm (1.4 mm) rising to 0.29 ± 0.10 cm at end-inspiration, with quiet-breathing excursion 1.68 ± 0.37 cm and deep-breathing excursion 5.06 ± 1.40 cm (Zhang 2024, N = 212). Women have thinner diaphragms than men in both cohorts, while thickening fraction does not differ by sex — the pattern is consistent across posture and centre. A smaller study (N = 64) ties the ultrasound measures to function: deep-breathing mobility, total-lung-capacity thickness and thickening fraction correlate with lung function and inspiratory strength, including inspiratory gastric pressure in a 40-person subgroup (Cardenas 2018). Posture and breathing manoeuvre move the numbers, so each card names its own; the values are not pooled across postures. Cross-point, not duplicated: the mouth-pressures shelf (MIP/MEP reference values) measures the same muscle system by pressure rather than by imaging.
MeSH: Diaphragm · Ultrasonography · Reference Values · Muscle Strength · Respiratory Function Tests
Cards (4)
Card 1 — Boussuges 2021: seated reference values in 200 healthy volunteers — end-expiratory thickness lower limit 1.3 mm (men) / 1.1 mm (women); thickening-fraction lower limits 39–48%
Study: Human ultrasound reference-values study (diaphragm, seated), Front Med 2021
Population: Two hundred healthy volunteers (100 men, 100 women) with normal pulmonary function tests, studied seated; diaphragm thickness was measured on both sides at the zone of apposition during quiet breathing at end-expiration and end-inspiration and after maximal inspiration, and the thickening ratio, thickening fraction and an end-inspiration/deep-breathing thickness ratio were derived.
Summary: Boussuges 2021: seated reference values in 200 healthy volunteers — end-expiratory thickness lower limit 1.3 mm (men) / 1.1 mm (women); thickening-fraction lower limits 39–48%
Result: Women had thinner hemidiaphragms than men on both sides at all breathing times. The lower limit of normality for end-expiratory thickness was 1.3 mm in men and 1.1 mm in women, on both sides. Thickening fraction did not differ significantly between sexes: observed ranges in men were 60–260% (left) and 57–200% (right), in women 58–264% (left) and 60–229% (right); its lower limits of normality were 40% (right) and 39% (left) in men, and 39% (right) and 48% (left) in women. The upper limit of normal for the mean-of-both-sides ratio of thickness at end-inspiration to thickness at deep breathing was 0.78 in women and 0.79 in men.
Watch out: Seated values at the zone of apposition — posture and measurement site are part of the number; do not apply these limits to supine ICU measurements without the posture difference in view.
Source: Boussuges A, Rives S, Finance J, Chaumet G, Vallée N, Risso JJ, Brégeon F. Ultrasound Assessment of Diaphragm Thickness and Thickening: Reference Values and Limits of Normality When in a Seated Position. Frontiers in medicine. 2021. PMID: 34778304. Registry ID: none in the record. MeSH: not captured from the record
Card 2 — Zhang 2024: supine multimodal values in 212 healthy subjects — thickness 0.14 ± 0.05 cm at end-expiration, 0.29 ± 0.10 cm at end-inspiration; excursion 1.68 cm quiet, 5.06 cm deep breathing
Study: Human ultrasound reference-values study (diaphragm, supine, multimodal), Int J Gen Med 2024
Population: Two hundred and twelve subjects (105 men, 107 women) with normal spirometry, studied supine with multimodal ultrasound: contraction and motion parameters plus shear-wave velocity; effects of sex, age, body mass index and lifestyle were analysed.
Summary: Zhang 2024: supine multimodal values in 212 healthy subjects — thickness 0.14 ± 0.05 cm at end-expiration, 0.29 ± 0.10 cm at end-inspiration; excursion 1.68 cm quiet, 5.06 cm deep breathing
Result: Diaphragm thickness at end-expiration was 0.14 ± 0.05 cm and at end-inspiration 0.29 ± 0.10 cm, with thickening fraction 1.11 ± 0.54 (printed as a ratio in the record). Excursion was 1.68 ± 0.37 cm with velocity 1.45 ± 0.41 cm/s during calm breathing, and 5.06 ± 1.40 cm with velocity 3.20 ± 1.18 cm/s during deep breathing. Longitudinal shear modulus averaged 16.72 ± 4.07 kPa. Male thickness exceeded female (P < 0.05) with no sex difference in thickening fraction; thickness rose weakly with age, calm-breathing excursion fell with age and body mass index, and deep-breathing excursion and velocity correlated with lifestyle.
