SourceMed · Shelf #7250 in the ask interface
TEOAE norms in young adults: larger in women and in Chinese ears, absent in 5 of 186 otologically normal ears, and linear protocols give better SNR than non-linear
Shelf #7250 · Eyes, skin, nose & allergy
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 2000–2008.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In normal-hearing young adults, what are transient-evoked otoacoustic emission (TEOAE) amplitudes, whole-response reproducibility and signal-to-noise ratios — by sex, ear and ethnic group — and in what fraction of otologically normal ears is no response recordable despite normal hearing?
Balance of the evidence
Textbook framing: Ganong, hearing (cochlear mechanics) — thin framing, and this shelf rests chiefly on the primary test-norming literature, and says so. Three adult datasets: a representative population sample aged 18-25 (345 adults; norms from 186 otologically normal ears, including the distributional fact that 5 normal ears had no recordable response despite thresholds better than 20 dB), a sex-and-ethnic-group comparison (81 Caucasian + 81 Chinese young adults; amplitude higher in women and in Chinese ears at equal hearing sensitivity), and a protocol study (42 adults; post-processed linear recordings superior on noise, SNR and reproducibility, with tolerance-interval scoring criteria). TEOAE is kept separate from DPOAE (shelf #7249): a click-evoked whole-cochlea response is not a frequency-specific DP-gram. PHYSIOLOGY — ESTABLISHED.
MeSH: Acoustic Impedance Tests · Acoustic Stimulation · Adolescent · Adult · Age Factors · Audiometry, Pure-Tone · Auditory Threshold/physiology · Cochlea/physiology · Female · Humans · Male · Noise/adverse effects · Ocular Physiological Phenomena · Otoacoustic Emissions, Spontaneous/physiology · Sex Factors · Asian People/statistics & numerical data · Audiometry, Pure-Tone/statistics & numerical data · Auditory Threshold · Ear, Middle/physiology · Evoked Potentials, Auditory · Hearing/physiology · White People/statistics & numerical data · Linear Models · Noise · Nonlinear Dynamics
Cards (4)
Card 1 — Population sample aged 18-25 (345 adults, 688 ears): TEOAE norms from 186 otologically normal ears — and 5 normal ears with no recordable response despite thresholds better than 20 dB (Ferguson 2000)
Study: Primary human physiology study (population TEOAE normative sample, ILO88 non-linear mode)
Population: Representative population sample of 345 young adults aged 18-25 years (688 ears); transient-evoked otoacoustic emissions obtained with the Otodynamics ILO88 in standard non-linear mode; normative data presented for the 186 otologically normal (ON) ears.
Summary: Population sample aged 18-25 (345 adults, 688 ears): TEOAE norms from 186 otologically normal ears — and 5 normal ears with no recordable response despite thresholds better than 20 dB (Ferguson 2000)
Result: In 5 ON ears there was no recordable TEOAE response despite hearing threshold levels better than 20 dB — an absent TEOAE is a distributional fact in normal ears, not proof of pathology. The main factors affecting TEOAE level were: (1) gender — females had larger responses on average than males; (2) tympanometric measures — ears with entirely normal tympanometry had larger responses than ears with minor tympanometric abnormalities; (3) click stimulus intensity in the ear canal, correlating positively with TEOAE level; and (4) hearing threshold at 0.5 kHz, correlating negatively with amplitude. Social noise exposure had a small effect at 2 kHz (lower response in the exposed).
Watch out: Norms are for the ILO88 non-linear click protocol in 18-25-year-olds: TEOAE level is partly a middle-ear and stimulus-level measurement (tympanometry, in-canal click intensity), not a pure cochlear number.
Source: Ferguson MA et al. Transient-evoked otoacoustic emissions in a representative population sample aged 18 to 25 years. Audiology : official organ of the International Society of Audiology. 2000. PMID: 10905398. Registry ID: none in the record. MeSH: Acoustic Impedance Tests · Acoustic Stimulation · Adolescent · Adult · Age Factors · Audiometry, Pure-Tone · Auditory Threshold/physiology · Cochlea/physiology · Female · Humans · Male · Noise/adverse effects · Ocular Physiological Phenomena · Otoacoustic Emissions, Spontaneous/physiology · Sex Factors
Card 2 — TEOAE amplitude is higher in women than men and in Chinese than Caucasian young adults (81 + 81 normal-hearing adults) — with no racial difference in hearing sensitivity (Shahnaz 2008)
Study: Primary human physiology study (TEOAE by sex and ethnic group, normal-hearing young adults)
Population: 81 Caucasian (mean age 27.8 years) and 81 Chinese (mean age 24.7 years) young adults with normal hearing; TEOAE amplitude, noise levels and hearing thresholds compared by race and gender in a single-author normative study.
