SourceMed · Shelf #7179 in the ask interface
Peripapillary RNFL thickness on SD-OCT: ~87–105 μm by cohort and device, thinning 0.38 μm/year
Shelf #7179 · Eyes, skin, nose & allergy
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2009–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy eyes, what is peripapillary retinal nerve fibre layer thickness on spectral-domain OCT — its mean and 1st/5th-percentile limits by age, sex, ethnicity and optic-disc size — and how fast does it thin with normal ageing?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED — framed by Ganong on vision / retinal structure (thin framing for OCT biometry — this shelf rests chiefly on the primary measurement literature, as its slate row directs), and resting on three primary SD-OCT records plus a 617-subject interocular-symmetry cohort: across the European Eye Epidemiology consortium's eight cohorts (16,084 adults), mean peripapillary RNFL thickness ranged from 86.8 ± 21.4 μm (Rotterdam Study I) to 104.7 ± 12.5 μm (Rotterdam Study III), thinning with age at −0.38 μm per year; the Cirrus-versus-Stratus comparison (97 healthy subjects) shows device values are not interchangeable (proportional bias, and Cirrus intervisit reproducibility 4.31–22.01 μm); and in 103 healthy myopic participants the RNFL bundle pattern itself shifts with axial length, changing how maps must be read. Percentile limits are device-normative-database constructs, not biological constants. Cross-point in prose: the companion macular-thickness question (slate row S9-4-39) is the sibling OCT metric and is carded separately — it is not merged into this shelf.
MeSH: Nerve Fibers/pathology · Tomography, Optical Coherence/methods · Optic Disk/pathology · Reference Values · Retinal Ganglion Cells/pathology
Cards (5)
Card 1 — Mauschitz 2018 (E3): in 16,084 European adults across 8 cohorts, mean peripapillary RNFL thickness ranged from 86.8 ± 21.4 μm to 104.7 ± 12.5 μm, thinning by 0.38 μm per year of age
Study: Human cross-sectional meta-analysis (E3 consortium, SD-OCT), Ophthalmology 2018
Population: 16,084 European adults from 8 cohort studies of the European Eye Epidemiology (E3) consortium (mean age range across cohorts 56.9 ± 12.3 to 82.1 ± 4.2 years), in a cross-sectional meta-analysis of peripapillary RNFL thickness measured by spectral-domain OCT, with associations examined by multivariable linear regression per study and pooled by random-effects meta-analysis.
Summary: Mauschitz 2018 (E3): in 16,084 European adults across 8 cohorts, mean peripapillary RNFL thickness ranged from 86.8 ± 21.4 μm to 104.7 ± 12.5 μm, thinning by 0.38 μm per year of age
Result: Mean peripapillary RNFL thickness ranged from 86.8 ± 21.4 μm in the Rotterdam Study I to 104.7 ± 12.5 μm in the Rotterdam Study III. Reduced thickness was associated with older age (β = −0.38 μm/year; 95% CI −0.57 to −0.18), higher intraocular pressure (β = −0.36 μm/mmHg), visual impairment (β = −5.50 μm), and history of systemic hypertension (β = −0.54 μm) and stroke (β = −1.94 μm). Higher thickness was associated with more hyperopic spherical equivalent (β = 1.39 μm/diopter) and with current smoking (β = 1.53 μm versus never-smokers). The age slope implies about 3.8 μm of thinning per decade — arithmetic on the reported β, printed as such.
Watch out: Older European adults (mean cohort ages 57–82) with a mix of platforms across cohorts — the 86.8–104.7 μm range is a between-cohort range, not a single population's reference interval, and the smoking association (thicker RNFL in smokers) is an observational association, not a protective effect.
Source: Mauschitz MM et al. Systemic and Ocular Determinants of Peripapillary Retinal Nerve Fiber Layer Thickness Measurements in the European Eye Epidemiology (E3) Population. Ophthalmology. 2018. PMID: 29716786. Registry ID: none in the record. MeSH: Cross-Sectional Studies · Disease Progression · Europe/epidemiology · Glaucoma/diagnosis,epidemiology,physiopathology · Humans · Intraocular Pressure/physiology · Nerve Fibers/pathology · Optic Disk/pathology · Population Surveillance/methods · Retinal Ganglion Cells/pathology · Tomography, Optical Coherence/methods
Card 2 — Leung 2009: Cirrus HD-OCT versus Stratus OCT in 97 healthy subjects — Cirrus intravisit repeatability 5.12–15.02 μm, intervisit 4.31–22.01 μm, with proportional bias between devices
Study: Human device-comparison study (Cirrus SD-OCT vs Stratus TD-OCT), Ophthalmology 2009
Population: 97 normal subjects and 83 glaucoma patients in a prospective cross-sectional study, one eye each imaged with a spectral-domain OCT device (Cirrus HD-OCT; Carl Zeiss Meditec, named as published) and a time-domain OCT device (Stratus OCT; Carl Zeiss Meditec, named as published); 16 and 31 normal eyes were selected randomly to evaluate intravisit repeatability and intervisit reproducibility respectively, with agreement by Bland–Altman plots and diagnostic performance by area under the receiver operating characteristic curve.
