SourceMed · Shelf #710 in the ask interface
Subcutaneous vs transvenous ICD: trading lead complications for shocks?
Shelf #710 · Heart, vessels, blood pressure & clotting
LIKELY (the trade-off, not a winner)
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2020–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients who need a defibrillator but not pacing, does a fully subcutaneous ICD match a transvenous ICD on complications and inappropriate shocks (PRAETORIAN, ATLAS)?
Balance of the evidence
LIKELY (the trade-off, not a winner): Two randomised trials and their individual-patient-data pooling agree on the shape of the exchange. The subcutaneous ICD avoids the vein and the lead: perioperative lead-related complications were 0.4% vs 4.8% in ATLAS, and device-related complications ran lower in PRAETORIAN (hazard ratio 0.69). In return it shocks inappropriately more often — the pooled first-inappropriate-shock rate was 2.5 vs 1.5 per 100 patient-years (hazard ratio 1.61, a relative figure inside the 0.5–2.0 band this library treats as not solid on its own, though here it is pooled randomised data, not an observational claim). PRAETORIAN's composite of complications plus inappropriate shocks was noninferior (hazard ratio 0.99). Who benefits from a prophylactic ICD at all is Shelf #90; this shelf is only about which box, once one is chosen.
MeSH: Arrhythmias, Cardiac/therapy · Cardiomyopathies/therapy · Death, Sudden, Cardiac/epidemiology,prevention & control · Defibrillators, Implantable/adverse effects · Electrodes, Implanted/adverse effects · Equipment Failure · Heart Diseases/therapy
Cards (4)
Card 1 — PRAETORIAN 2020: subcutaneous ICD was noninferior to transvenous ICD on complications plus inappropriate shocks — hazard ratio 0.99
Study: Randomised noninferiority trial
Population: 849 patients with an indication for an ICD but no indication for pacing, randomised to subcutaneous ICD (426) or transvenous ICD (423); median follow-up 49.1 months. The abstract does not state mean age.
Summary: PRAETORIAN 2020: subcutaneous ICD was noninferior to transvenous ICD on complications plus inappropriate shocks — hazard ratio 0.99.
Result: A primary end-point event (device-related complications or inappropriate shocks) occurred in 68 patients in each group (48-month Kaplan–Meier cumulative incidence 15.1% vs 15.7%; hazard ratio 0.99, 95% CI 0.71 to 1.39; P=0.01 for noninferiority, P=0.95 for superiority). Device-related complications occurred in 31 vs 44 patients (hazard ratio 0.69, 0.44 to 1.09) and inappropriate shocks in 41 vs 29 (hazard ratio 1.43, 0.89 to 2.30). Death occurred in 83 vs 68 patients (hazard ratio 1.23, 0.89 to 1.70) and appropriate shocks in 83 vs 57 (hazard ratio 1.52, 1.08 to 2.12) — secondary figures, printed because this shelf's trade-off cannot be read without them.
Watch out: Noninferiority on a composite that mixes the two opposing harms can hide the trade-off inside it; the component figures above are the shelf's real content. Device trials cannot be blinded.
Source: Knops RE et al. Subcutaneous or Transvenous Defibrillator Therapy. N Engl J Med. 2020;383(6):526-536. PMID: 32757521. Registry ID: ClinicalTrials.gov NCT01296022, from the record's databank fields.
Card 2 — ATLAS 2022: lead-related perioperative complications 0.4% with subcutaneous vs 4.8% with transvenous ICD
Study: Randomised, multicentre trial
Population: 544 eligible patients with a primary or secondary prevention ICD indication who were younger than 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications; 503 randomised to subcutaneous ICD (251) or transvenous ICD (252); mean age 49.0 years (SD 11.5); 141 of the 544 eligible patients were female; mean follow-up 2.5 years (SD 1.1).
Summary: ATLAS 2022: lead-related perioperative complications 0.4% with subcutaneous vs 4.8% with transvenous ICD.
Result: Perioperative major lead-related complications occurred in 1 patient (0.4%) with a subcutaneous ICD and 12 patients (4.8%) with a transvenous ICD (difference −4.4 percentage points, 95% CI −6.9 to −1.9; P=0.001). There was a trend to more inappropriate shocks with the subcutaneous device (hazard ratio 2.37, 0.98 to 5.77 — a relative figure) and no increase in failed appropriate shocks (hazard ratio 0.61, 0.15 to 2.57). Implant-site pain was higher with the subcutaneous device on the day of implant (4.2 vs 2.9 on a 10-point scale; P<0.001) and at 1 month (1.3 vs 0.9; P=0.035).
