SourceMed · Shelf #7184 in the ask interface
Normal field sensitivity is flat to age 40, then falls — 5.5 dB peripherally by age 75 — while a healthy person's first-ever field runs ~4 dB low from learning alone
Shelf #7184 · Eyes, skin, nose & allergy
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1998–2010.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, how does automated static perimetry sensitivity fall with age — differential light sensitivity by eccentricity and decade (Octopus/Humphrey normative studies) — and how large is the learning effect between a first and second visual field?
Balance of the evidence
Textbook framing: Ganong (vision/visual pathways); Guyton & Hall, ch. 51. Automated static perimetry sensitivity is age-shaped and platform-bound. The Octopus 101 normative model (81 healthy subjects, 10-79 years) shows differential luminance sensitivity nearly constant from 10-40 years, then declining ever more steeply, the loss growing with eccentricity — 5.5 dB at 25° superiorly between ages 10 and 75 — with total random SD 1.75 dB (Hermann 2008). Across six field tests in 100 normal subjects, standard automated perimetry had the least ageing effect, practice effect and variability, and short-wavelength perimetry the most (Gardiner 2006); SWAP variability is 2.7× white-on-white and shrinks toward 1.9× after correcting for lens media absorption, which also flattens its age slope by ~25% (Wild 1998). The learning effect is large: naive healthy adults improved mean deviation from -7.40 to -3.29 dB over three FDT sessions, with 50-64% of first fields falsely classifying as abnormal (Pierre-Filho 2010). PHYSIOLOGY — ESTABLISHED.
MeSH: Adolescent · Adult · Aged · Aging/physiology · Child · Female · Humans · Male · Middle Aged · Models, Biological · Reference Values · Sensory Thresholds/physiology · Visual Field Tests/instrumentation,standards · Visual Fields/physiology · Aged, 80 and over · Contrast Sensitivity/physiology · Glaucoma/diagnosis,physiopathology · Prognosis · Visual Field Tests · Absorption · Light · Ocular Physiological Phenomena · Visual Field Tests/methods,statistics & numerical data · False Positive Reactions · Learning · Reproducibility of Results · Sensory Thresholds · Visual Field Tests/methods
Cards (5)
Card 1 — Octopus 101 normative model (81 healthy subjects, 10-79 years): sensitivity is flat from 10-40, then declines ever more steeply — 5.5 dB lost at 25° superiorly between ages 10 and 75 (Hermann 2008)
Study: Primary human physiology study (age-dependent Octopus normative DLS model)
Population: 81 eyes of 81 ophthalmologically healthy subjects (11-12 per decade, aged 10-79 years); automated static perimetry of the central 30° on the Octopus 101 (background 10 cd/m2), 68-point grid, 4-2-2 staircase; a smooth mathematical model was fitted to the differential luminance sensitivity (DLS) thresholds.
Summary: Octopus 101 normative model (81 healthy subjects, 10-79 years): sensitivity is flat from 10-40, then declines ever more steeply — 5.5 dB lost at 25° superiorly between ages 10 and 75 (Hermann 2008)
Result: The model fitted well (r2 = 0.74) with total random standard deviation 1.75 dB (1.5 dB centrally, below 1.25 dB in a ring around the centre, higher at the border). Average DLS varied quadratically with age: close to constant for ages 10-40 and declining ever more steeply thereafter. The age effect grew with eccentricity; the greatest drop was in the peripheral superior hemifield, where DLS at 25° eccentricity was estimated 5.5 dB higher in 10-year-olds than in 75-year-olds. The model predicts age-related normal thresholds for any location in the central 30°.
Watch out: Octopus 101 values with this staircase strategy: Humphrey decibel values are not numerically interchangeable, since background, stimulus and algorithm differ by platform.
