SourceMed · Shelf #7151 in the ask interface

Static lung volumes: GLI-2021 equations from 7,190 Europeans aged 5–80 — plethysmography reads higher than dilution in the elderly, and borrowed middle-aged equations misclassify up to 62.5% of healthy older women as below the TLC lower limit

Shelf #7151 · Lungs, breathing & sleep

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 2009–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, what are normal static lung volumes — total lung capacity, functional residual capacity, residual volume and RV/TLC — by body plethysmography and gas dilution, per the Global Lung Function Initiative 2021 reference values?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED. Framing follows Boron & Boulpaep's lung-volumes account and Guyton & Hall ch. 37, named as textbook framing. The GLI-2021 technical standard (Hall 2021) derived sex-specific equations for TLC, FRC, RV, inspiratory capacity, vital capacity, expiratory reserve volume and RV/TLC from 7,190 observations in people of European ancestry aged 5–80, combining plethysmography and dilution FRC after finding physiologically insignificant differences between techniques in the pooled data. The independent cohorts qualify that pooling: in 321 healthy never-smokers aged 65–85 (Garcia-Rio 2009), plethysmography gave higher values than helium dilution for all volumes with wide limits of agreement, and extrapolated middle-aged equations branded 17.9–62.5% of healthy women and 12.5–42.2% of healthy men as below the TLC lower limit of normal. In 5,371 healthy Austrians (Mraz 2024), the GLI equations themselves fit poorly (mean z-scores above +0.5 for RV, RV/TLC and TLC in both sexes), prompting population-derived equations. Method and population both move the 'normal' line — values are carded per-method and per-population.

MeSH: Adolescent · Adult · Aged · Child · Female · Humans · Lung Volume Measurements · Male · Middle Aged · Reference Values · Total Lung Capacity · Vital Capacity

Cards (4)

Card 1 — Hall 2021 (GLI-2021): static lung volume equations from 7,190 observations, ages 5–80, European ancestry — plethysmographic and dilution FRC combined after showing physiologically insignificant differences

Study: Human normative programme (ERS technical standard, pooled reference equations), Eur Respir J 2021

Population: 7,190 observations from healthy participants of European ancestry aged 5–80 years, collated from 17 centres, measured by body plethysmography and gas dilution; data from non-European ancestry populations were insufficient to derive multi-ethnic equations.

Summary: Hall 2021 (GLI-2021): static lung volume equations from 7,190 observations, ages 5–80, European ancestry — plethysmographic and dilution FRC combined after showing physiologically insignificant differences

Result: Sex-specific LMS reference equations including height and age were derived for total lung capacity, functional residual capacity, residual volume, inspiratory capacity, vital capacity, expiratory reserve volume and RV/TLC. FRC measured by plethysmography and by dilution showed physiologically insignificant differences and the techniques were combined. The derived equations were similar to previously published equations for FRC and TLC, agreeing more closely in childhood and adolescence than in adulthood; overweight and obesity effects on the ranges were assessed.

Watch out: European ancestry only — the multi-ethnic aim was not met because non-European data were insufficient; and the technique-pooling decision is a pooled-data average that the elderly cohort card below shows does not hold at older ages.

Source: Hall GL et al. Official ERS technical standard: Global Lung Function Initiative reference values for static lung volumes in individuals of European ancestry. Eur Respir J. 2021. PMID: 33707167. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Child, Preschool · Female · Humans · Lung · Lung Volume Measurements · Male · Middle Aged · Reference Values · Total Lung Capacity · Vital Capacity · Young Adult

Card 2 — Garcia-Rio 2009: in 321 healthy never-smokers aged 65–85, plethysmography exceeded helium dilution for every volume, and middle-aged equations put up to 62.5% of healthy women below the TLC lower limit

Study: Human normative cohort (independent plethysmography and dilution cohort), Am J Respir Crit Care Med 2009

Population: 321 healthy never-smoker subjects aged 65–85 years, randomly selected from the general population; spirometry and lung volumes measured by both body plethysmography and multibreath helium equilibration following ATS/ERS recommendations.

Summary: Garcia-Rio 2009: in 321 healthy never-smokers aged 65–85, plethysmography exceeded helium dilution for every volume, and middle-aged equations put up to 62.5% of healthy women below the TLC lower limit

Result: Reference values with lower and upper limits of normal were derived by a piecewise polynomial model, confirming age- and body-size dependence of lung volumes in older subjects beyond height. Plethysmography provided higher values than the dilution method for all lung volumes, with wide limits of agreement. Practically all equations extrapolated from middle-aged adults overpredicted the true volumes: middle-aged reference equations classified between 17.9% and 62.5% of the women and between 12.5% and 42.2% of the men in this healthy sample as below the total lung capacity lower limit of normal.