Watch out: A younger, lead-risk-enriched population (mean age 49) — the lead-complication advantage may be smaller in older, lower-risk recipients; the trial states it is as yet underpowered for clinical shock outcomes, with extended follow-up ongoing.
Source: Healey JS et al. Perioperative Safety and Early Patient and Device Outcomes Among Subcutaneous Versus Transvenous Implantable Cardioverter Defibrillator Implantations: A Randomized, Multicenter Trial. Ann Intern Med. 2022;175(12):1658-1665. PMID: 36343346. Registry ID: ClinicalTrials.gov NCT02881255, from the record's databank fields.
Card 3 — IPD meta-analysis 2026: first inappropriate shock was more frequent with subcutaneous ICDs — 2.5 vs 1.5 per 100 patient-years
Study: Individual participant data meta-analysis of randomised trials
Population: Pooled modified intention-to-treat population of PRAETORIAN and ATLAS: 1,342 patients randomised to subcutaneous or transvenous ICD; median age 58 years, 21.8% women, 77.7% primary-prevention indications; median follow-up 3.5 years.
Summary: IPD meta-analysis 2026: first inappropriate shock was more frequent with subcutaneous ICDs — 2.5 vs 1.5 per 100 patient-years.
Result: A first inappropriate shock occurred more frequently with subcutaneous ICDs (2.5 vs 1.5 per 100 patient-years; hazard ratio 1.61, 95% CI 1.06 to 2.45; P=0.03 — a relative figure). By cause, subcutaneous devices had a higher hazard of inappropriate shock from cardiac oversensing (hazard ratio 15.07, 3.60 to 63.15) and electromagnetic interference or myopotentials (hazard ratio 8.19, 1.88 to 35.64), but a lower hazard from atrial arrhythmia (hazard ratio 0.37, 0.19 to 0.71). A proprietary inappropriate-shock-reduction algorithm was activated at some point in 77.1% of subcutaneous recipients.
Watch out: This is a pooling of the same two trials carded above — counted once as evidence, as a synthesis of them, never as a third trial. The hazard ratio of 1.61 sits inside the 0.5–2.0 caution band; it is believed here because it pools randomised data, not on its size alone.
Source: Benz AP et al. Inappropriate Shocks From Subcutaneous vs Transvenous Implantable Cardioverter-Defibrillators: Individual Participant Data Meta-Analysis of Randomized Trials. J Am Coll Cardiol. 2026;87(14):1732-1743. PMID: 41369620. Registry ID: none in the record's databank fields — this is a meta-analysis of two registered trials (NCT01296022, NCT02881255).
Card 4 — Synthesis: fewer lead complications, more inappropriate shocks — the choice is which harm a patient can least afford — LIKELY
Study: Synthesis
Population: Synthesis of the cards above: PRAETORIAN (849 patients), ATLAS (503 randomised) and their individual-patient-data pooling (1,342 patients).
Summary: Fewer lead complications, more inappropriate shocks — LIKELY, for rhythm outcomes; no mortality claim is made.
Result: No trial shows one device better overall: PRAETORIAN's composite was a dead heat (68 events in each arm), ATLAS shows the lead-complication gap at its widest in young, lead-risk patients (0.4% vs 4.8%), and the pooling shows the inappropriate-shock gap (2.5 vs 1.5 per 100 patient-years). A patient with decades of lead life ahead, difficult venous access or infection risk buys the subcutaneous trade gladly; a patient in whom an inappropriate shock would be especially harmful, or who may later need pacing or resynchronisation the subcutaneous box cannot give, may not. Mortality itself was not the question here — the prophylactic-ICD mortality evidence is Shelf #90 and is not re-carded.
Watch out: Do not quote the pooled oversensing hazard ratio (15.07) without its absolute base: first inappropriate shocks of any kind were uncommon in both arms (≤2.5 per 100 patient-years).
Source: Synthesis of Knops RE et al. N Engl J Med. 2020;383(6):526-536. PMID: 32757521; Healey JS et al. Ann Intern Med. 2022;175(12):1658-1665. PMID: 36343346; Benz AP et al. J Am Coll Cardiol. 2026;87(14):1732-1743. PMID: 41369620. Registry IDs as on the individual cards.