Source: Hermann A et al. Acta ophthalmologica. 2008. PMID: 18070224. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aging/physiology · Child · Female · Humans · Male · Middle Aged · Models, Biological · Reference Values · Sensory Thresholds/physiology · Visual Field Tests/instrumentation,standards · Visual Fields/physiology
Card 2 — Six visual-field tests in 100 normal subjects (20-85 years): standard automated perimetry shows the least ageing effect, practice effect and variability; short-wavelength the most (Gardiner 2006)
Study: Primary human physiology study (age, practice and variability across six perimetric tests)
Population: 100 normal subjects aged 20-85 years tested with six procedures: standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), temporal modulation perimetry, frequency-doubling technology perimetry (FDT), detection acuity and resolution acuity perimetry; each test's results were normalised by its estimated dynamic range for direct comparison.
Summary: Six visual-field tests in 100 normal subjects (20-85 years): standard automated perimetry shows the least ageing effect, practice effect and variability; short-wavelength the most (Gardiner 2006)
Result: Of the three clinically common tests, SWAP exhibited the greatest aging and practice effects and test-retest variability, followed by FDT, with SAP exhibiting the least of all three. Resolution acuity perimetry was the most variable test overall, followed by temporal modulation perimetry. The authors conclude these differences must be taken into account when evaluating glaucomatous loss with different functional tests and when comparing their speed of detection.
Watch out: A comparative-methods study: it ranks the tests against each other rather than publishing a normative threshold table — the absolute Octopus norms come from the Hermann card.
Source: Gardiner SK et al. Optometry and vision science : official publication of the American Academy of Optometry. 2006. PMID: 16840869. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Aging/physiology · Contrast Sensitivity/physiology · Glaucoma/diagnosis,physiopathology · Humans · Middle Aged · Prognosis · Reference Values · Visual Field Tests · Visual Fields/physiology
Card 3 — Normal SWAP variability on the Humphrey (51 experienced normal subjects): interindividual variation 2.7× white-on-white — falling to 1.9× after correcting for ocular media absorption (Wild 1998)
Study: Primary human physiology study (normal variability and media effects in SWAP vs white-on-white perimetry)
Population: 51 normal subjects stratified by decade (mean age 55.5; range 24-83 years), experienced in both white-on-white (W-W) and short-wavelength automated perimetry (SWAP); one eye examined on three occasions with Humphrey Field Analyzer Program 30-2, Full Threshold and FASTPAC strategies; ocular media absorption (OMA) measured from scotopic sensitivity at 410 vs 560 nm.
Summary: Normal SWAP variability on the Humphrey (51 experienced normal subjects): interindividual variation 2.7× white-on-white — falling to 1.9× after correcting for ocular media absorption (Wild 1998)
Result: SWAP examinations took 15.0% (Full Threshold) and 16.8% (FASTPAC) longer than W-W. The gradient of age-decline in mean sensitivity for SWAP was about 25% less steep after correction for ocular media absorption than before — part of the apparent age loss is lens absorption, not neural loss. Interindividual normal variability (coefficient of variation) for SWAP was 2.7 times that of W-W perimetry uncorrected (range 2.0-3.9) and 1.9 times (range 1.4-2.9) after OMA correction, so a proportionately larger sensitivity drop is required before a SWAP field counts as abnormal.
Watch out: Experienced observers only, and a blue-on-yellow paradigm whose variability is intrinsically high: first-test SWAP fields in naive patients will vary more than these norms suggest.
Source: Wild JM et al. Investigative ophthalmology & visual science. 1998. PMID: 9430545. Registry ID: none in the record. MeSH: Absorption · Adult · Aged · Aged, 80 and over · Aging/physiology · Female · Humans · Light · Male · Middle Aged · Ocular Physiological Phenomena · Sensory Thresholds/physiology · Visual Field Tests/methods,statistics & numerical data · Visual Fields/physiology
Card 4 — Learning effect on Humphrey Matrix FDT (28 perimetry-naive healthy adults): mean deviation improves from -7.40 dB to -3.29 dB over three sessions — and half of first fields look 'abnormal' (Pierre-Filho 2010)
Study: Primary human physiology study (perimetric learning effect in naive healthy subjects)
Population: 28 healthy adults with no history of visual field testing; one eye tested three times with the Humphrey Matrix frequency-doubling perimeter, 24-2 programme, full-threshold strategy; sessions compared for duration, indices and abnormal-point counts against Anderson's criteria.
