Wideband middle-ear measures: absorbance curves shift with age, sex and pressure — older ears lower at 1587–3175 Hz, negative pressure cuts absorbance near 1 kHz; norms still system-specific (EMERGING)

Shelf #7090 · Eyes, skin, nose & allergy

PHYSIOLOGY — EMERGING

Stamped: 2026-11-28.

Evidence published: 2016–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are normal wideband acoustic absorbance / tympanometry measures of middle-ear function across frequency — and how do age, sex and middle-ear pressure shift them?

Balance of the evidence

PHYSIOLOGY — EMERGING — the measurement family is established but its normative distributions are still accumulating and are device- and pressure-condition-dependent, so this shelf is graded EMERGING rather than ESTABLISHED. Textbook framing is thin — Ganong / Boron & Boulpaep cover middle-ear impedance matching in principle, named here as framing, not as an evidence card; the shelf rests chiefly on the primary measurement literature, as its slate row directs. What the primary studies show: in 95 adults with normal middle-ear function measured on an Interacoustics Titan system (226–8000 Hz), energy absorbance at tympanometric peak pressure differs by age in a frequency-specific pattern — older adults higher at 500–794 Hz and 5040–6350 Hz, lower at 1587–3175 Hz than young adults — with resonance frequency lower in older adults, and a consistent sex pattern (men higher absorbance at low frequencies, lower at high frequencies) in every age group (Kavruk 2024). Middle-ear pressure itself moves the measurement: induced negative pressure in 8 normal ears reduced power absorbance most strongly at 0.8–1.9 kHz, consistent with increased stiffness at the tympanic membrane (Robinson 2016; N = 8 on the face). Wideband reflex thresholds run lower than clinical 226 Hz thresholds in 39 normal-hearing adults, and differ between peak-pressure and ambient-pressure measurement (Schairer 2022). Because absorbance depends on the test system, the pressure condition and the frequency band, no single universal normal curve is claimed — values are carded per system and condition. Cross-point, not duplicated: the pure-tone hearing-threshold shelf measures cochlear sensitivity; this shelf measures the middle-ear mechanics in front of the cochlea.

MeSH: Acoustic Impedance Tests · Ear, Middle · Tympanic Membrane · Reflex, Acoustic · Auditory Threshold

Cards (4)

Card 1 — Kavruk 2024: wideband tympanometry in 95 normal adults — older adults show higher absorbance at 500–794 and 5040–6350 Hz and lower at 1587–3175 Hz than the young, with lower resonance frequency; men run higher at low and lower at high frequencies in every age group

Study: Human normative study (wideband tympanometry by age and sex), Ear Hear 2024

Population: Ninety-five adults with normal middle-ear function in three age groups — 32 young (16 men, 16 women, 20–39 years), 31 middle-aged (15 men, 16 women, 41–60 years) and 32 older (16 men, 16 women, 65–82 years) — measured with wideband tympanometry from 226 to 8000 Hz on an Interacoustics Titan system; energy absorbance at tympanometric peak pressure and at ambient pressure at third-octave frequencies, plus resonance frequency, were analysed by age and sex.

Summary: Kavruk 2024: wideband tympanometry in 95 normal adults — older adults show higher absorbance at 500–794 and 5040–6350 Hz and lower at 1587–3175 Hz than the young, with lower resonance frequency; men run higher at low and lower at high frequencies in every age group

Result: Mean absorbance at peak pressure was significantly higher from 500 to 794 Hz and at 5040 and 6350 Hz, and significantly lower from 1587 to 3175 Hz, in older adults compared with young adults; ambient-pressure absorbance showed the same mid-frequency lowering and high-frequency raising. No frequency differed significantly between young and middle-aged, or between middle-aged and older, adults. Resonance frequency was significantly lower in older than young adults. In all age groups men had higher mean absorbance at lower frequencies and lower at higher frequencies than women, and slightly (middle-aged: significantly) lower resonance frequency. The authors propose age- and sex-specific wideband norms rather than a single adult norm.

Watch out: Single test system (Interacoustics Titan, named as published) and significance reported by frequency band without absolute absorbance values in the record's abstract — this card reports the pattern and direction the record establishes, not invented absorbance numbers.

Source: Kavruk H, Öztürk B. Investigation of Age and Gender Effects on the Middle Ear With Wideband Tympanometry in Adults. Ear and hearing. 2024. PMID: 38017621. Registry ID: none in the record. MeSH: Middle Aged · Young Adult · Female · Humans · Male · Aged · Acoustic Impedance Tests/methods · Ear, Middle · Sound · Ear Canal · Vibration

Card 2 — Robinson 2016: induced negative middle-ear pressure in 8 normal ears cuts wideband power absorbance most at 0.8–1.9 kHz (small rise above ~4 kHz) — a stiffness increase at the tympanic membrane; N = 8

Study: Human experimental physiology study (wideband immittance under negative middle-ear pressure), Ear Hear 2016

Population: Eight subjects with normal middle-ear function, trained to induce consistent negative middle-ear pressures, quantified by tympanometric peak pressure and wideband acoustic immittance; measurements in negative-pressure and ambient-pressure conditions were analysed per ear, with the residual ear-canal delay removed to estimate complex immittance at the tympanic membrane and a classical middle-ear model fitted. N = 8 printed on the face.

