SourceMed · Shelf #7156 in the ask interface
Cough flows rest on a thin base: three small healthy-volunteer studies (N = 52, 30 and 40) — peak cough flow agrees between pneumotachograph and portable meter above 270 L/min, the meter over-reads below it, and no GLI-style normative programme exists
Shelf #7156 · Lungs, breathing & sleep
PHYSIOLOGY — EMERGING
Stamped: 2026-11-28.
Evidence published: 2004–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, what are voluntary cough flows and cough aerodynamics — peak cough flow by sex and age, glottic compression-phase behaviour and expulsive-phase flow — and how reproducible is peak cough flow measurement between pneumotachograph and portable peak-flow meter?
Balance of the evidence
PHYSIOLOGY — EMERGING — stamped emerging, not established, because the base is genuinely thin and this shelf says so on its face: there is NO GLI-style normative programme for cough flow. Framing follows Guyton & Hall ch. 37 (the cough reflex and airway mechanics) and Boron & Boulpaep's respiratory mechanics, named as textbook framing. The entire healthy-human distribution is assembled from three small volunteer studies, their Ns printed here and on every card: cough aerodynamics in 52 healthy adults (Feinstein 2017 — peak airflow rose with height, peak pressure was greater in men, expiratory rise time was longer in women); a device-agreement study with 30 healthy subjects alongside 32 neuromuscular patients (Sancho 2004 — pneumotachograph and portable meter agreed closely overall, r = 0.95, but the meter overestimated flows below 270 L/min); and airflow features of cough versus throat clearing in 40 healthy participants (Mootassim-Billah 2025 — throat clearing is aerodynamically a weaker manoeuvre than cough, P < 0.001). The widely used clinical peak-cough-flow thresholds in neuromuscular care rest on this thin base — that thinness is the teaching content of this shelf, and nothing here inflates it.
MeSH: Adult · Age Factors · Cough/diagnosis · Female · Humans · Male · Middle Aged · Peak Expiratory Flow Rate/physiology · Reference Values · Respiratory Function Tests/methods · Sex Factors
Cards (4)
Card 1 — Feinstein 2017: cough aerodynamics in 52 healthy adults (N = 52) — peak airflow rose with height, peak pressure was greater in men and rose with height, expiratory rise time was longer in women
Study: Human physiological study (healthy-volunteer cough aerodynamics, N = 52), Ann Otol Rhinol Laryngol 2017
Population: 52 healthy subjects (29 women, 23 men; mean age 51.6 years in women and 52.3 in men) recruited from an outpatient clinic, performing maximal voluntary cough with measurements recorded on a pneumotachograph; outcomes were cough peak airflow, peak pressure and expiratory rise time, stratified by age, gender and height. N = 52 — a small healthy-volunteer study, printed plainly.
Summary: Feinstein 2017: cough aerodynamics in 52 healthy adults (N = 52) — peak airflow rose with height, peak pressure was greater in men and rose with height, expiratory rise time was longer in women
Result: Peak airflow differed significantly across age, gender and height, increasing with increasing height. Peak cough pressure also increased with height and was significantly greater in males than females. Expiratory rise time — the time from glottal opening to peak airflow, the measurable signature of the compression-to-expulsive phase transition — did not vary with age or height but was statistically significantly longer in women. The authors present these as normative reference data for future studies of laryngotracheal disorders; the record's abstract does not print the absolute flow values, so none is claimed here.
Watch out: N = 52 from a single outpatient clinic, and the stratification findings are directional (the abstract reports significance, not the stratum values) — this card establishes which variables a cough-flow norm must condition on, not the conditioned values themselves.
Source: Feinstein AJ et al. Measurement of Cough Aerodynamics in Healthy Adults. Ann Otol Rhinol Laryngol. 2017. PMID: 28397558. Registry ID: none in the record. MeSH: Adult · Age Factors · Cough/diagnosis · Female · Humans · Male · Middle Aged · Peak Expiratory Flow Rate/physiology · Reference Values · Respiratory Function Tests/methods · Respiratory Physiological Phenomena · Sex Factors
Card 2 — Sancho 2004: peak cough flow by pneumotachograph vs portable meter in 30 healthy subjects and 32 neuromuscular patients — overall agreement r = 0.95, but the meter overestimated flows below 270 L/min
Study: Human physiological study (device agreement, healthy N = 30 plus patient limb), Am J Phys Med Rehabil 2004
Population: 30 healthy subjects and 32 medically stable patients with neuromuscular disease (62 people in total); every subject performed maximal cough efforts from total lung capacity through an oronasal mask connected, in randomised order, to a pneumotachograph and to a portable peak flow meter (asmaPLAN+, Vitalograph). The healthy N is 30 — printed plainly; the agreement statistics below are for the combined study population as the record reports them.
