SourceMed · Shelf #7163 in the ask interface

Left-ventricular global longitudinal strain: normal values by speckle-tracking echocardiography

Shelf #7163 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — ESTABLISHED — healthy global longitudinal strain centres at about −19.7% (2D meta-analysis, 2,597 subjects) and −19.05% (3D meta-analysis, 2,346 subjects), with NORRE lower reference limits of −16.7% (men) and −17.8% (women); software and blood pressure are established modifiers, so no platform-free cut-off is claimed

Stamped: 2026-11-28.

Evidence published: 2013–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, what are normal left-ventricular global longitudinal strain values by speckle-tracking echocardiography — the meta-analytic normal range, the EACVI NORRE reference ranges, and how much do vendor, sex and age shift them?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED for the central range, with vendor dependence as a core caveat (textbook framing: Guyton & Hall, cardiac muscle / ventricular function; strain imaging itself is textbook-thin, as the slate row directs, and the shelf rests on the primary measurement literature). Two meta-analyses and one large multicentre reference study converge on the same centre: mean left-ventricular global longitudinal strain (GLS) in healthy adults is about −19% to −20% (2D meta-analysis: −19.7%, with study means spanning −15.9% to −22.1%; 3D meta-analysis: −19.05%, study means −15.8% to −23.4%). The EACVI NORRE study (549 healthy volunteers, vendor-independent analysis software) puts the lowest expected value at −16.7% in men and −17.8% in women — that is, a healthy GLS is generally more negative than about −17%. What is NOT settled is a single universal cut-off: between-study heterogeneity is very high (I² ≈ 99% in the 3D analysis), analysis software was consistently associated with the reported values, and systolic blood pressure — not age, sex, frame rate or equipment — tracked GLS variation in the 2D meta-regression. So the honest summary is a centre (about −19.5%), a lower reference boundary (about −17% by NORRE), and a standing instruction to interpret a value beside its vendor/software and the patient's blood pressure, never against one universal number.

MeSH: Reference Values · Echocardiography/methods · Ventricular Function, Left/physiology · Healthy Volunteers · Sex Factors · Age Factors

Cards (4)

Card 1 — Yingchoncharoen 2013 meta-analysis (2,597 subjects, 24 studies): normal 2D GLS mean −19.7% (95% CI −20.4 to −18.9), study means spanning −15.9% to −22.1%

Study: Meta-analysis of normal 2D strain ranges (Yingchoncharoen 2013)

Population: 2,597 healthy normal subjects pooled from 24 studies reporting left-ventricular strain by two-dimensional speckle-tracking echocardiography (searched through August 2011); effects of demographic, haemodynamic and equipment variables were sought by meta-regression.

Summary: Yingchoncharoen 2013 meta-analysis (2,597 subjects, 24 studies): normal 2D GLS mean −19.7% (95% CI −20.4 to −18.9), study means spanning −15.9% to −22.1%

Result: Reported normal GLS values varied from −15.9% to −22.1% (mean, −19.7%; 95% CI, −20.4% to −18.9%). Normal global circumferential strain varied from −20.9% to −27.8% (mean, −23.3%; 95% CI, −24.6% to −22.1%) and global radial strain from 35.1% to 59.0% (mean, 47.3%; 95% CI, 43.6% to 51.0%). There was significant between-study heterogeneity; in meta-regression, blood pressure — but not age, gender, frame rate or equipment — was associated with variation in normal GLS values.

Watch out: A mean of −19.7% with study means spread over six percentage points is a centre, not a cut-off: an individual laboratory's healthy range can sit well inside or outside another's, and the blood-pressure association means a GLS read without the day's systolic pressure is only half-interpreted.

Source: Yingchoncharoen T et al. Normal ranges of left ventricular strain: a meta-analysis. Journal of the American Society of Echocardiography. 2013. PMID: 23218891. Registry ID: none in the record. MeSH: Echocardiography/standards,statistics & numerical data · Elastic Modulus/physiology · Elasticity Imaging Techniques/standards,statistics & numerical data · Heart Ventricles/diagnostic imaging · Humans · Internationality · Reference Values · Reproducibility of Results · Sensitivity and Specificity · Ventricular Function, Left/physiology

Card 2 — Truong 2019 3D meta-analysis (2,346 subjects, 33 datasets): normal 3D GLS mean −19.05%, but heterogeneity I² = 99% and analysis software significantly shifted every strain value

Study: Systematic review and meta-analysis of normal 3D strain ranges (Truong 2019)

Population: 2,346 healthy subjects pooled from 33 datasets reporting left-ventricular strain by three-dimensional speckle-tracking echocardiography (searches through January 2019); demographic, clinical and vendor variables assessed by meta-regression.