Summary: Robinson 2016: induced negative middle-ear pressure in 8 normal ears cuts wideband power absorbance most at 0.8–1.9 kHz (small rise above ~4 kHz) — a stiffness increase at the tympanic membrane; N = 8

Result: Negative middle-ear pressure had its largest and most consistent effect from 0.8 to 1.9 kHz, reducing power absorbance by the middle ear and cochlea; on average absorbance fell at low-to-mid frequencies with a small increase above about 4 kHz, but effects varied considerably across ears. At the tympanic membrane, negative pressure decreased aggregate compliance — consistent with increased stiffness of the membrane, tensor tympani, annular ligament or other middle-ear structures — while estimated ear-canal delays barely changed. Tympanometric peak pressure was not a strong predictor of the change at the membrane, given baseline between-ear variability.

Watch out: N = 8, printed on the face — a classic small mechanistic study; pressures were self-induced by trained subjects, so magnitudes are a laboratory model of negative pressure, not a clinical Eustachian-dysfunction distribution.

Source: Robinson SR, Thompson S, Allen JB. Effects of Negative Middle Ear Pressure on Wideband Acoustic Immittance in Normal-Hearing Adults. Ear and hearing. 2016. PMID: 26871877. Registry ID: none in the record. MeSH: Acoustic Impedance Tests · Adult · Ear, Middle · Hearing · Hearing Tests · Humans · Pressure · Tympanic Membrane

Card 3 — Schairer 2022: wideband acoustic reflex thresholds in 39 normal-hearing adults are significantly lower than clinical 226 Hz thresholds — and higher at tympanometric peak pressure than at ambient pressure (500/2000 Hz ipsilateral)

Study: Human normative/methods study (wideband acoustic reflex thresholds), Ear Hear 2022

Population: Thirty-nine adults with normal hearing (21 men; mean age 47.7 years, range 23–72), both ears tested prospectively; acoustic reflex thresholds were obtained ipsilaterally and contralaterally with 500, 1000 and 2000 Hz and broadband-noise activators on a clinical system (manual method) and on an experimental wideband system with automated adaptive threshold detection, the wideband thresholds estimated at both tympanometric peak pressure and ambient pressure. Broadband activator bandwidth was 125–4000 Hz (clinical) versus 200–8000 Hz (wideband).

Summary: Schairer 2022: wideband acoustic reflex thresholds in 39 normal-hearing adults are significantly lower than clinical 226 Hz thresholds — and higher at tympanometric peak pressure than at ambient pressure (500/2000 Hz ipsilateral)

Result: Wideband reflex thresholds at both peak pressure and ambient pressure were significantly lower than clinical-system thresholds — reflex-related absorbance change is detectable across multiple frequency bands where the single-frequency clinical probe sees less. Wideband thresholds at peak pressure were significantly higher than at ambient pressure in the 500 and 2000 Hz ipsilateral conditions. The authors note the lower wideband levels may be more tolerable and may reveal reflexes absent at a traditional test's maximum level, and that automation suits telehealth workflows.

Watch out: Threshold differences are reported as significant in the record without decibel magnitudes in its abstract — this card claims the direction and significance, not a dB gap. The wideband system was an experimental system, named as such; clinical-system equivalence is not assumed.

Source: Schairer KS, Putterman DB, Keefe DH, Fitzpatrick D, Garinis A, Kolberg E, Feeney MP. Automated Adaptive Wideband Acoustic Reflex Threshold Estimation in Normal-hearing Adults. Ear and hearing. 2022. PMID: 34320528. Registry ID: none in the record. MeSH: Acoustic Impedance Tests/methods · Adult · Aged · Auditory Threshold · Ear, Middle · Female · Hearing · Humans · Male · Middle Aged · Prospective Studies · Reflex, Acoustic · Young Adult

Card 4 — Synthesis: wideband absorbance is age-, sex-, frequency- and pressure-dependent — no single normal curve exists yet; negative pressure stiffens the system near 1 kHz and wideband reflex thresholds run below clinical thresholds

Study: Synthesis

Population: Synthesis of the three carded human studies above (Kavruk 2024; Robinson 2016; Schairer 2022), with the Ganong / Boron & Boulpaep account of middle-ear impedance matching named as thin textbook framing, not as an evidence card — this shelf rests chiefly on the primary measurement literature.

Summary: Synthesis: wideband absorbance is age-, sex-, frequency- and pressure-dependent — no single normal curve exists yet; negative pressure stiffens the system near 1 kHz and wideband reflex thresholds run below clinical thresholds

Result: The consistent physiology across three different wideband designs: middle-ear sound transmission, measured as energy absorbance across 226–8000 Hz, is not a single number — it is a frequency curve that shifts with age (mid-frequency absorbance lower, low- and high-frequency higher, resonance frequency lower in older adults), differs by sex at every age, and moves with middle-ear pressure, negative pressure reducing absorbance most near 0.8–1.9 kHz via increased stiffness at the membrane. Wideband reflex thresholds sit below traditional 226 Hz clinical thresholds and depend on the pressure condition of measurement. Because systems (a named commercial Titan; an experimental wideband rig) and conditions differ between studies, the shelf grades the topic EMERGING and cards each value-set under its own system and condition rather than merging them into universal norms. No refusals on this shelf: all three slated anchors verified from abstract-present records. No animal data are carded.

Watch out: Absorbance values are system- and calibration-specific; cross-system numerical comparison requires the harmonisation work this literature has not yet produced — the reason for the EMERGING grade.

Source: Synthesis of the carded records above (PMIDs 38017621, 26871877, 34320528), with textbook framing as cited. Registry ID: none in the record. MeSH: not captured from the record