Watch out: Supine values — excursion and thickness differ from the seated card by posture, kept separate on this shelf. Thickening fraction is printed as a ratio (1.11 ± 0.54) in this record versus percentages in the seated record; the two are the same quantity in different dress and are not averaged.
Source: Zhang T, Liu Y, Xu D, Dong R, Song Y. Diaphragm Assessment by Multimodal Ultrasound Imaging in Healthy Subjects. International journal of general medicine. 2024. PMID: 39290234. Registry ID: none in the record. MeSH: not captured from the record
Card 3 — Cardenas 2018: in 64 healthy subjects, deep-breathing ultrasound mobility, thickness and thickening fraction correlate with lung function and inspiratory strength — quiet-breathing measures do not separate the sexes, deep-breathing measures do
Study: Human ultrasound–function correlation study (diaphragm in healthy subjects), Ultrasound Med Biol 2018
Population: Sixty-four healthy subjects (30 men) with lung function and inspiratory strength (maximal inspiratory pressure and sniff nasal inspiratory pressure) measured; gastric and oesophageal pressures were measured in a subgroup of 40. Ultrasound characterised mobility in quiet and deep breathing and thickness at functional residual capacity and total lung capacity, with thickening fraction calculated.
Summary: Cardenas 2018: in 64 healthy subjects, deep-breathing ultrasound mobility, thickness and thickening fraction correlate with lung function and inspiratory strength — quiet-breathing measures do not separate the sexes, deep-breathing measures do
Result: During quiet breathing, ultrasound measures were similar between sexes; during deep breathing, women had lower mobility, thickness and thickening fraction than men. Deep-breathing mobility, thickness at total lung capacity and thickening fraction correlated significantly with lung function and inspiratory strength, and ultrasound measures correlated with inspiratory gastric pressure — the imaging tracks the muscle's pressure-generating function when the muscle is actually loaded, which is during deep breathing rather than at rest.
Watch out: Correlations are reported as significant in the record without coefficients in its abstract — this card claims the direction and significance the record states, not effect sizes it does not print. N = 64 (pressure subgroup 40).
Source: Cardenas LZ, Santana PV, Caruso P, Ribeiro de Carvalho CR, Pereira de Albuquerque AL. Diaphragmatic Ultrasound Correlates with Inspiratory Muscle Strength and Pulmonary Function in Healthy Subjects. Ultrasound in medicine & biology. 2018. PMID: 29373153. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Diaphragm/diagnostic imaging/physiology · Female · Humans · Lung/physiology · Male · Middle Aged · Muscle Strength/physiology · Reference Values · Respiratory Function Tests · Ultrasonography/methods · Young Adult
Card 4 — Synthesis: diaphragm thickness ~1.1–1.4 mm at end-expiration with thickening-fraction lower limits near 40% and deep-breathing excursion ~5 cm — thinner in women, fraction sex-independent, all posture- and manoeuvre-specific
Study: Synthesis
Population: Synthesis of the three carded human studies above (Boussuges 2021; Zhang 2024; Cardenas 2018), framed by the Guyton & Hall / Boron & Boulpaep account of diaphragmatic mechanics as textbook framing, not as an evidence card.
Summary: Synthesis: diaphragm thickness ~1.1–1.4 mm at end-expiration with thickening-fraction lower limits near 40% and deep-breathing excursion ~5 cm — thinner in women, fraction sex-independent, all posture- and manoeuvre-specific
Result: The concordant picture across 476 healthy subjects in three cohorts: a thin muscle at rest (end-expiratory thickness means/limits around 1.1–1.4 mm depending on sex and posture) that roughly doubles in thickness and shortens by about 1.7 cm in quiet breathing and about 5 cm in deep breathing; thickening fraction, with lower limits of normality near 39–48%, is the sex-independent index, while absolute thickness is not. The functional card explains why deep-breathing measures carry the signal — they correlate with inspiratory strength and gastric pressure where quiet-breathing measures do not. Posture (seated vs supine) and side are part of every number and are named on each card rather than pooled away. No refusals on this shelf: all three slated anchors verified from abstract-present records. No animal data are carded.
Watch out: Reference limits come from healthy volunteers with normal spirometry/pulmonary function; applying them to critically ill or neuromuscular populations is a clinical extrapolation the shelf does not make.
Source: Synthesis of the carded records above (PMIDs 34778304, 39290234, 29373153), with textbook framing as cited. Registry ID: none in the record. MeSH: not captured from the record