Summary: Leung 2009: Cirrus HD-OCT versus Stratus OCT in 97 healthy subjects — Cirrus intravisit repeatability 5.12–15.02 μm, intervisit 4.31–22.01 μm, with proportional bias between devices
Result: Intravisit repeatability of Cirrus HD-OCT ranged between 5.12 and 15.02 μm, and intervisit reproducibility between 4.31 and 22.01 μm. Intervisit variabilities of sectoral and average RNFL thicknesses were lower for Cirrus than Stratus, significantly so at 1, 3, 4 and 8–11 o'clock (P ≤ 0.021). There were proportional biases between the two devices: the difference in RNFL thicknesses increased with the means. Diagnostic performance was comparable (average RNFL area under the curve 0.962 for Cirrus, 0.956 for Stratus) and the structure–function association comparable (R² = 0.580 vs 0.623).
Watch out: The record's abstract reports variability and diagnostic performance, not a mean healthy RNFL thickness — none is printed from this card; its role is the device lesson, and the glaucoma patients (83) are the diagnostic-performance contrast, not healthy norms.
Source: Leung CK et al. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology. 2009. PMID: 19464061. Registry ID: none in the record. MeSH: Algorithms · Area Under Curve · Cross-Sectional Studies · Female · Glaucoma, Angle-Closure/diagnosis · Glaucoma, Open-Angle/diagnosis · Humans · Imaging, Three-Dimensional · Intraocular Pressure/physiology · Male · Middle Aged · Nerve Fibers/pathology · Optic Disk/pathology · Optic Nerve Diseases/diagnosis · Prospective Studies · Reproducibility of Results · Retinal Ganglion Cells/pathology · Sensitivity and Specificity · Time Factors · Tomography, Optical Coherence · Visual Acuity/physiology · Visual Fields/physiology
Card 3 — Leung 2012: in 103 healthy myopic participants (189 eyes), the RNFL bundles converge temporally with axial length — and the area of abnormal RNFL measurement grows with it
Study: Human SD-OCT study (healthy myopic eyes), Invest Ophthalmol Vis Sci 2012
Population: 189 myopic eyes from 103 normal healthy myopic participants, imaged by spectral-domain OCT; the angle between the long axes of the superotemporal and inferotemporal RNFL bundles (the RNFL distribution angle) and the abnormal area in the RNFL thickness deviation map were measured, with associations analysed by linear mixed models.
Summary: Leung 2012: in 103 healthy myopic participants (189 eyes), the RNFL bundles converge temporally with axial length — and the area of abnormal RNFL measurement grows with it
Result: The RNFL distribution angle decreased with axial length (P < 0.011). In univariate analysis the area of abnormal RNFL measurement was positively associated with axial length (P = 0.001) and negatively associated with the RNFL distribution angle (P < 0.001), average RNFL thickness (P < 0.001), optic disc area (P ≤ 0.001) and signal strength (P = 0.026); in multivariate analysis it was negatively associated with the RNFL distribution angle independent of the other covariates. The superotemporal and inferotemporal bundles converge temporally with increasing myopia, which was associated with an increase in the area of abnormal RNFL measurement — so interpreting an RNFL map in a myopic eye requires accounting for the bundle distribution pattern.
Watch out: Myopic eyes only, retrospective, one device family: 'abnormal area' here means area flagged against the device's normative database in healthy myopes — a false-positive signal, not disease — and no mean RNFL thickness is printed from this record.
Source: Leung CK et al. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: interpreting the RNFL maps in healthy myopic eyes. Investigative Ophthalmology & Visual Science. 2012. PMID: 22997288. Registry ID: none in the record. MeSH: Adult · Follow-Up Studies · Humans · Middle Aged · Myopia/pathology · Optic Disk/pathology · Refraction, Ocular · Retinal Ganglion Cells/pathology · Retrospective Studies · Tomography, Optical Coherence/methods · Young Adult
Card 4 — Hwang 2014: in 617 healthy subjects (1,234 eyes) on Cirrus SD-OCT, the normal interocular difference limit (2.5th–97.5th percentile) was 9.5 μm globally — a percentile construct, not a biological constant
Study: Human normative study (interocular symmetry, Cirrus SD-OCT), Clin Exp Optom 2014
Population: 1,234 healthy eyes from 617 subjects (mean age 36.4 ± 19.8 years, range 5–80; mean refractive error −2.67 ± 2.91 D, range −14.13 to +5.75 D), with peripapillary RNFL thickness measured by Cirrus high-definition spectral-domain OCT (named as published); interocular differences (right minus left) in global and quadrant thicknesses were measured, with effects of age and refractive error examined.
