SourceMed · Shelf #7180 in the ask interface

Macular thickness in health is a device number: Spectralis central subfield ~270 µm (ceiling 315 µm), swept-source ~228 µm in the same population, Cirrus ~241 µm in children — conversion equations exist because raw values differ

Shelf #7180 · Eyes, skin, nose & allergy

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 2009–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy eyes, what is macular thickness on spectral-domain OCT — central subfield and ETDRS-sector means by age, sex and ethnicity — and how reproducible are the measurements?

Balance of the evidence

Textbook framing (Ganong's Review of Medical Physiology, vision/retinal structure) is thin for OCT biometry, as the slate row states — the primary measurement literature carries this shelf. Healthy macular thickness is a device-relative quantity. On Spectralis spectral-domain OCT, 50 healthy adults gave a central subfield (CSF) mean of 270.2 µm (SD 22.5) and central point thickness of 227.3 µm, with a proposed normal CSF ceiling of 315 µm and no significant age or sex effect (Grover 2009). The same retinas measure differently on other platforms: in 290 normal Chinese eyes, swept-source OCT read CSF at 227.8 µm where spectral-domain read 260.0 µm (Xiong 2021), and an 11-site international cohort of 546 healthy controls derived explicit Spectralis-to-Cirrus conversion equations for retinal layer thicknesses, with layer thinning after age 40 of 2.4 µm per decade (peripapillary RNFL) and 1.4 µm per decade (macular GCIPL) (Kenney 2022). Cirrus norms in healthy children give CSF 240.6 µm (Raffa 2023). The companion peripapillary RNFL thickness question is homed on the sibling shelf (slate row S9-4-38) and is cross-pointed here in prose only. PHYSIOLOGY — ESTABLISHED.

MeSH: Adult · Aged · Aged, 80 and over · Aging/physiology · Body Weights and Measures · Female · Fourier Analysis · Humans · Intraocular Pressure/physiology · Macula Lutea/anatomy & histology · Male · Middle Aged · Prospective Studies · Reference Values · Tomography, Optical Coherence/methods · Visual Acuity/physiology · Young Adult · Cross-Sectional Studies · Diabetic Retinopathy/diagnosis · Healthy Volunteers · Macula Lutea/diagnostic imaging,pathology · Organ Size · Adolescent · Nerve Fibers · Retinal Ganglion Cells · Multiple Sclerosis/diagnostic imaging · Child · Optic Disk/diagnostic imaging · Retrospective Studies · Saudi Arabia

Cards (5)

Card 1 — Spectralis normative macular thickness (N = 50 healthy adults): central point 227.3 µm, central subfield 270.2 µm — proposed normal central-subfield ceiling 315 µm (Grover 2009)

Study: Primary human physiology study (normative Spectralis SD-OCT macular thickness)

Population: 50 subjects aged 20-84 years with no known retinal disease, best-corrected acuity 20/20 and normal intraocular pressure, in three age groups (20-40, 41-60, 61+ years); Spectralis high-definition spectral-domain OCT (Heidelberg Engineering), single operator, right eyes analysed by default.

Summary: Spectralis normative macular thickness (N = 50 healthy adults): central point 227.3 µm, central subfield 270.2 µm — proposed normal central-subfield ceiling 315 µm (Grover 2009)

Result: Mean central point thickness was 227.3 µm (SD 23.2) and mean central subfield (CSF) thickness 270.2 µm (SD 22.5). Of the nine ETDRS subfields the outer nasal quadrant was thickest at 339.5 µm (SD 16.9). Retinal thickness did not differ significantly with age (P = .62) or gender (P = .1); a difference between Black and White subjects was suggested (P = .007). The authors propose 315 µm as the guideline upper value for normal CSF thickness on this device.

Watch out: Single-device, single-centre norms from 50 subjects: the 315 µm ceiling is a Spectralis construct — Cirrus, Topcon and swept-source values for the same retina differ systematically (see the device-comparison cards).

