In stable, uncomplicated type B dissection, does pre-emptive thoracic endovascular repair plus medical therapy beat medical therapy alone over five years?

Balance of the evidence

POSSIBLE: INSTEAD-XL's 5-year analysis of 140 randomised patients found aorta-specific mortality lower with stent-grafting plus medical therapy than with medical therapy alone (6.9% vs 19.3%; P=0.04), with all-cause mortality not significantly different (11.1% vs 19.3%; P=0.13) — mortality figures always printed in pairs on this shelf. But the long-term analysis rests on landmark analyses of a small trial, and the second randomised trial, ADSORB (61 patients), showed only a 1-year remodelling benefit with no deaths in either arm at 30 days and one death by 1 year in the stent group. Two small trials, one surrogate and one fragile long-term signal: POSSIBLE, Tier C,. Aneurysm repair (EVAR) is Shelf #553, a different disease, and is not re-carded here.

MeSH: Aortic Dissection/mortality,pathology,surgery · Aorta, Thoracic/pathology · Aortic Aneurysm, Thoracic/mortality,pathology,surgery · Blood Vessel Prosthesis Implantation/methods · Disease Progression · Proportional Hazards Models · Stents

Cards (3)

Card 1 — INSTEAD-XL 2013: at 5 years, aorta-specific mortality was 6.9% with stent-graft plus medical therapy vs 19.3% with medical therapy alone; all-cause mortality 11.1% vs 19.3% (not significant)

Study: Long-term (5-year) analysis of a randomised trial, with landmark analyses of years 2–5

Population: 140 patients with stable type B aortic dissection previously randomised to optimal medical treatment plus thoracic endovascular repair (72) or optimal medical treatment alone (68); analyses intention-to-treat. The abstract does not state mean age.

Summary: INSTEAD-XL 2013: at 5 years, aorta-specific mortality was 6.9% with stent-graft plus medical therapy vs 19.3% with medical therapy alone; all-cause mortality 11.1% vs 19.3% — the two printed together.

Result: At 5 years the risk of aorta-specific mortality was 6.9% with stent-grafting vs 19.3% with medical therapy alone (P=0.04); all-cause mortality was 11.1% vs 19.3% (P=0.13) — the two mortality figures printed together, as this library requires. Disease progression was 27.0% vs 46.1% (P=0.04). Landmark analysis of years 2–5 suggested benefit on all end points (for example all-cause mortality 0% vs 16.9%, P=0.0003, and aorta-specific mortality 0% vs 16.9%, P=0.0005, in that window). Improved survival and less progression were associated with stent-graft-induced false-lumen thrombosis, present in 90.6% of cases.

Watch out: A 140-patient trial whose late benefit emerges in landmark (survivor-window) analyses: patients had to survive the early period to enter the window in which the benefit appears, and the headline all-cause mortality difference is not significant. This is a signal to weigh in selected anatomy, not proof for all uncomplicated dissections.

Source: Nienaber CA et al. Endovascular Repair of Type B Aortic Dissection: Long-Term Results of the Randomized Investigation of Stent Grafts in Aortic Dissection Trial. Circ Cardiovasc Interv. 2013;6(4):407-416. PMID: 23922146. Registry ID: ClinicalTrials.gov NCT01415804, from the record's databank fields.

Card 2 — ADSORB 2014: stent-grafting remodelled the aorta at 1 year (incomplete false-lumen thrombosis 43% vs 97%) but the trial was far too small for mortality — one death, in the stent group

Study: Prospective randomised trial (best medical treatment vs best medical treatment plus stent graft)

Population: 61 patients with acute uncomplicated type B aortic dissection of less than 14 days' history (80% DeBakey type IIIB), randomised to medical treatment alone (31) or medical treatment plus a Gore TAG stent graft (30); mean age 63 years in both groups; rupture, impending rupture and malperfusion were exclusions.

Summary: ADSORB 2014: stent-grafting remodelled the aorta at 1 year (incomplete false-lumen thrombosis 43% vs 97%) but the trial was far too small for mortality.

Result: The primary end point (incomplete or no false-lumen thrombosis, aortic dilatation, or aortic rupture at 1 year) favoured the stent group (P<0.001 for the overall end point): incomplete false-lumen thrombosis was found in 13 of the stent group (43%) vs 30 of the medical group (97%) (P<0.001), the false lumen shrank with the stent and grew without it, and the true lumen increased only in the stent group. In the first 30 days there were no deaths in either group; three medical-group patients crossed over to stent-grafting for disease progression within a week. By 1 year, one death had occurred — in the stent-graft group — alongside two further medical-group failures (one malperfusion, one aneurysm formation).

Watch out: A 61-patient, 1-year remodelling trial: every clinical figure in it is a handful of events, and its only death fell in the stent arm. It supports the mechanism (false-lumen thrombosis and remodelling) behind INSTEAD-XL's late signal; it cannot support a survival claim of its own — mortality is printed beside its remodelling figures for exactly that reason.

Source: Brunkwall J et al. Endovascular Repair of Acute Uncomplicated Aortic Type B Dissection Promotes Aortic Remodelling: 1 Year Results of the ADSORB Trial. Eur J Vasc Endovasc Surg. 2014;48(3):285-291. PMID: 24962744. Registry ID: ClinicalTrials.gov NCT00742274, from the record's databank fields.

Card 3 — Synthesis: remodelling is proven, the late aorta-specific survival edge is a small-trial signal — POSSIBLE, proposed (Tier C)

Study: Synthesis

Population: Synthesis of the cards above: INSTEAD-XL (140 patients, 5 years) and ADSORB (61 patients, 1 year).

Summary: Remodelling is proven, the late aorta-specific survival edge is a small-trial signal — POSSIBLE.

Result: The mechanistic half is solid across both trials: a stent graft thromboses and shrinks the false lumen (43% vs 97% incomplete thrombosis at 1 year in ADSORB; 90.6% false-lumen thrombosis in INSTEAD-XL's stent arm). The clinical half is one trial's late landmark signal (aorta-specific mortality 6.9% vs 19.3% at 5 years, all-cause 11.1% vs 19.3% and not significant). POSSIBLE is the honest stamp, and the shelf is Tier C and because the claim that matters is aorta-related mortality.

Watch out: 'Uncomplicated' is doing heavy work: both trials excluded rupture, impending rupture and malperfusion. Nothing here applies to complicated dissection, where intervention is not elective.

Source: Synthesis of Nienaber CA et al. Circ Cardiovasc Interv. 2013;6(4):407-416. PMID: 23922146; Brunkwall J et al. Eur J Vasc Endovasc Surg. 2014;48(3):285-291. PMID: 24962744. Registry IDs as on the individual cards.