Summary: Sancho 2004: peak cough flow by pneumotachograph vs portable meter in 30 healthy subjects and 32 neuromuscular patients — overall agreement r = 0.95, but the meter overestimated flows below 270 L/min
Result: Peak cough flow by pneumotachograph was 377.70 ± 179.28 L/min and by portable meter 377.50 ± 172.98 L/min (not significant), with the two measurements correlated at r = 0.95 (P < 0.001) and a random error of 9.37%; the mean difference was 0.20 L/min with limits of agreement of ±109.78 L/min. Across flow ranges there were no significant differences overall — except below 270 L/min, where in 14 patients the meter read significantly higher than the pneumotachograph (213.93 ± 55.92 vs 180.86 ± 57.22 L/min, P < 0.01). The authors conclude the portable meter is reproducible and reasonably accurate above 270 L/min, with caution required at lower flows.
Watch out: The headline means pool healthy subjects and neuromuscular patients exactly as the record reports them — they are agreement data, not healthy norms; and the low-flow over-reading occurred in patients, which is precisely the range where neuromuscular thresholds are applied, so the caution lands where it matters most.
Source: Sancho J et al. Comparison of peak cough flows measured by pneumotachograph and a portable peak flow meter. Am J Phys Med Rehabil. 2004. PMID: 15277962. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Cough/physiopathology · Female · Flowmeters · Humans · Male · Middle Aged · Neuromuscular Diseases/physiopathology · Peak Expiratory Flow Rate
Card 3 — Mootassim-Billah 2025: in 40 healthy participants (N = 40), voluntary throat clearing produced significantly lower peak expiratory flow and expired volume than voluntary cough and induced reflexive cough (P < 0.001)
Study: Human physiological study (healthy-volunteer cough and throat-clearing airflow, N = 40), Int J Lang Commun Disord 2025
Population: 40 healthy participants; airflow measured for single voluntary throat clearings, single voluntary coughs and the first two induced reflexive coughs of a reflexive cough epoch, as peak expiratory flow rate (L/s) and cough expired volume (L) per manoeuvre. N = 40 — a small healthy-volunteer study, printed plainly. Registered as ISRCTN16540497.
Summary: Mootassim-Billah 2025: in 40 healthy participants (N = 40), voluntary throat clearing produced significantly lower peak expiratory flow and expired volume than voluntary cough and induced reflexive cough (P < 0.001)
Result: Voluntary throat clearing displayed lower airflow feature values than both voluntary cough and induced reflexive cough (P < 0.001 for the comparisons) — throat clearing is aerodynamically a distinct, weaker airway-protective manoeuvre, not a quiet cough, even though the two can be confused by ear during a clinical swallowing evaluation. The record's abstract reports the direction and significance of the differences rather than the absolute flow values, so none is claimed here.
Watch out: N = 40, exploratory by the authors' own description, and framed around dysphagia assessment — its contribution here is the within-person manoeuvre comparison in healthy people, not a normative flow distribution.
Source: Mootassim-Billah S et al. Airflow Features Obtained From Voluntary Throat Clearing Compared to Voluntary Cough and Induced Reflexive Cough in a Healthy Population. Int J Lang Commun Disord. 2025. PMID: 41246892. Registry ID: ISRCTN16540497, from the record's databank fields. MeSH: Humans · Cough/physiopathology · Male · Female · Adult · Pharynx/physiology · Deglutition/physiology · Young Adult · Healthy Volunteers · Reflex/physiology · Middle Aged · Peak Expiratory Flow Rate/physiology
Card 4 — Synthesis: the honest state of cough-flow physiology — three small studies, device agreement that fails exactly at the clinically decisive low flows, and no normative programme behind the thresholds in routine use
Study: Synthesis
Population: Synthesis of the three carded human studies above (Feinstein 2017, N = 52; Sancho 2004, healthy N = 30; Mootassim-Billah 2025, N = 40), framed by Guyton & Hall ch. 37 and Boron & Boulpaep as textbook framing.
Summary: Synthesis: the honest state of cough-flow physiology — three small studies, device agreement that fails exactly at the clinically decisive low flows, and no normative programme behind the thresholds in routine use
Result: What is actually known: cough peak airflow scales with height and differs by sex, peak pressure is greater in men, and the glottal compression-to-expulsive timing (expiratory rise time) is longer in women (Feinstein). A portable peak-flow meter reproduces pneumotachograph peak cough flow well at higher flows (r = 0.95 overall) but over-reads below 270 L/min (Sancho) — the very range in which neuromuscular cough thresholds are applied. And the manoeuvre matters: throat clearing is not a weak cough but a measurably different, lower-flow act (Mootassim-Billah). What is not known is just as definite: no large, multi-population, GLI-style reference programme for cough flow exists in the carded literature, so every 'normal peak cough flow' figure in clinical use traces back to small volunteer samples like these three (combined healthy N = 122). This shelf is stamped PHYSIOLOGY — EMERGING for exactly that reason.
Watch out: Do not cite this shelf as normative reference values: two of its three records do not print absolute healthy flow distributions in their abstracts, and the third is a device-agreement study. It documents the structure of the evidence and its thinness — a builder with full texts could deepen it, but the thin-base warning would remain.
Source: Synthesis of Feinstein AJ et al., Ann Otol Rhinol Laryngol 2017 (PMID: 28397558); Sancho J et al., Am J Phys Med Rehabil 2004 (PMID: 15277962); Mootassim-Billah S et al., Int J Lang Commun Disord 2025 (PMID: 41246892). Registry IDs as on the individual cards.