Summary: TEOAE amplitude is higher in women than men and in Chinese than Caucasian young adults (81 + 81 normal-hearing adults) — with no racial difference in hearing sensitivity (Shahnaz 2008)
Result: TEOAE amplitude was significantly higher in females than in males and significantly higher in the Chinese group than the Caucasian group. Females had better hearing sensitivity than males, consistent with the TEOAE results; hearing sensitivity did not differ statistically between the racial groups, although the race-by-threshold interaction was significant. Noise levels did not differ between racial groups, so the author attributes the amplitude differences most likely to middle-ear transmission properties or cochlear mechanisms.
Watch out: Group mean differences are not individual diagnostic limits: a lower TEOAE in a Caucasian man may be entirely normal for his group — norms must be read against sex- and population-matched references.
Source: Shahnaz N. Transient evoked otoacoustic emissions (TEOAEs) in Caucasian and Chinese young adults. International journal of audiology. 2008. PMID: 18236238. Registry ID: none in the record. MeSH: Adolescent · Adult · Asian People/statistics & numerical data · Audiometry, Pure-Tone/statistics & numerical data · Auditory Threshold · Ear, Middle/physiology · Evoked Potentials, Auditory · Female · Hearing/physiology · Humans · Male · White People/statistics & numerical data
Card 3 — Linear vs non-linear TEOAE protocols (normative database, 42 adults): post-processed linear recordings give lower noise, superior SNR and higher reproducibility — with normative scoring criteria at 2 and 3 kHz (Hatzopoulos 2003)
Study: Primary human physiology study (TEOAE recording-protocol normative database)
Population: 42 adult subjects serving as a normative database; TEOAE responses elicited by clicks at average intensities of 72 dB p.e. SPL (linear protocol) and 84 dB p.e. SPL (non-linear protocol); stimulus artefact in linear recordings suppressed by a window function (3.8-13.8 ms) and a high-pass filter at 830 Hz; repeated-measures comparison of response, noise, correlation and SNR at 1.0-5.0 kHz.
Summary: Linear vs non-linear TEOAE protocols (normative database, 42 adults): post-processed linear recordings give lower noise, superior SNR and higher reproducibility — with normative scoring criteria at 2 and 3 kHz (Hatzopoulos 2003)
Result: Unprocessed early segments (3.2-5.2 ms) of linear and non-linear responses had highly similar contours with no statistically significant mean differences. After post-processing, linear recordings showed significantly lower noise levels (and thus superior SNRs) and higher reproducibility values than non-linear recordings. Normative adult scoring criteria were calculated from free-distribution tolerance intervals for the TEOAE correlation and the SNRs at 2.0 and 3.0 kHz.
Watch out: Protocol is destiny: linear and non-linear clicks at different intensities (72 vs 84 dB p.e. SPL) yield different noise and SNR norms — a clinic's pass criteria belong to the protocol that generated them.
Source: Hatzopoulos S et al. TEOAE recording protocols revised: data from adult subjects. International journal of audiology. 2003. PMID: 14570242. Registry ID: none in the record. MeSH: Acoustic Stimulation · Adult · Female · Hearing/physiology · Humans · Linear Models · Male · Noise · Nonlinear Dynamics · Otoacoustic Emissions, Spontaneous/physiology
Card 4 — Synthesis: in young adults TEOAEs are larger in women and in Chinese than Caucasian ears, absent in a small fraction of otologically normal ears (5 of 186), and protocol-dependent — linear recordings beat non-linear on noise, SNR and reproducibility
Study: Synthesis
Population: Synthesis of the three primary reports carded above.
Summary: Synthesis: in young adults TEOAEs are larger in women and in Chinese than Caucasian ears, absent in a small fraction of otologically normal ears (5 of 186), and protocol-dependent — linear recordings beat non-linear on noise, SNR and reproducibility
Result: Framed by Ganong (hearing — cochlear mechanics; brief framing, the primary test-norming literature carries this shelf). The population anchor is the representative 18-25 sample: norms from 186 otologically normal ears, with 5 normal ears showing no recordable response despite thresholds better than 20 dB, and level driven by sex, tympanometry, in-canal click intensity and 0.5 kHz threshold (Ferguson 2000). Sex and population shift the distribution itself — amplitude higher in women and in Chinese than Caucasian adults at equal hearing sensitivity (Shahnaz 2008, 81 + 81). Protocol shifts it too: post-processed linear recordings give lower noise, superior SNR and higher reproducibility than the standard non-linear mode, with tolerance-interval scoring criteria at 2 and 3 kHz (Hatzopoulos 2003, N = 42). TEOAE (click-evoked, whole-cochlea) is a different measurement from the frequency-specific DPOAE DP-gram on companion shelf #7249 — carded separately. PHYSIOLOGY — ESTABLISHED.
Watch out: An absent TEOAE in a normal-hearing young adult is uncommon but documented (5 of 186 otologically normal ears): absence alone, with a normal audiogram and tympanogram, is a finding to repeat under the same protocol, not a diagnosis.
Source: Synthesis of the reports carded above; no additional source.