Source: Grover S et al. American journal of ophthalmology. 2009. PMID: 19427616. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Aging/physiology · Body Weights and Measures · Female · Fourier Analysis · Humans · Intraocular Pressure/physiology · Macula Lutea/anatomy & histology · Male · Middle Aged · Prospective Studies · Reference Values · Tomography, Optical Coherence/methods · Visual Acuity/physiology · Young Adult

Card 2 — Same eyes, two machines, ~32 µm apart: swept-source CSF 227.8 µm vs spectral-domain 260.0 µm in 290 normal Chinese eyes — with a derived conversion equation (Xiong 2021)

Study: Primary human physiology study (paired SS-OCT vs SD-OCT macular thickness in healthy and diabetic eyes)

Population: 290 normal eyes (plus diabetic eyes without and with retinopathy) from community residents aged 30-80 years in Guangzhou, China; macular thickness measured on both swept-source OCT (Triton DRI OCT, Topcon) and spectral-domain OCT (Heidelberg Engineering). Devices named as published. Only the normal-eye limb is carded here.

Summary: Same eyes, two machines, ~32 µm apart: swept-source CSF 227.8 µm vs spectral-domain 260.0 µm in 290 normal Chinese eyes — with a derived conversion equation (Xiong 2021)

Result: In normal eyes, mean central subfield thickness was 227.8 µm (SD 19.4) by swept-source OCT versus 260.0 µm (SD 19.7) by spectral-domain OCT (p < .0001) — swept-source values were significantly thinner in every subfield, yet agreement was excellent (all intraclass correlations > 0.9). CSF was thicker in men than women on swept-source (237.2 vs 222.0 µm, p < .0001). Conversion equations relating CSF, central point thickness and macular volume between the devices were derived, with over 95% of predicted values within 10% of actual in the diabetic groups. The authors propose swept-source CSF thresholds of 275 µm (men) and 260 µm (women) as minimum criteria for macular oedema in this population.

Watch out: The ~32 µm CSF gap between platforms on identical eyes is the core lesson: a 'macular thickness' number without its device is uninterpretable, and oedema cut-offs must be device- and sex-specific as the authors set them.

Source: Xiong K et al. Current eye research. 2021. PMID: 33879001. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Diabetic Retinopathy/diagnosis · Female · Healthy Volunteers · Humans · Macula Lutea/diagnostic imaging,pathology · Male · Middle Aged · Organ Size · Prospective Studies · Tomography, Optical Coherence/methods

Card 3 — International healthy cohort (N = 546, 11 sites): Spectralis-to-Cirrus conversion equations for retinal layer thickness, and thinning of about 2.4 µm per decade after age 40 (Kenney 2022)

Study: Primary human physiology study (international normative SD-OCT cohort and cross-device conversion)

Population: 546 healthy controls aged 18-87 years (mean 39.3, SD 14.6; 54% male) at 11 international sites (IMSVISUAL consortium), scanned on Spectralis or Cirrus spectral-domain OCT; a single-site subset was scanned on both devices the same day (346 for the nerve-fibre equation, 228 for the ganglion-cell equation).

Summary: International healthy cohort (N = 546, 11 sites): Spectralis-to-Cirrus conversion equations for retinal layer thickness, and thinning of about 2.4 µm per decade after age 40 (Kenney 2022)

Result: The conversion equations were: Cirrus peripapillary RNFL = -5.0 + (1.0 × Spectralis global value), and Cirrus macular ganglion cell + inner plexiform layer (GCIPL) = -4.5 + (0.9 × Spectralis global value) (standard error 0.02 for both). After age 40, peripapillary RNFL declined by 2.4 µm per decade and GCIPL by 1.4 µm per decade (both P < 0.001, adjusted for sex, race and country). Women had slightly thicker RNFL (2.6 µm, P = 0.003); neither measure was associated with race/ethnicity.

Watch out: This cohort's macular measure is the GCIPL layer, not total central-subfield thickness — it is carded for the conversion equations and the age-decline rates, and must not be read as a source of CSF values; individual measurements remain non-interchangeable between devices, which is why the equations exist.

