SourceMed · Shelf #7183 in the ask interface

Colour discrimination peaks at 20-29 years, then 100-hue errors climb steadily — gathering on the blue-yellow axis, with lens yellowing carrying part of the rise

Shelf #7183 · Eyes, skin, nose & allergy

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 1991–2001.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans, how does colour discrimination change with age — Farnsworth–Munsell 100-hue total error scores by decade and the emergence of blue–yellow (tritan-like) errors — in people with no eye disease?

Balance of the evidence

Textbook framing: Ganong (colour vision); Guyton & Hall, ch. 50 (retinal colour mechanisms). In disease-free eyes, Farnsworth-Munsell 100-hue performance follows a shallow U across life, replicated on three continents: total error scores are lowest at 20-29 years (Huang 1993, N = 120), discrimination is best between 20 and 50 years (Roy 1991, N = 115, North America — norms comparable with Verriest's European data), and total scores as published rise from ~7.4-7.6 in youth to ~10.1-10.2 in the 60s, correlating significantly with age in both eyes (Mantyjarvi 2001, N = 160, Macbeth lamp at 1000 lux). The added errors concentrate on the blue-yellow (tritan) axis (Huang), and lens changes are significantly associated with higher scores alongside age (Roy) — so part of 'ageing' colour loss is lenticular. Sex and eye side do not matter. PHYSIOLOGY — ESTABLISHED.

MeSH: Adolescent · Adult · Aged · Aging/physiology · Child · Color Perception/physiology · Color Perception Tests · Female · Humans · Male · Middle Aged · Reference Values · Retinal Cone Photoreceptor Cells/physiology · Aged, 80 and over · Child, Preschool · North America · Reproducibility of Results · Retinal Diseases/physiopathology · Visual Acuity · Age Factors · Color Perception · Color Perception Tests/methods

Cards (4)

Card 1 — FM 100-hue norms in 160 healthy people aged 10-69: mean total scores rise from ~7.4-7.6 to ~10.1-10.2 across the age span (Mantyjarvi 2001)

Study: Primary human physiology study (FM 100-hue normative scores by age)

Population: 160 persons aged 10-69 years (106 women, 54 men) with healthy eyes, tested with the Farnsworth-Munsell 100-hue test under a Macbeth Easel lamp at 1000 lux, right eye first; results in six age groups (10-19 through 60-69 years).

Summary: FM 100-hue norms in 160 healthy people aged 10-69: mean total scores rise from ~7.4-7.6 to ~10.1-10.2 across the age span (Mantyjarvi 2001)

Result: Mean total scores in the right eye ranged from 7.44 (SD 2.46) to 10.07 (SD 2.03) across the six age groups, and in the left eye from 7.56 (SD 2.36) to 10.16 (SD 2.68) — scores as published by the author. Total score correlated significantly with age in both eyes (right R = 0.308, P = 0.0001; left R = 0.246, P = 0.0021). The author provides the age-group means and individual box scores as the reference for judging a patient's result normal or abnormal.

Watch out: Scores are as published by the author (mean totals ~7.4-10.2, a different scale from the raw total error scores reported by some laboratories) — do not compare them directly with raw-score norms from other laboratories; illumination (Macbeth lamp, 1000 lux) is part of the norm.

Source: Mantyjarvi M et al. Documenta ophthalmologica. Advances in ophthalmology. 2001. PMID: 11475367. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aging/physiology · Child · Color Perception/physiology · Color Perception Tests · Female · Humans · Male · Middle Aged · Reference Values · Retinal Cone Photoreceptor Cells/physiology

Card 2 — North American norms (N = 115, ages 5-81): colour discrimination is best at 20-50 years, and 100-hue errors rise with age and with lens changes (Roy 1991)

Study: Primary human physiology study (age-specific FM 100-hue and D-15 norms)

Population: 115 normal North American subjects aged 5-81 years given the Farnsworth-Munsell 100-hue test and the Lanthony Desaturated Panel D-15, to obtain age-specific norms for both procedures.