Watch out: The misclassification percentages are ranges across several published middle-aged equation sets, not one equation's error rate; the cohort is European elderly only, and the plethysmography–dilution gap widens exactly where airway disease also widens it, so method must be recorded with every clinical volume.

Source: Garcia-Rio F et al. Lung volume reference values for women and men 65 to 85 years of age. Am J Respir Crit Care Med. 2009. PMID: 19745204. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cohort Studies · Female · Geriatric Assessment/methods, statistics & numerical data · Humans · Lung Volume Measurements/methods · Male · Plethysmography/methods, statistics & numerical data · Reference Values · Spain · Spirometry/methods, statistics & numerical data · Total Lung Capacity/physiology

Card 3 — Mraz 2024 (LEAD, Austria): in 5,371 healthy people aged 6–80, GLI static-volume equations fit poorly — mean z-scores above +0.5 for RV, RV/TLC and TLC in both sexes — so population-derived equations were built

Study: Human normative cohort (population validation and re-derivation), Respir Res 2024

Population: 5,371 respiratory-healthy subjects aged 6–80 years from the Austrian LEAD study, with spirometry and body plethysmography; fit to the GLI equations was judged by z-scores and distribution within the limits of normality, and LEAD reference equations were then created by the same LMS/GAMLSS approach.

Summary: Mraz 2024 (LEAD, Austria): in 5,371 healthy people aged 6–80, GLI static-volume equations fit poorly — mean z-scores above +0.5 for RV, RV/TLC and TLC in both sexes — so population-derived equations were built

Result: Good fit (mean z-scores between −0.5 and +0.5) was not observed for the GLI static lung volume equations: mean z-scores exceeded +0.5 for residual volume, RV/TLC and total lung capacity in both sexes, and for expiratory reserve volume and inspiratory capacity in females, with distributions shifted toward the upper limit. The population-derived LEAD equations showed superior fit and reproducible results in this cohort.

Watch out: A single-country validation: poor fit in Austria does not prove poor fit everywhere, but it is direct evidence that the GLI-2021 line is population-sensitive — the opposite of a universal constant — and the female misfit was the largest.

Source: Mraz T et al. Updated reference values for static lung volumes from a healthy population in Austria. Respir Res. 2024. PMID: 38570835. Registry ID: none in the record. MeSH: Male · Adult · Child · Female · Humans · Lung · Austria/epidemiology · Reference Values · Lung Volume Measurements/methods · Total Lung Capacity · Spirometry/methods · Forced Expiratory Volume · Vital Capacity

Card 4 — Synthesis: GLI-2021 is the shared standard for ages 5–80, but technique (plethysmography vs dilution) and population each move the normal line enough to mislabel healthy people

Study: Synthesis

Population: Synthesis of the three carded human reports above (Hall 2021; Garcia-Rio 2009; Mraz 2024), framed by Boron & Boulpaep and Guyton & Hall ch. 37 as textbook framing.

Summary: Synthesis: GLI-2021 is the shared standard for ages 5–80, but technique (plethysmography vs dilution) and population each move the normal line enough to mislabel healthy people

Result: The GLI-2021 equations (Hall) give one continuous, sex-specific standard for TLC, FRC, RV and RV/TLC across ages 5–80 in European-ancestry populations, pooling plethysmography and dilution FRC on pooled-data equivalence. The independent cohorts bound that standard from both sides: at older ages the two techniques diverge systematically (Garcia-Rio — plethysmography higher for every volume, wide limits of agreement) and borrowed middle-aged equations misclassify large fractions of healthy elderly as restrictive; and in a large unselected healthy population the GLI line itself sat high for RV, RV/TLC and TLC (Mraz), requiring local re-derivation. Read together: a static volume is only interpretable with its method and its equation set attached — the same discipline as spirometry on the neighbouring shelf.

Watch out: GLI-2021 covers European ancestry only; no carded record here supports applying these limits to other ancestry groups, and obstructed lungs widen the plethysmography–dilution gap beyond anything in these healthy cohorts.

Source: Synthesis of Hall GL et al., Eur Respir J 2021 (PMID: 33707167); Garcia-Rio F et al., Am J Respir Crit Care Med 2009 (PMID: 19745204); Mraz T et al., Respir Res 2024 (PMID: 38570835). Registry IDs as on the individual cards.