Summary: Hwang 2014: in 617 healthy subjects (1,234 eyes) on Cirrus SD-OCT, the normal interocular difference limit (2.5th–97.5th percentile) was 9.5 μm globally — a percentile construct, not a biological constant
Result: Cut-off limits for normal interocular RNFL thickness differences (2.5th and 97.5th percentiles of normative data) in the global area and in the superior, nasal, inferior and temporal quadrants were 9.5, 23.0, 15.6, 20.0 and 22.6 μm respectively. Mean interocular differences were 0.7 (P < 0.001), −3.9 (P < 0.001), 2.6 (P < 0.001), 1.1 (P = 0.007) and 3.0 μm (P < 0.001) in the global, superior, nasal, inferior and temporal areas. Interocular differences were not significantly correlated with age or refractive error.
Watch out: One device (Cirrus), one population, wide refractive range — the 9.5 μm global limit is that device's normative-database percentile cut-off for that population, and the quadrant limits are far wider (up to 23.0 μm superiorly), so a global limit must not be applied quadrant by quadrant.
Source: Hwang YH et al. Interocular symmetry of retinal nerve fibre layer thickness in healthy eyes: a spectral-domain optical coherence tomographic study. Clinical & Experimental Optometry. 2014. PMID: 25331078. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Child, Preschool · Female · Humans · Male · Middle Aged · Nerve Fibers · Optic Disk/cytology · Reference Values · Refractive Errors/diagnosis · Retinal Ganglion Cells/cytology · Tomography, Optical Coherence/methods · Young Adult
Card 5 — Synthesis: peripapillary RNFL thickness centres at roughly 87–105 μm depending on cohort and device, thins about 0.38 μm per year, and is a device-relative measurement — read the map against the right normative database
Study: Synthesis
Population: Synthesis of the four carded human records (the 16,084-adult E3 meta-analysis; the 97-healthy-subject Cirrus-vs-Stratus comparison; the 103 healthy myopic participants; and the 617-subject interocular-symmetry cohort), framed by Ganong on vision / retinal structure — thin framing for OCT biometry, as the row states.
Summary: Synthesis: peripapillary RNFL thickness centres at roughly 87–105 μm depending on cohort and device, thins about 0.38 μm per year, and is a device-relative measurement — read the map against the right normative database
Result: Mean peripapillary RNFL thickness on spectral-domain OCT sits in the high-80s to mid-100s of micrometres (86.8 ± 21.4 to 104.7 ± 12.5 μm across E3 cohorts), with the cohort and the device doing much of the moving: Cirrus and Stratus values show proportional bias and are not interchangeable, and Cirrus sectoral reproducibility alone spans 4.31–22.01 μm between visits. Age thins the layer at −0.38 μm/year (about 3.8 μm per decade, arithmetic on the reported slope), higher intraocular pressure and vascular history thin it further, and hyperopia thickens it. In myopic eyes the bundle geometry itself changes — bundles converge temporally with axial length, and the area flagged 'abnormal' against a normative database grows — so a map must be read with refraction and disc size in mind. The percentile limits printed here (e.g. a 9.5 μm normal interocular difference globally on Cirrus) are constructs of a device's normative database, not biological constants. The companion macular-thickness question (slate row S9-4-39) is a separate OCT metric, carded separately, not merged here.
Watch out: No carded record here gives 1st/5th-percentile RNFL limits by sex and ethnicity as a single table, and the E3 cohorts are European adults with mean ages 57–82 — the shelf therefore gives the age slope and the cohort range, the device lesson, and one device's percentile construction, rather than a universal centile table that no fetched record supports.
Source: Synthesis of Mauschitz MM et al. Ophthalmology. 2018 (PMID: 29716786); Leung CK et al. Ophthalmology. 2009 (PMID: 19464061); Leung CK et al. Investigative Ophthalmology & Visual Science. 2012 (PMID: 22997288); Hwang YH et al. Clinical & Experimental Optometry. 2014 (PMID: 25331078), all carded above, with Ganong textbook framing. Registry ID: none in the record. MeSH: not captured from the record