Summary: North American norms (N = 115, ages 5-81): colour discrimination is best at 20-50 years, and 100-hue errors rise with age and with lens changes (Roy 1991)

Result: For each test, colour discrimination was best between the ages of 20 and 50 years. Both increasing age and the occurrence of lens changes were significantly associated with increasing 100-hue error scores. The age-specific 100-hue norms were comparable with Verriest's European norms; norms for the desaturated D-15 were judged problematic because that test showed somewhat greater variability than the 100-hue.

Watch out: The fetched record gives the age pattern and the lens-change association without a numeric error-score table: the quantitative by-decade values on this shelf come from the Mantyjarvi and Huang cards.

Source: Roy MS et al. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 1991. PMID: 2044973. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Aging/physiology · Child · Child, Preschool · Color Perception/physiology · Color Perception Tests · Female · Humans · Male · Middle Aged · North America · Reference Values · Reproducibility of Results · Retinal Diseases/physiopathology · Visual Acuity

Card 3 — FM 100-hue in 120 normal subjects (240 eyes): total error score lowest at 20-29 years and rising gradually thereafter — partial errors grow around the tritan axis with age (Huang 1993)

Study: Primary human physiology study (FM 100-hue total and partial error scores by age group)

Population: 120 normal subjects aged 10-69 years (240 eyes), divided into six age groups, tested with the FM 100-hue test; total and partial error scores analysed by age, sex and eye.

Summary: FM 100-hue in 120 normal subjects (240 eyes): total error score lowest at 20-29 years and rising gradually thereafter — partial errors grow around the tritan axis with age (Huang 1993)

Result: Total error score did not differ significantly between males and females or between right and left eyes, but rose with age: it was lowest in the 20-29-year group and increased gradually with aging. Partial error scores showed the same pattern, with the larger partial errors appearing around the tritan axis as age increased — the blue-yellow axis along which age-related errors concentrate.

Watch out: A 1993 single-centre normative series reported in a regional journal: its value is the independent replication of the U-shaped age curve and the tritan-axis concentration, concordant with the Finnish and North American datasets.

Source: Huang S et al. Yan ke xue bao = Eye science. 1993. PMID: 8168612. Registry ID: none in the record. MeSH: Adolescent · Adult · Age Factors · Aged · Child · Color Perception · Color Perception Tests/methods · Female · Humans · Male · Middle Aged

Card 4 — Synthesis: FM 100-hue performance peaks in the third decade, worsens gradually thereafter, and the extra errors gather on the blue-yellow (tritan) axis — lens changes account for part of the rise

Study: Synthesis

Population: Synthesis of the three primary human studies above.

Summary: Synthesis: FM 100-hue performance peaks in the third decade, worsens gradually thereafter, and the extra errors gather on the blue-yellow (tritan) axis — lens changes account for part of the rise

Result: Framed by Ganong (colour vision) and Guyton & Hall (ch. 50, retinal colour mechanisms). Three independent normative datasets on three continents agree on the shape of ageing colour discrimination in disease-free eyes: error scores are lowest in the 20-29-year group (Huang 1993, N = 120), discrimination is best between 20 and 50 (Roy 1991, N = 115), and total scores as published climb from ~7.4-7.6 in youth to ~10.1-10.2 by the 60s with a significant age correlation in both eyes (Mantyjarvi 2001, N = 160). The errors are not random: partial error scores grow around the tritan (blue-yellow) axis with age (Huang), and lens changes are significantly associated with higher error scores alongside age itself (Roy) — the record supports separating a lenticular contribution from any neural one only to that extent. Sex and eye side do not matter (Huang; Mantyjarvi). Test illumination belongs on the face of any norm (Mantyjarvi used a Macbeth lamp at 1000 lux). PHYSIOLOGY — ESTABLISHED.

Watch out: Raw and author-transformed total error scores are both in circulation and are not interchangeable; a clinic's norms are valid only under comparable illumination and scoring.

Source: Synthesis of Mantyjarvi M et al. Documenta ophthalmologica. Advances in ophthalmology. 2001 (PMID: 11475367); Roy MS et al. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 1991 (PMID: 2044973); Huang S et al. Yan ke xue bao = Eye science. 1993 (PMID: 8168612). Textbook framing: Ganong's Review of Medical Physiology (colour vision); Guyton & Hall, ch. 50.