Summary: Truong 2019 3D meta-analysis (2,346 subjects, 33 datasets): normal 3D GLS mean −19.05%, but heterogeneity I² = 99% and analysis software significantly shifted every strain value

Result: Normal mean GLS across studies varied from −15.80% to −23.40% (mean, −19.05%; 95% CI, −18.18% to −19.93%; I² = 99.0%). Global circumferential strain mean was −22.42%, global radial strain 47.48% and global area strain −35.03%, all with I² above 99%. Software for strain analysis was consistently associated with variations in normal strain values (GLS: P = .016; GCS: P < .001; GRS: P < .001; GAS: P < .001).

Watch out: Three-dimensional and two-dimensional strain are different measurements and their ranges must not be interchanged; with I² at 99%, the pooled mean describes the literature's centre, while any single patient's classification still depends on the local platform and software version.

Source: Truong VT et al. Normal Ranges of Left Ventricular Strain by Three-Dimensional Speckle-Tracking Echocardiography in Adults: A Systematic Review and Meta-Analysis. Journal of the American Society of Echocardiography. 2019. PMID: 31611158. Registry ID: none in the record. MeSH: Adult · Echocardiography, Three-Dimensional/methods · Female · Healthy Volunteers · Heart Ventricles/diagnostic imaging · Humans · Image Processing, Computer-Assisted · Male · Middle Aged · Reference Values · Reproducibility of Results · Ventricular Function, Left/physiology

Card 3 — Sugimoto 2017 EACVI NORRE study (549 healthy volunteers, 22 centres): lowest expected longitudinal strain −16.7% in men and −17.8% in women with vendor-independent software

Study: Multicentre reference-range study, EACVI NORRE (Sugimoto 2017)

Population: 549 healthy subjects (mean age 45.6 ± 13.3 years) enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study; all 2D datasets were analysed with one vendor-independent software package to allow homogeneous measurement across equipment.

Summary: Sugimoto 2017 EACVI NORRE study (549 healthy volunteers, 22 centres): lowest expected longitudinal strain −16.7% in men and −17.8% in women with vendor-independent software

Result: The lowest expected values of LV strain (mean ± 1.96 SD) were −16.7% in men and −17.8% in women for longitudinal strain, −22.3% and −23.6% for circumferential strain, 20.6% and 21.5% for radial strain, and 2.2 and 1.9 degrees for twist. In multivariable analysis, longitudinal strain decreased with age while circumferential and radial strain moved oppositely, and male gender was associated with lower strain values. Inter-vendor differences persisted for circumferential and radial strain despite the vendor-independent software, but importantly no inter-vendor differences were noted in longitudinal strain.

Watch out: NORRE's harmonised analysis is the best-case scenario — one software package for all comers — and real-world laboratories using vendor-native software should expect wider scatter than NORRE's limits imply, particularly for circumferential and radial strain, where vendor differences survived even here.

Source: Sugimoto T et al. Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study. European heart journal. Cardiovascular Imaging. 2017. PMID: 28637227. Registry ID: none in the record. MeSH: Adult · Age Factors · Echocardiography/methods · Europe · Female · Healthy Volunteers · Heart Ventricles/diagnostic imaging · Humans · Image Processing, Computer-Assisted · Linear Models · Male · Middle Aged · Multivariate Analysis · Observer Variation · Reference Values · Sex Factors · Ventricular Function, Left/physiology

Card 4 — Synthesis: healthy GLS centres on about −19% to −20%, with a NORRE lower reference boundary near −17%; software/vendor and blood pressure move the value, so no single universal cut-off exists

Study: Synthesis

Population: Synthesis of the carded reports: the 2D meta-analysis (2,597 subjects, 24 studies), the 3D meta-analysis (2,346 subjects, 33 datasets) and the EACVI NORRE reference study (549 healthy volunteers, 22 centres).

Summary: Synthesis: healthy GLS centres on about −19% to −20%, with a NORRE lower reference boundary near −17%; software/vendor and blood pressure move the value, so no single universal cut-off exists

Result: The three records agree on the centre (mean GLS −19.7% by 2D, −19.05% by 3D) and NORRE supplies sex-specific lower limits (−16.7% men, −17.8% women) obtained under harmonised analysis. They also agree on the caveats: heterogeneity is extreme, analysis software significantly shifts values, and systolic blood pressure tracks GLS. PHYSIOLOGY — ESTABLISHED for the central range and its lower boundary under stated platform conditions; a platform-free universal threshold is explicitly not claimed.

Watch out: A further strain synthesis located during building had an empty abstract in PubMed and was not used, in line with the rule that unverifiable records are not carded. Serial measurements in one patient should stay on one platform and software version; a change of vendor can manufacture an apparent change in GLS.

Source: Synthesis of Yingchoncharoen T et al. Journal of the American Society of Echocardiography. 2013 (PMID: 23218891); Truong VT et al. Journal of the American Society of Echocardiography. 2019 (PMID: 31611158); Sugimoto T et al. European heart journal. Cardiovascular Imaging. 2017 (PMID: 28637227), all carded above. Textbook framing: Guyton & Hall Textbook of Medical Physiology (cardiac muscle / ventricular function) — thin for strain imaging; the shelf rests chiefly on the primary measurement literature.