Summary: Learning effect on Humphrey Matrix FDT (28 perimetry-naive healthy adults): mean deviation improves from -7.40 dB to -3.29 dB over three sessions — and half of first fields look 'abnormal' (Pierre-Filho 2010)
Result: Mean deviation improved from -7.40 dB (SD 1.49) at the first session to -4.64 dB (SD 0.97) at the second and -3.29 dB (SD 0.93) at the third; pattern standard deviation fell significantly with repetition (P < 0.01), as did test duration, fixation losses, false negatives and abnormal-point counts (P < 0.05). False-positive 'abnormal' classifications ranged 50-64% at the first session, 29-54% at the second and 18-32% at the third. The authors conclude the learning effect must be considered in normal individuals with no perimetric experience.
Watch out: FDT Matrix values, not standard white-on-white thresholds — but the lesson generalises: a first-ever field in a healthy person is systematically depressed and often flags abnormal, so normative comparisons assume a practised observer.
Source: Pierre-Filho Pde T et al. Eye (London, England). 2010. PMID: 19680272. Registry ID: none in the record. MeSH: Adult · False Positive Reactions · Female · Humans · Learning · Male · Middle Aged · Reproducibility of Results · Sensory Thresholds · Visual Field Tests/methods · Visual Fields/physiology
Card 5 — Synthesis: normal perimetric sensitivity holds to ~40 years, then falls — fastest peripherally (5.5 dB by age 75 at 25° superiorly) — and a first field in a naive healthy eye is depressed by ~4 dB of pure learning
Study: Synthesis
Population: Synthesis of the four primary human studies above.
Summary: Synthesis: normal perimetric sensitivity holds to ~40 years, then falls — fastest peripherally (5.5 dB by age 75 at 25° superiorly) — and a first field in a naive healthy eye is depressed by ~4 dB of pure learning
Result: Framed by Ganong (vision/visual pathways) and Guyton & Hall (ch. 51). The Octopus normative model (N = 81) sets the shape: differential light sensitivity is nearly constant from 10-40 years, then declines with accelerating slope, the loss growing with eccentricity to 5.5 dB at 25° in the superior field between ages 10 and 75, with total random SD 1.75 dB (Hermann 2008). Platform matters: among six tests in 100 normal subjects, standard automated perimetry showed the least ageing, practice effect and variability, and short-wavelength perimetry the most (Gardiner 2006); SWAP's interindividual variability is 2.7× white-on-white, and correcting for ocular media absorption flattens its apparent age slope by ~25% — part of 'ageing' field loss is lens (Wild 1998). Superimposed on all of it is learning: naive healthy subjects improved mean deviation by ~4.1 dB over three FDT sessions while false-positive abnormal classifications fell from 50-64% to 18-32% (Pierre-Filho 2010). Values are platform- and strategy-specific and are carded as such. PHYSIOLOGY — ESTABLISHED.
Watch out: Normative databases assume experienced, reliable observers and a specified platform/strategy; applying Octopus norms to Humphrey fields, or either to a patient's first-ever field, manufactures 'defects' out of learning and lens.
Source: Synthesis of Hermann A et al. Acta ophthalmologica. 2008 (PMID: 18070224); Gardiner SK et al. Optometry and vision science : official publication of the American Academy of Optometry. 2006 (PMID: 16840869); Wild JM et al. Investigative ophthalmology & visual science. 1998 (PMID: 9430545); Pierre-Filho Pde T et al. Eye (London, England). 2010 (PMID: 19680272). Textbook framing: Ganong's Review of Medical Physiology (vision); Guyton & Hall, ch. 51.