Source: Kenney R et al. Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society. 2022. PMID: 36049213. Registry ID: none in the record. MeSH: Male · Female · Humans · Adolescent · Young Adult · Adult · Middle Aged · Aged · Aged, 80 and over · Tomography, Optical Coherence/methods · Nerve Fibers · Retinal Ganglion Cells · Cross-Sectional Studies · Multiple Sclerosis/diagnostic imaging

Estimate type: adjusted estimate, as stated in the card.

Card 4 — Cirrus norms in 135 healthy Saudi children: central subfield 240.6 µm, mean macular thickness 275.9 µm — boys' central macula thicker than girls' (Raffa 2023)

Study: Primary human physiology study (normative Cirrus OCT in healthy children)

Population: 135 full-term healthy Saudi children aged 4-18 years at a university hospital ophthalmology clinic; Cirrus high-definition OCT normative data for macula, retinal nerve fibre layer and optic nerve head (retrospective).

Summary: Cirrus norms in 135 healthy Saudi children: central subfield 240.6 µm, mean macular thickness 275.9 µm — boys' central macula thicker than girls' (Raffa 2023)

Result: Mean central subfield thickness was 240.6 µm, mean macular thickness 275.9 µm and mean macular volume 9.9 mm3. Macular values showed no significant association with age except in the superior inner macula; boys had a significantly thicker central macula than girls. Mean RNFL thickness was 93.9 µm (the companion nerve-fibre metric — see the sibling shelf on peripapillary RNFL thickness, row S9-4-38).

Watch out: Paediatric, single-ethnicity Cirrus norms: useful as the second-platform limb, but children's values and this device's segmentation must not be carried into adult Spectralis practice.

Source: Raffa L et al. Saudi medical journal. 2023. PMID: 38016746. Registry ID: none in the record. MeSH: Humans · Male · Child · Female · Optic Disk/diagnostic imaging · Retinal Ganglion Cells · Reference Values · Tomography, Optical Coherence/methods · Retrospective Studies · Saudi Arabia · Nerve Fibers · Cross-Sectional Studies

Card 5 — Synthesis: healthy central subfield thickness is roughly 228-270 µm depending on the machine — Spectralis ~270 µm, Cirrus (children) ~241 µm, swept-source ~228 µm against 260 µm on spectral-domain in the same eyes

Study: Synthesis

Population: Synthesis of the four primary human studies above.

Summary: Synthesis: healthy central subfield thickness is roughly 228-270 µm depending on the machine — Spectralis ~270 µm, Cirrus (children) ~241 µm, swept-source ~228 µm against 260 µm on spectral-domain in the same eyes

Result: Framed by Ganong's account of retinal structure — thin textbook framing for OCT biometry, as the slate row states; the primary measurement literature carries this shelf. The convergent picture: on Spectralis, healthy central subfield thickness averages 270.2 µm (SD 22.5; N = 50) with a proposed normal ceiling of 315 µm, and no significant age or sex effect on total retinal thickness (Grover 2009). Paired same-eye measurement shows the number belongs to the device: swept-source read 227.8 µm where spectral-domain read 260.0 µm (Xiong 2021), and formal Spectralis-to-Cirrus conversion equations exist for layer thicknesses in a 546-person international cohort, which also sizes healthy ageing at -2.4 µm per decade (nerve fibre layer) and -1.4 µm per decade (ganglion cell layer) after age 40 (Kenney 2022). Cirrus paediatric norms (CSF 240.6 µm; Raffa 2023) complete the second-platform limb. The companion peripapillary RNFL shelf (slate row S9-4-38) homes the nerve-fibre metric; this shelf homes macular thickness only. PHYSIOLOGY — ESTABLISHED.

Watch out: Cross-platform conversion equations reduce but do not abolish device differences; percentile limits are normative-database constructs of each platform, not biological constants.

Source: Synthesis of Grover S et al. American journal of ophthalmology. 2009 (PMID: 19427616); Xiong K et al. Current eye research. 2021 (PMID: 33879001); Kenney R et al. Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society. 2022 (PMID: 36049213); Raffa L et al. Saudi medical journal. 2023 (PMID: 38016746). Textbook framing: Ganong's Review of Medical Physiology (vision / retinal structure).