SourceMed · Shelf #7155 in the ask interface
SNIP norms: healthy adults sniff harder than they can suck — mean 76.8 cm H₂O in Japanese men and 60.0 in women (lower limits 32.9 and 28.8), children aged 6–17 already reach adult-range values, and SNIP complements rather than replaces mouth pressure
Shelf #7155 · Lungs, breathing & sleep
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1995–2009.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what is sniff nasal inspiratory pressure (SNIP) — its mean and lower limit of normal by age and sex — and how does it compare with maximal inspiratory mouth pressure as a measure of inspiratory muscle strength?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED. Framing follows Guyton & Hall ch. 37 and Boron & Boulpaep's mechanics of breathing, named as textbook framing. This shelf is the nose-measured manoeuvre only; mouth-pressure (MIP/MEP) reference values are a neighbouring question (Slate 8's S8-4-27) and are not duplicated here. Three cohorts from three age bands agree: in 160 healthy adults aged 20–80 (Uldry & Fitting 1995), maximal SNIP fell with age, was the same sitting and supine, and equalled or exceeded maximal inspiratory mouth pressure in 107 of 160 subjects (mean SNIP/PImax ratio 1.08 in men, 1.17 in women) — with agreement low enough that the authors call the two tests complementary, not interchangeable. In 223 healthy Japanese adults (Kamide 2009), mean SNIP was 76.8 ± 28.9 cm H₂O in men and 60.0 ± 20.0 in women, with lower limits of normal of 32.9 and 28.8 cm H₂O. In 180 healthy children aged 6–17 (Stefanutti & Fitting 1999), SNIP was already 104 ± 26 cm H₂O in boys and 93 ± 23 in girls — adult-range values, higher than mouth pressure at the same lung volume.
MeSH: Adolescent · Adult · Age Factors · Aged · Female · Humans · Inhalation/physiology · Male · Middle Aged · Pressure · Reference Values · Respiratory Muscles/physiology · Sex Factors
Cards (4)
Card 1 — Uldry & Fitting 1995: in 160 healthy adults aged 20–80, maximal SNIP fell with age, matched sitting and supine, and equalled or beat PImax in 107 of 160 — mean ratio 1.08 (men) and 1.17 (women)
Study: Human normative cohort (classic primary dataset, adults), Thorax 1995
Population: 160 healthy subjects (80 men) aged 20–80 years with FVC above 80%, FEV1/FVC above 85% of predicted and BMI 18–31; SNIP measured from functional residual capacity through a catheter plugging one nostril during 10 maximal sniffs, sitting and supine, and PImax measured from FRC with a flanged mouthpiece over four manoeuvres.
Summary: Uldry & Fitting 1995: in 160 healthy adults aged 20–80, maximal SNIP fell with age, matched sitting and supine, and equalled or beat PImax in 107 of 160 — mean ratio 1.08 (men) and 1.17 (women)
Result: For both men and women, maximal SNIP was negatively correlated with age and was similar in the sitting and supine positions. In the sitting position, maximal SNIP was greater than or equal to PImax in 107 of 160 subjects; the mean (SD) SNIP/PImax ratio was 1.08 (0.22) in men and 1.17 (0.29) in women. Normal SNIP values can be predicted from age and sex — but the low level of agreement between SNIP and PImax means the two manoeuvres are not interchangeable, only complementary.
Watch out: The record's abstract does not print the absolute mean SNIP values by decade, so none is claimed from this card — its carded content is the age relation, the posture equivalence and the SNIP–PImax comparison; absolute means come from the Japanese and paediatric cards.
Source: Uldry C, Fitting JW. Maximal values of sniff nasal inspiratory pressure in healthy subjects. Thorax. 1995. PMID: 7785009. Registry ID: none in the record (pre-registration era). MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Female · Humans · Inhalation/physiology · Male · Middle Aged · Posture · Pressure · Reference Values · Respiratory Mechanics/physiology · Respiratory Muscles/physiology · Sex Factors
Card 2 — Kamide 2009: in 223 healthy Japanese adults, mean SNIP was 76.8 ± 28.9 cm H₂O in men and 60.0 ± 20.0 in women, with lower limits of normal of 32.9 and 28.8 cm H₂O
Study: Human normative cohort (primary population dataset with lower limits), Respiration 2009
Population: 223 healthy Japanese volunteers (112 men, 111 women) aged 18–69 years with no history of pulmonary, heart, neuromuscular or sinus disease; SNIP measured with a nasal plug in one nostril, mouth closed, as short sharp maximal sniffs from functional residual volume, with good reproducibility by intraclass correlation in both sexes.
Summary: Kamide 2009: in 223 healthy Japanese adults, mean SNIP was 76.8 ± 28.9 cm H₂O in men and 60.0 ± 20.0 in women, with lower limits of normal of 32.9 and 28.8 cm H₂O
Result: Mean SNIP was 76.8 ± 28.9 cm H₂O in men and 60.0 ± 20.0 cm H₂O in women — significantly higher in men (P < 0.01). On stepwise multiple regression, SNIP was negatively related to age in men and positively related to body mass index in women. The lower limits of normal were 32.9 cm H₂O in men and 28.8 cm H₂O in women — roughly 40–45% of the sex-specific means (relative comparison), which is how wide the healthy spread is.
Watch out: The study exists because ethnic differences were expected — these are Japanese-population values and the authors' premise is that they should not be assumed to transfer unchanged to other populations; standard deviations near ±29 cm H₂O make any single cut-off a blunt instrument.
Source: Kamide N et al. Sniff nasal inspiratory pressure in healthy Japanese subjects: mean values and lower limits of normal. Respiration. 2009. PMID: 18957838. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Asian People · Body Mass Index · Female · Humans · Inhalation · Japan · Linear Models · Male · Middle Aged · Muscle Strength · Pressure · Reference Values · Reproducibility of Results · Young Adult
Card 3 — Stefanutti & Fitting 1999: in 180 healthy children aged 6–17, SNIP was 104 ± 26 cm H₂O in boys and 93 ± 23 in girls — adult-range values, and higher than PImax at the same lung volume in most children
Study: Human normative cohort (primary population dataset, children), Am J Respir Crit Care Med 1999
Population: 180 unselected healthy children aged 6–17 years studied in a school setting, all with FVC above 80% of predicted and FEV1/FVC above 85% of predicted; SNIP measured sitting, via a catheter occluding one nostril during maximal sniffs from FRC, with PImax measured from FRC and residual volume and PEmax from FRC and total lung capacity.
Summary: Stefanutti & Fitting 1999: in 180 healthy children aged 6–17, SNIP was 104 ± 26 cm H₂O in boys and 93 ± 23 in girls — adult-range values, and higher than PImax at the same lung volume in most children
Result: All children could perform the sniff manoeuvre easily. SNIP was 104 ± 26 cm H₂O in boys and 93 ± 23 cm H₂O in girls (P < 0.005) — values similar to those previously measured in healthy adults. SNIP correlated with age, weight and height in boys but not in girls, and in both sexes SNIP exceeded PImax measured at the same lung volume (FRC) (P < 0.0001), equalling or exceeding it in 73 of 93 boys and 79 of 87 girls.
Watch out: Children's means exceeding the Japanese adult means on the neighbouring card is a cross-population, cross-laboratory comparison (Caucasian schoolchildren vs Japanese adults, same senior author's laboratory tradition) — it shows children are not simply small adults on this test, not that one population is stronger.
Source: Stefanutti D, Fitting JW. Sniff nasal inspiratory pressure. Reference values in Caucasian children. Am J Respir Crit Care Med. 1999. PMID: 9872826. Registry ID: none in the record. MeSH: Adolescent · Aging/physiology · Body Height/physiology · Body Weight/physiology · Child · Female · Humans · Male · Methods · Nasal Cavity/physiology · Pressure · Reference Values · Respiration · Respiratory Muscles/physiology · Sex Characteristics · White People
Card 4 — Synthesis: SNIP is an easy, posture-independent sniff that usually exceeds mouth pressure — with age- and sex-structured norms, wide healthy spread, and lower limits near 30 cm H₂O in adults
Study: Synthesis
Population: Synthesis of the three carded human cohorts above (Uldry & Fitting 1995; Kamide 2009; Stefanutti & Fitting 1999), framed by Guyton & Hall ch. 37 and Boron & Boulpaep as textbook framing.
Summary: Synthesis: SNIP is an easy, posture-independent sniff that usually exceeds mouth pressure — with age- and sex-structured norms, wide healthy spread, and lower limits near 30 cm H₂O in adults
Result: One manoeuvre, three age bands, consistent findings. Performance: every child studied could do it (Stefanutti), it needs no mouthpiece seal, and posture does not change it (Uldry — sitting equals supine, unlike mouth pressure). Magnitude: healthy values centre near 77 cm H₂O in adult men and 60 in adult women with lower limits of normal at 32.9 and 28.8 (Kamide), and children aged 6–17 already average 93–104 (Stefanutti). Relation to mouth pressure: SNIP usually exceeds PImax (ratios 1.08–1.17 in adults; higher at FRC in most children) yet agrees with it too loosely to substitute for it (Uldry) — the two tests are complementary windows on inspiratory muscle strength, and a low value on either deserves the other test before it is believed.
Watch out: Norms are population-specific by the Japanese authors' own premise, and the healthy standard deviations are so wide that SNIP discriminates weakness at the low tail (near the ~30 cm H₂O lower limits) far better than it grades strength in the middle of the range.
Source: Synthesis of Uldry C, Fitting JW, Thorax 1995 (PMID: 7785009); Kamide N et al., Respiration 2009 (PMID: 18957838); Stefanutti D, Fitting JW, Am J Respir Crit Care Med 1999 (PMID: 9872826). Registry IDs as on the individual cards.